S&C TripSaver II Pairing Manual Download Page 6

6    S&C Instruction Sheet 461-521

Shipping and Handling

Packing

A complete TripSaver  II Cutout-Mounted Recloser for a 
new installation consists of two shipping containers. They 
include the following: 
•  A single-pole TripSaver II Cutout-Mounted Recloser
•  A mounting and miscellaneous mounting hardware for 

securing the TripSaver II recloser to the pole

A complete TripSaver II Communications via Gateway 
system for a new installation consists of two shipping 
containers. They include the following:
•  The communications gateway (including radio, if speci-

fied “factory-furnished” at time of order), an optional 
battery if specified, and mounting hardware for securing 
the box to the pole 

•  An ac power cable

Inspection

Examine the shipment for external evidence of damage as 
soon after receipt as possible, preferably before removal 
from the carrier’s conveyance. Check the bill of lading to 
make sure the listed shipping containers are present:

If there is visible loss and/or damage:

1.  Notify the delivering carrier immediately.
2.  Ask for a carrier inspection.
3.  Note the condition of shipment on all copies of the 

delivery receipt.

4.  File a claim with the carrier.

If concealed damage is discovered:

1.  Notify the delivering carrier within 15 days of receipt of 

shipment.

2.  Ask for a carrier inspection.
3.  File a claim with the carrier.

Also, notify S&C Electric Company in all instances of 

loss and/or damage.

Handling

NOTICE

DO NOT drop a TripSaver II recloser or subject any 
of its parts to undue stress during installation . Only 
remove a TripSaver II recloser from the carton when 
you are ready for installation .

Storage

TripSaver II Cutout-Mounted Reclosers and TripSaver II 
Communications Gateways are shipped on pallets banded 
with plastic wrap. This packaging is designed to protect 
the TripSaver II reclosers and Communications Gateways 
from freight damage. This packaging is not suitable for 
outdoor storage as it can trap water and moisture that 
may damage the equipment. After receipt, TripSaver II 
reclosers and TripSaver II Communications Gateways 
should be stored indoors in their shipping packaging. 
Storing TripSaver II reclosers or Communications 
Gateways outdoors in the shipping packaging will void 
the warranty.

Returning

If for any reason a TripSaver II recloser or TripSaver II 
Communications Gateway is to be returned, place it in 
the original shipping carton to prevent damage during 
shipping. If you need additional shipping cartons, contact 
your nearest S&C Sales Office, S&C Authorized Distributer, 
or S&C Headquarters.

Equipment Required

To perform the procedures detailed in this instruction 
sheet, you will need:
•  A TripSaver II Cutout-Mounted Recloser with the 

Extended Open Interval

 (“-O”) option

•  A TripSaver II Communications Gateway with battery 

backup

•  The TripSaver II Service Center Configuration Software 

installed on a PC

•  The TripSaver II Service Center Configuration Kit 

including the power module, ac cord, and USB trans-
ceiver

•  The S&C Magnet Tool (or equivalent strong magnet)
•  An Ethernet cable

Summary of Contents for TripSaver II

Page 1: ...rstanding Safety Alert Messages 3 Following Safety Instructions 3 Replacement Instructions and Labels 3 Location of Safety Labels 4 Safety Precautions 5 Shipping and Handling Packing 6 Inspection 6 Ha...

Page 2: ...ns Gateway Designate a location where you can easily retrieve and refer to this publication Proper Application WARNING The equipment in this publication is only intended for a specific application The...

Page 3: ...recautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions I...

Page 4: ...for Safety Labels Location Safety Alert Message Description Part Number A DANGER TripSaver II may be energized from either side and in any position G 9473 E B CAUTION This control is connected to ele...

Page 5: ...ctric shock and death DANGER The TripSaver II Cutout Mounted Recloser operates at high voltage Failure to observe these precautions will result in serious personal injury or death Some of these precau...

Page 6: ...TICE DO NOT drop a TripSaver II recloser or subject any of its parts to undue stress during installation Only remove a TripSaver II recloser from the carton when you are ready for installation Storage...

Page 7: ...rvice center configuration software Overview BeforepairingaTripSaverIICutout MountedRecloserwithaTripSaverIICommunications Gateway it must be placed in Gateway mode at the service center To enable Gat...

Page 8: ...s Gateway with a PC Ethernet cable Figure 2 Connect an Ethernet cable to the gateway controller module STEP 2 The communications gateway is accessed using a web browser interface The defaultconfigurat...

Page 9: ...from the command prompt With the CAT5 cable attached to communications gateway Ethernet Port 1 launch a Web browser on the PC Within the URL address line type in the communications gateway default IP...

Page 10: ...h firmware version 1 6 or 1 7 pairing can only be performed with the TripSaver II recloser powered by line current or an external power source not supplied by S C For details on the specifications for...

Page 11: ...asily paired in the service center without the requirement of line current or an external power source using the corded power module and ac adapter from the service center configuration kit STEP 1 Pla...

Page 12: ...e 9 This will turn on communications inside the TripSaver II recloser allowing it to be paired with the communications gateway Figure 9 Attach the magnet tool to the green logo STEP 4 Navigate to the...

Page 13: ...n be used at the installation site on TripSaver II reclosers furnished with firmware version 1 8 installed on the utility pole and NOT powered by line current by using the cordless power module to sup...

Page 14: ...on the Device Management screen STEP 2 With the recloser removed from the utility pole connect to the TripSaver II recloser using the service center configuration software and the service center confi...

Page 15: ...rvice center configuration software can be found in S C Instruction Sheet 461 504 STEP 4 Navigate to the Communication Settings menu and click on the Communication Mode dropdown box Change the Communi...

Reviews: