S&C Instruction Sheet 461-521    3

 Safety Information

Understanding  

Safety-Alert 

Messages

Several types of safety-alert messages may appear throughout this instruction sheet and 
on labels and tags attached to the TripSaver II Cutout-Mounted Recloser and TripSaver 
II Communications Gateway. Familiarize yourself with these types of messages and the 
importance of these various signal words: 

 DANGER

“DANGER” identifies the most serious and immediate hazards that will likely result in 
serious personal injury or death if instructions, including recommended precautions, 
are not followed .

 WARNING

“WARNING” identifies hazards or unsafe practices that can result in serious personal 
injury or death if instructions, including recommended precautions, are not followed .

 CAUTION

“CAUTION” identifies hazards or unsafe practices that can result in minor personal 
injury if instructions, including recommended precautions, are not followed .

NOTICE

“NOTICE” identifies important procedures or requirements that can result in product 
or property damage if instructions are not followed .

Following Safety 

Instructions

If you do not understand any portion of this instruction sheet and need assistance, contact 
your nearest S&C Sales Office or S&C Authorized Distributor. Their telephone numbers 
are listed on S&C’s website 

sandc.com

, or call the S&C Global Support and Monitoring 

Center at 1-888-762-1100.

NOTICE

Read this instruction sheet thoroughly and carefully 
before pairing the TripSaver II Cutout-Mounted Recloser  
with the TripSaver II Communications Gateway . 

Replacement 

Instructions  

and Labels

If additional copies of this instruction sheet are needed, contact your nearest S&C Sales 
Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd.

It is important that any missing, damaged, or faded labels on the equipment be replaced 

immediately. Replacement labels are available by contacting your nearest S&C Sales 
Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd.

Summary of Contents for TripSaver II

Page 1: ...rstanding Safety Alert Messages 3 Following Safety Instructions 3 Replacement Instructions and Labels 3 Location of Safety Labels 4 Safety Precautions 5 Shipping and Handling Packing 6 Inspection 6 Ha...

Page 2: ...ns Gateway Designate a location where you can easily retrieve and refer to this publication Proper Application WARNING The equipment in this publication is only intended for a specific application The...

Page 3: ...recautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions I...

Page 4: ...for Safety Labels Location Safety Alert Message Description Part Number A DANGER TripSaver II may be energized from either side and in any position G 9473 E B CAUTION This control is connected to ele...

Page 5: ...ctric shock and death DANGER The TripSaver II Cutout Mounted Recloser operates at high voltage Failure to observe these precautions will result in serious personal injury or death Some of these precau...

Page 6: ...TICE DO NOT drop a TripSaver II recloser or subject any of its parts to undue stress during installation Only remove a TripSaver II recloser from the carton when you are ready for installation Storage...

Page 7: ...rvice center configuration software Overview BeforepairingaTripSaverIICutout MountedRecloserwithaTripSaverIICommunications Gateway it must be placed in Gateway mode at the service center To enable Gat...

Page 8: ...s Gateway with a PC Ethernet cable Figure 2 Connect an Ethernet cable to the gateway controller module STEP 2 The communications gateway is accessed using a web browser interface The defaultconfigurat...

Page 9: ...from the command prompt With the CAT5 cable attached to communications gateway Ethernet Port 1 launch a Web browser on the PC Within the URL address line type in the communications gateway default IP...

Page 10: ...h firmware version 1 6 or 1 7 pairing can only be performed with the TripSaver II recloser powered by line current or an external power source not supplied by S C For details on the specifications for...

Page 11: ...asily paired in the service center without the requirement of line current or an external power source using the corded power module and ac adapter from the service center configuration kit STEP 1 Pla...

Page 12: ...e 9 This will turn on communications inside the TripSaver II recloser allowing it to be paired with the communications gateway Figure 9 Attach the magnet tool to the green logo STEP 4 Navigate to the...

Page 13: ...n be used at the installation site on TripSaver II reclosers furnished with firmware version 1 8 installed on the utility pole and NOT powered by line current by using the cordless power module to sup...

Page 14: ...on the Device Management screen STEP 2 With the recloser removed from the utility pole connect to the TripSaver II recloser using the service center configuration software and the service center confi...

Page 15: ...rvice center configuration software can be found in S C Instruction Sheet 461 504 STEP 4 Navigate to the Communication Settings menu and click on the Communication Mode dropdown box Change the Communi...

Reviews: