11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456
|
Fax: 886-2-22694451
|
25
www.etek.com.tw
©
U
n
ic
tr
on
T
ec
h
n
olo
gie
s C
or
p
.
A
ll
spe
cif
ic
at
io
n
s
su
bje
ct
to
c
h
an
g
e
w
ith
ou
t n
oti
ce
.
www.sanav.com
www.unictron.com
Set up TCP/UDP IP Address
This SMS command is for setting up a specified TCP or UDP protocol based server where the bracelet will
transmit GPS (GPRMC) positioning data for real time GPS tracking as route of the device is set as TCP or UDP
mode.
E.g. Use function code 18 to setup the URL as the following command to configure URL for TCP or UDP.
Setup Format
:
#<User Name>,<Password>,<Function Mode>,<TCP/IP Address
>:<
Port
>
*
Example
:
#username,0000,18,202.39.31.127:13337*
SMS Text
Description
#
Start sign.
username
Default ID of Bracelet.
If you have changed the Username, please use the updated one.
0000
Default password of Bracelet.
If you have changed the password, please use the updated one.
18
Mode 18 defines IP address setup mode for TCP or UDP.
202.39.31.127:1337
The specified TCP/UDP IP address and port.
*
End sign.
Table: TCP/UDP IP Address Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] +", setup ok. Device TCP/IP is updated."
Setup Fail
[username] +", TCP/IP setup fail!"
Incorrect username or
password
[username] + Username or Password error
Incorrect function mode
[username] + command error
Table: TCP/UDP IP Address Setup Response Description