NB5 Tracker Installation 

Note: The device must be fully charged prior to installation. Remember to wear a pair of socks for comfortable 

attaching.   

1.

 

Circle the user’s leg with strap and 

installation height of NB5 will be 8-10cm 

from an outer ankle.   

 

 

 

2.

 

Circle  the  user’s  leg  with  strap  and 

determine  the  length  of  the  strap  that 

leaves  approximately  20-30  mm  (2-3 

scales)  of  space  between  the  use’s  leg 

and the strap for comfortable to wear.

   

3.

 

For example, Back Cover Edge Line is at 

the block 14; you should cut the block 16 

which is spare space for the strap clip.

 

 

4.

 

Use  the  specific  cutting  tool  to  cut  the 

strap not the scissors. 

Please refer to the document of cutting 

tool below. 

Use the dedicated strap cutter to cut the 

strap  to  corresponded  length  as 

measured at step 2. 

 

Note:   

The cut edge of strap should be flat to 

have  good  contact  of  fiber  optical 

detection. 

 

 

Cutting 
line   

Back Cover 
Edge Line   

Summary of Contents for NB-5

Page 1: ...0 San Jose Technology Inc All Rights Reserved This document contains information that is the property of SANAV This document may not be copied reproduced reduced to any electronic medium or machine re...

Page 2: ...P 6 Set up APN for 3G Service 23 STEP 7 Set up URL and TCP UDP IP Address 24 STEP 8 Set up Route for Data Transmission 26 STEP 9 Set up Auto Report Optional 27 Step 10 Request IMEI Number 28 Appendix...

Page 3: ...m Cold Cold Warm 26 seconds Hot 1 second Position Accuracy 2 5 meter CEP 50 24 hours static 130dBm SEP 3 5m RF RF Module RIFO TI CC1101 Modulation FSK Frequency 436 8MHz Sensitivity 116dBm 0 6kbaud Sy...

Page 4: ...ntaining latitude longitude date and time to assigned monitoring center It is specially designed for the intensive tracking applications such as offender tracking or life security Note In the house pl...

Page 5: ...light will stay on 2 GSM LED Red While the device gets GSM fixed or in normal operation the GSM light will flash every 3 seconds In case of weak GPS signal the GSM LED will flash every second When GSM...

Page 6: ...hnologies Corp All specifications subject to change without notice www sanav com www unictron com charged the CH LED will stay on Unplug the charger when the device is fully charged In this situation...

Page 7: ...Dist New Taipei City 236 Taiwan R O C Tel 886 2 22694456 Fax 886 2 22694451 service unictron com 7 Unictron Technologies Corp All specifications subject to change without notice www sanav com www unic...

Page 8: ...cm from an outer ankle 2 Circle the user s leg with strap and determine the length of the strap that leaves approximately 20 30 mm 2 3 scales of space between the use s leg and the strap for comfortab...

Page 9: ...and wearing purpose 6 While cutting the strap by using the dedicated strap it should proceed with 3 stages cutting procedures Keep cutter and strap at 90 degree angle to make sure that the cutting ed...

Page 10: ...hout notice www sanav com www unictron com 7 Cut procedures are completed 8 Put up the Jelly cover at the end of strap Please refer to NB5 Jelly cover assembly SOP 9 Fix the strap clip at the end of s...

Page 11: ...orp All specifications subject to change without notice www sanav com www unictron com 11 Activated Start tracking 12 While using wall charger aim the charger connector female to NB5 charge socket mal...

Page 12: ...tron Technologies Corp All specifications subject to change without notice www sanav com www unictron com Cutting Tools 1 Make sure that the front side of the cutting tool faces to you and that the st...

Page 13: ...ject to change without notice www sanav com www unictron com 3 After making sure the location is right push the top of cutting tool to cut the strap 4 Exchange the blade if needed Release the screw an...

Page 14: ...n com 14 Unictron Technologies Corp All specifications subject to change without notice www sanav com www unictron com 5 Install the blade Please make sure the edge of the blade is inside the white ar...

Page 15: ...pdate setting only when the password username and setup command are all correct If the command is not valid a failure report is going to be sent to the user s cell phone 6 If the device set up the aut...

Page 16: ...0 19 1 1 0 means to disable it The 1st parameter is for toggling the buzz alarm function The 2nd is for toggling the vibration alarm function 2 Once the events are triggered deactivate all alarm by se...

Page 17: ...username to a new user name abc Only enter new command with new user name after it has been changed Setup format username Password Function Code New username Example username 0000 1 abc SMS Text Desc...

Page 18: ...password 1111 Only enter command with new password will be valid for setting change after it has been changed Setup format username Password Function Code new Password new Password Example username 0...

Page 19: ...or something The maximum set of Security Phone Number is 3 We can simply set up one number or two numbers as well Setup format User Name Password Function Mode Security Number1 Security Number2 Securi...

