![Sandel MT102 Installation Manual Download Page 39](http://html.mh-extra.com/html/sandel/mt102/mt102_installation-manual_807003039.webp)
Appendix D: Sample Airplane Flight Manual Supplement
82011-IM, REV J
Sandel SG102 & MT102 Installation Manual
Page 12-2
SECTION IV NORMAL PROCEDURES
The circuit breaker for the SG102 is located on the (right/left) circuit breaker panel labeled
AHRS.
While the SG102 is initializing the aircraft should not be moved. When the Flag is removed
from the heading display, the SG102 initialization is complete.
The SG102 is normally be operated in the slaved mode. If it is desired to operate in the
unslaved mode, select the Slaving Off position on the mode selector switch. Adjust the heading
clockwise or counter clockwise as needed using the manual slew switches. All heading
outputs will track the new heading. Selecting Slaving On will return all heading outputs to the
current magnetic heading and restore slaving operation.
If the SG102 fails to operate or the display indicates that the heading is invalid, use the aircraft
compass and/or other available heading source for heading information.
SECTION V PERFORMANCE DATA
No Change to AFM.