Command for Toggling the Buzzer and vibrator
When the Alarm events (such as ST, DT, Geo-fence event) are triggered, the device will beep and vibrate for
notice as well as send the reports.
This command is to toggling the beep sound and vibration respectively and configuring the interval of notice.
This command only affects the beep sound and vibration when the Alarm events are triggered.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
Setup Format of short type
:
#<User Name>, <Password>, <Function Mode 19>, <0/1 (Buzzer On/OFF)> ,
<0/1 (Vibration On/OFF)>*
Example
:
#username,0000,19,0,0*
Setup Format of long type
:
#<User Name>, <Password>, <Function Mode 19>, <0/1 (Buzzer On/OFF)> , <0/1
(Vibration On/OFF)>, <1 (Interval of beep sound)> , <180 (Interval of vibration)>*
Example
:
#username,0000,19,1,1,1,180*
SMS Text
Description
#
Start sign.
username
Default ID of BRACELET.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
19
Function code for toggling the beep sound and vibration
0/1
Toggle the beep sound:
0: turn off the beep sound during the Alarm event.
1: turn on the beep sound during the Alarm event. (default)
0/1
Toggle the vibration:
0: turn off the vibration during the Alarm event.
1: turn on the vibration during the Alarm event. (default)
1
This parameter is for setting up the interval of beep sound. The value range is
from 0.2 to 65000. “1” means 1 second. (default)
E.g. Once the alarm event is triggered, the device will beep every 1 second until
the “alarm off” command has been received.
180
This parameter is for setting up the interval of vibration. The value range is from
1 to 65000. “1” means 1 second. (The default setting is 180)
E.g. Once the alarm event is triggered, the device will vibrate every 180 seconds
until the “alarm off” command has been received.
*