![Samyung SDF-310 Installation & Operation Manual Download Page 53](http://html1.mh-extra.com/html/samyung/sdf-310/sdf-310_installation-and-operation-manual_3802619053.webp)
53
3. Rear connector pinout
Pin position at the back of the transmission indicator.
ETHER NET
NAME1/ALARM
R
TRANSDUCER
POWER (DC12/24)
NAME2/SENSOR
②
COMMON_1
③
TD+
④
GND
⑤
EXT_ON/OFF
⑥
NC
⑦
NC
⑧
NC
⑨
RD-
①
GND
②
GND
③
NMEA_IN
④
NMEA_OUT
⑤
NC
⑥
ALARM
⑦
ALARM_GND
①
TEMP1
②
TD_L+
③
TD_H+
④
TD_GND
⑤
TD_L-
⑥
TD_H-
⑦
TEMP2
⑧
NC
①
PWR+
②
EARTH
③
PWR-
①
GND
②
GND
③
NMEA_IN
④
NMEA_OUT
⑤
SPEED SUPPLY
⑥
SPEED
⑦
TEMP
⑧
GND
⑩
COMMON_2
⑪
TD-
⑫
GND
⑬
NC
⑭
NC
⑮
NC