Page 20: ...3 00 A 2457 80794 N 12125 53854 E 0 012 170720 A 67 AUTO I0200 9999 M14 4182mV 33 1 48 466 1 24A5 13E16E9 30 FFFF 29 10613 26 19 FFFF 195 10613 26 19 NB5 s HA ID is for the purpose that user can quick...

Page 21: ...types of command the short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode rf433 0 1 Detectio...

Page 22: ...umber of set of equipments in the same place such as more than 10 sets we can set them in groups and configure each set to different channel and it will reduce the possibility of disturbing each other...

Page 23: ...re not required just leave the parameters empty no space User can follow the Setup Format below to setup the APN that is provided by your GSM carrier Setup Format username Password Function Mode APN n...

Page 24: ...nction code 4 to setup the URL as the following command to configure URL for HTTP Setup Format User Name Password Function Mode 4 URL Example username 0000 4 http www sanavtw com uploadM1 php SMS Text...

Page 25: ...tup Format User Name Password Function Mode TCP IP Address Port Example username 0000 18 202 39 31 127 13337 SMS Text Description Start sign username Default ID of Bracelet If you have changed the Use...

Page 26: ...PS data by SMS message format to Cellular phone that has been set in Phone Book User can choose the route to transmit the data by HTTP TCP SMS protocol individually or with SMS message as a backup rou...

Page 27: ...he following example it will send a report every 1 minute 60 seconds and the total number of reports is 10 Setup Format User Name Password Function Mode intervals sec Number of Reports Example usernam...

Page 28: ...ion a unique number for identifying mobile devices validity in GSM network As above stated each device has a unique IMEI number Entering the SMS command as the following allows user to check the IMEI...

Page 29: ...a unique number for identifying mobile devices validity in GSM network 2 Main GPRMC Sentence 1 081219 00 time of fix UTC 2 A GPS fix status A GPS fix V GPS no fix 3 2457 80821 N 12125 53897 E Latitud...

Page 30: ...ts 17 RSCP Level Received Signal Code Power expressed in dBm levels 0 less than 115 dBm 1 90 from 115 dBm to 26 dBm with 1 dBm steps 91 25 dBm 18 Reserved FFFF 19 scrambling_code Scrambling code The r...

Page 31: ...is greater than AUTO the AUTO report will suspend The AUTO report recovers until the Alarm OFF command has been sent and the Alarm status ends POLL When the device has received the POLL command the P...

Page 32: ...note that all the characters which include and comma should be HALFWIDTH form 11 Please be aware of the upper capital lower cases when entering the SMS command 12 While entering any SMS command note t...

Page 33: ...immediately and then you can use this command Please make sure that those reports in flash won t be needed anymore before you use it Setup Format User Name Password Function Mode er Example username 0...

Page 34: ...sername 0000 rst now Table Restart Format Description Table Restart Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username pleas...

Page 35: ...0000 rst cfg 6 Table Restart Setting Format Description Table Setting Restart Response Description SMS Text Description Start sign username Default user name of the device If you have changed the use...

Page 36: ...command the POLL message will be sent to the server depending on the route you ve set The POLL message will be shown in the Event field of the report Setup Format User Name Password Function Mode 10...

Page 37: ...here are two types of command the short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode fbr 0...

Page 38: ...short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode reed 0 1 On OFF Example username 0000 re...

Page 39: ...n OFF 1 Interval of beep sound 180 Interval of vibration Example username 0000 19 1 1 1 180 SMS Text Description Start sign username Default ID of BRACELET If you have changed the Username please use...

Page 40: ...tion Message Reply Buzzer setup succeed username setup OK Device buzzer is turned off on Vibrator setup succeed username vibration motor is disabled enabled Buzzer and Vibrator setup scceed username s...

Page 41: ...er Saving Mode to 1 to disable it such like this command username 0000 combo 1 Setup Format User Name Password Function Mode Power Saving Mode Command username 0000 combo 3 Table Power Save Mode Setup...

Page 42: ...ername 0000 aes 1 Table AES128 encryption Setup Format Description Situation Description Success username setup OK Device data for aes128 protection is switched off on fail username command error Tabl...

Page 43: ...Mode Command username 0000 tcpack 1 Table TCP acknowledge Setup Format Description Situation Description Success username setup OK Device tcp ack mode is updated fail username command error Table TCP...

Page 44: ...le Low Power Setup Description Table Low Power Setup Response Description SMS COTA Command Description Start sign UserName Default ID of the device If you have changed the user name please use the upd...

Page 45: ...cellid 1 SMS COTA Command Description Start sign UserName Default ID of the device If you have changed the user name please use the updated one 0000 Default password If you have changed the password...

Page 46: ...anged the user name please use the updated one 0000 Default password If you have changed the password please use the updated one Function Code Code fota defines the firmware upgrade function URL of fi...

Page 47: ...e the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio...