Samyung BNW - 50 User Manual Download Page 21

 

21 

4.4.2    SETUP ALARM DEVICES 

On this menu, you may turn ON/OFF the alarm of the 

each processor unit’s interface terminal ALARM A~G by 

using 

  and 

.  Right  bottom  picture  with 

checked  boxes  means  activating  the  2

nd

  stage  audible 

alarm,  and  the  rest  means  activating  3

rd

  stage  audible 

alarm. (Refer to 6.14 2

nd

 stage audible alarms) 

 

     

                   

 

 

eg)

 

Not using the additional visual alarm and 1

st

 stage audible alarm 

- Activate (ON) 2

nd

 stage audible alarm : Alarm A, B, C                   

- Activate (ON) 3

rd

 stage audible alarm : Alarm D, E, F, G 

 

Also, by  using the additional  reset unit, you can activate (ON) the  visual alarm(VIS) and the 1

st

 stage 

audible alarm(AUD) same as the standard reset terminal, through the Alarm A & B interface terminal. 

 

     

                   

 

 

eg)

 

Using the visual alarm and the 1

st

 stage audible alarm. 

- Activate (ON) the visual alarm : A                                 
- Activate (ON) the 1

st

 stage audible alarm : B 

- Activate (ON) the 2

nd

 stage audible alarm : C                   

- Activate (ON) the 3

rd

 stage audible alarm : D, E, F, G 

Summary of Contents for BNW - 50

Page 1: ...1 USER MANUAL USER MANUAL USER MANUAL USER MANUAL BNW 50 Bridge Navigational Watch Alarm System Rev M00 0481 00...

Page 2: ...2...

Page 3: ...duced under protected environment of electrostatic discharge This is because the most of the semiconductor equipment used in the PCB can be damaged easily by the electrostatic discharge You must preve...

Page 4: ...1 SEQUENCE OF ALARM 10 2 3 2 Visual Alarm 11 2 3 3 1 stage Audible Alarm 11 2 3 4 2 stage Audible Alarm 11 2 3 5 3 stage Audible Alarm 11 2 3 6 Emergency Call 11 CHAPTER 3 PRODUCT SPECIFICATION 12 3 1...

Page 5: ...Y 25 4 5 1 DORMANT PERIOD 25 4 5 2 Visual alarm 25 4 5 3 1st stage audible alarm 26 4 5 4 2nd stage audible alarm 26 4 5 5 3rd stage audible alarm 27 4 5 6 Emergency call 27 4 5 7 Failure indicator 28...

Page 6: ...SUAL ALARM VIS 34 6 13 1ST STAGE AUDIBLE ALARM AUD 34 6 14 2ND STAGE AUDIBLE ALARM ALARM A G 35 6 15 3RD STAGE AUDIBLE ALARM ALARM A G 36 CHAPTER 7 INSTALLATION CAUTION 37 7 1 GENERAL 37 7 2 LOCATION...

Page 7: ...FLUSH TYPE STANDARD 46 12 4 BNW 53 FLUSH TYPE STANDARD 46 12 5 MONTION SENSOR STANDARD 47 12 6 BNW 52 DESK TYPE OPTION 47 12 7 BNW 52 WATERTIGHT TYPE OPTION 48 12 8 BNW 53 DESK TYPE OPTION 48 12 9 CA...

Page 8: ...FLUSH TYPE OUTLINE DRAWING 57 13 9 BNW 52W WATERTIGHT TYPE OUTLINE DRAWING 58 13 10 BNW B FLUSH TYPE OUTLINE DRAWING BNW 52 53 59 13 11 MOTION SENSOR DND 300M OUTLINE DRAWING 60 CHAPTER 14 WARRANTY I...

Page 9: ...dard requirement Existing Vessel requires to install the equipment before the first inspection after the below date Existing passenger ship and Vessels under 3000t 1st JULY 2012 Existing vessels over...

Page 10: ...ircumstances 2 1 3 AUTO Mode On this mode BNWAS system operates automatically once vessel s heading or the track control system when signal has been inputted is operating refer to 6 5 input terminal f...

Page 11: ...captain s cabin 2nd stage audible alarm is triggered if timer is not RESET within the 15 seconds after 1st stage audible alarm is triggered 1st stage and 2nd stage audible alarms are both triggered a...

Page 12: ...A data Reset alarm etc Inputting DC12V power supply and reset of motion sensor and reset unit Outputting the alarm signal for reset and alarm unit Outputting the NMEA data for blackbox VDR Outputting...

Page 13: ...TION METHOD Quad element PIR and microwave pulse Doppler MW frequency 10 525GHz SIZE 115 x 61 x 37 5 mm H x W x D WEIGHT 120g BRACKET EXCLUDED OPERATION TEMPERATURE 15 C 55 C DETECTIVE ANGLE 120 150 D...

Page 14: ...able 4 2 Alarm unit installation accessory BNW 53 A 7 SET Flush type 5 Motion sensor installation accessory included DND 300M 2 SET Additional installation available 3 6 2 BNW 50 OPTION SPECIFICATION...

Page 15: ...Note EMG Pressing down this button for 2 seconds will activate the emergency call function By pressing down for another 2 seconds will deactivate the alarm EMERGENCY Call MENU Used to get into the men...

Page 16: ...to the selected function or change the setting Control key 4 2 SETTING PASSWORD Once power is connected to the equipment this screen will show Captain may set the password that he should only know If...

Page 17: ...herefore adjusting the setting can be only done by authorized person captain Checking the password In order to get to the menu password is required When MENU is pressed CHECK MASTER PASSWORD appears t...

Page 18: ...etting alarm mode OFF Mode BNW 50 does not operate under this mode On the operational status it shows MANUAL for MODE and OFF for ALARM STATE MANUAL Mode Under this mode BNW 50 always operates On the...

Page 19: ...or ALARM STATE Setting dormant period and the period between the second and third alarm You can control the Dormant period 3 12minutes and the period between the second and third alarm 90 180 seconds...

Page 20: ...andard reset terminal Move the cursor to the wanted menu then press then you may decide the use of additional reset unit Changing the period of the 1st stage audible alarm s warning alert You can chan...

Page 21: ...sual alarm and 1st stage audible alarm Activate ON 2nd stage audible alarm Alarm A B C Activate ON 3rd stage audible alarm Alarm D E F G Also by using the additional reset unit you can activate ON the...

Page 22: ...unit version and figures S00 017 2011 07 12 and D0 0 017 20 11 07 12 shown on the right side means the display unit s version of the each processor unit Initialize When you wish to initialize the set...

Page 23: ...check the visual alarm 1st stage audible alarm and other connected alarms immediately Move cursor to the test mode by using then press this will activate the alarm However when setting the additional...

Page 24: ...data on SD card After inserting the SD card by using and check the box and save by pressing MENU BNWAS_SAMYUNGENC_VDR txt file will be created in the SD card and at the same time VDR data will be save...

Page 25: ...he reset of the timer can be done in 3 different ways For the additional reset input using additional unit refer to 6 6 6 8 Manual way of pressing RES button from the display unit of BNW 50 Manual way...

Page 26: ...hin 15 seconds after the 1st stage audible alarm is triggered then the timer will restart from 3 minutes 4 5 4 2nd stage audible alarm 2nd stage audible alarm will activate if timer has not been reset...

Page 27: ...ter this the time restarts from 3 minutes 4 5 6 Emergency call By pressing the button EMG down for 2 seconds 2nd stage audible alarm will activate immediately If no actions are taken then 3rd stage au...

Page 28: ...ower 110 220V AC or back up power 24V DC is not connected Main Power Failure or Back Up Power Failure will appear on the top of the display in red black writings Pictures below show Main Power Failure...

Page 29: ...n Color POWER LED lights up when power is connected Red LED AUTO LED lights up when AUTO is selected from the Operational mode Green LED ERROR LED lights up when the main or the back up power is not s...

Page 30: ...Alert interface output 28 29 PIN for machinery breakdown Interface input 30 31 PIN for activing track controller NMEA data output 32 34 PIN for blackbox VDR NMEA data reset alarm etc input 35 36 PIN...

Page 31: ...the flush mounting for the display unit BNW 50 Connect the display unit BNW 50 with the processor unit BNW 51 with cable Z8 2M 05 provided 24V GND TXD SLD RXD IN OUT 1 2 5 4 3 DISPLAY BNW 50 BNW 51 P...

Page 32: ...you have enough space to install the display unit 6 3 RESET SET UP RES1 LOW ALARM VIS AUD Connect the reset unit BNW 52 to the interface socket RES1 of BNW 51 Reset unit is usually installed near the...

Page 33: ...activation input Under the AUTO mode two brackets INP INP should be in contact for BNWAS to activate 6 6 Additional reset terminal RES2 LOW You can connect additional external reset unit or the motion...

Page 34: ...emergency call s terminal gets disconnected it will stop operating the emergency call will stop operating It is possible to connect the alarm contact signal coming from the outside with this terminal...

Page 35: ...terminal ALARM C 2nd stage audible alarm officer s cabin 3 connection terminal ALARM D 2nd stage audible alarm officer s cabin 4 connection terminal ALARM E 3rd stage audible alarm crew s quarter s c...

Page 36: ...l connected alarms will activate Delay setup for 2nd stage alarm s timer In large vessels the delay between the 2nd and 3rd stage alarms may be set to a longer value when installing from 90 180 second...

Page 37: ...on the bridge giving proper look out and preferably adjacent to visual indications Means of activating the reset function shall be easily accessible from the conning position the workstation for navig...

Page 38: ...0 150 and is not harmful to human By using the bracket attached to the sensor you may install it easily on the wall or the ceiling Input voltage 12 VDC 3V Power consumption Operating 26mA Standby 17mA...

Page 39: ...s power cable 3 Do not install it at the back of the partition 4 Avoid installing near the heat 5 Install it on the stable and hard surface 6 Avoid installing from windy environment 7 Do not install...

Page 40: ...technician if required Infrared ray PIR detective range adjustment Use the volume marked with PIR to adjust the detective sensitivity from 15 to 100 according to the ambulation test it is set at the m...

Page 41: ...the 2nd stage audible alarm 6 Go to the bridge and reset all the alarms by pressing the reset button 7 Press the emergency call button for 2 seconds Check if the 3rd stage alarm is displayed after the...

Page 42: ...ground wire Clean Use clean tissue or the soft fiber to clean the salt precipitate or dirt Do not use the chemical liquids as it may erase the letters or peel the writings on the equipment off 10 2 Fa...

Page 43: ...only 1 reset unit in the terminal pin number 9 3 Set BNWAS as MANUAL mode 4 Check if the visual alarm activates after 3 minutes 5 Press the reset button to check if the alarm resets 6 Set BNWAS as OFF...

Page 44: ...exceeded dormant period time A A Alert response V No alert response c c BNWAS Mode Refer to IEC 62616 3 1 1 c1 c2 c3 c1 AUT or MAN or OFF c2 Dormant period time by minutes 03 12 c3 Alert stage 1 2 or...

Page 45: ...0050 00 3 2A 250V 30mmX6mm 5 FUSE CODE NO 527 2002 2Q 2 12 2 BNW 51 STANDARD BNW 51 Processor Unit desktop NO Item External Feature STANDARD Q ty CHK Remark BNW 51 1 Processor UNIT POWER AUTO ERROR AL...

Page 46: ...et BNW 52 CODE NO E02 1800 00 1 BNW 52 A Reset unit installation accessory Stain piece type1 3X12 STS 2 Screw CODE NO 904 0237 01 4 BNW 52 CABLE RUBBER 3 Rubber CODE NO E02 1841 00 1 12 4 BNW 53 Flush...

Page 47: ...Reset unit desktop NO Item External Feature STANDARD Q ty CHK Remark BNW 52 1 RESET UNIT SAMYUNG Resetunit Push button to reset Reset BNW 52 CODE NO E02 1800 00 1 BNW B Desk type bracket BNW B 2 Brack...

Page 48: ...pe bracket installation accessory M3X6 STS304 3 Bolt CODE NO 900 0134 02 4 TYPE 1 3X12 STS 4 Screw CODE NO 904 0037 11 4 BNW 52 CABLE RUBBER 5 Rubber CODE NO E02 1841 00 1 BNW 52W Watertight reset uni...

Page 49: ...le CODE NO 576 2002 1K C 3 LENGTH OPTION Alarm unit installation cable SMALL UL 2464 6C X 20 AWG 3 Screw CODE NO 567 2006 1K C 5 LENGTH OPTION Alarm unit installation cable LARGE CVV SB 1 25SQMM X 2C...

Page 50: ...t Push button to reset SAMYUNG 1 PORT 1 PORT 1 PORT 1 2 PORT 1 PORT 1 PORT DC 24V Option or Local Supply System Fail Contact N O VDR AC 220V IEC61162 Track System Alarm Reset etc Contact N O RADR ECDI...

Page 51: ...28 31 30 32 DISPLAY RESET UNIT C B A 1 2 3 4 5 6 7 4 6 5 7 3 8 DISPLAY UNIT BNW 50 ALARM UNIT OPTION 12V GND 1 2 ALARM REMOT C 1 RES 24V 24V GND 24V GND 16 14 15 17 18 BNW 52 RELAY BNW 53 2 1 ALARM G...

Page 52: ...53 SAMYUNG SAMYUNG Assistance to bridge Assistance to bridge Alarm unit BNWAS 53 Alarm unit BNW 53 C 6 C 3 or E ALARM RES RES1 LOW MOTION SENSOR PROCESS UNIT BNW 51 Push button to reset Reset BNW 52...

Page 53: ...unit BNW 53 Max 10 OFFICER CABINS SAMYUNG SAMYUNG C 3 TAPING Assistance to bridge Assistance to bridge BNW 53 Alarm unit BNW 53 Alarm unit DND 300M DND 300M MOTION SENSOR MOTION SENSOR C 3 C 3 TAPING...

Page 54: ...54 13 5 BNW 50 OUTLINE DRAWING 1 A B C 126 5 1 2 3 4 B N W 5 0 ESC MENU EMG RES D E 183 1 5 6 7 93 5 1 8 9 7 6 1 8 5 4 3 2 113 5 1...

Page 55: ...A UD LOW ALARM RES1 12 A UD 11 8 9 10 V IS R ES 1 2V G ND 14 1 3 2 4V G ND NMEA TXD 33 TXD 198 1 F C D E B ALARM ALARM ALARM ALARM ALARM 20 2 4V 19 18 16 17 G ND 2 4V 2 4V G ND 23 24 2 5 21 22 G ND G...

Page 56: ...56 13 7 BNW 52 FLUSH TYPE OUTLINE DRAWING BNW 52 1 2 A 3 4 5 6 B C Reset unit to reset Push button SAMYUNG Reset 7 8 9 E D 29 7 1 126 1 90 1...

Page 57: ...57 13 8 BNW 53 FLUSH TYPE OUTLINE DRAWING 1 2 A 3 4 5 6 B C SAMYUNG BNW 53 Alarm unit Assistance to bridge 126 1 7 8 9 90 1 E D 29 7 1...

Page 58: ...58 13 9 BNW 52W WATERTIGHT TYPE OUTLINE DRAWING to reset A B 1 2 SAMYUNG 3 4 Push button Reset Reset unit BNW 52 5 6 127 1 178 1 7 8 9 C D E 22 1 175 1 92 5 1...

Page 59: ...59 13 10 BNW B FLUSH TYPE OUTLINE DRAWING BNW 52 53 66 1 1 2 A 3 4 5 6 B C 4 M3TAP 4 3 5 35 54 1 7 8 9 76 6 1 90 1 E D 90 1 108 2 1 114 1 1 2 0 1 38 1 13 1...

Page 60: ...60 13 11 MOTION SENSOR DND 300M OUTLINE DRAWING 1 3 2 4 A B C D E 122 8 1 5 6 7 8 9 58 1 79 1...

Page 61: ...1 year warranty is given from the date of purchase BUT break down caused by the user s inappropriate use will be charged HEAD OFFICE A S ADDRESS 65 20 Namhang Dong 2 Ga Youngdo Gu Busan Korea COMPANY...

Page 62: ...62...

Page 63: ...63...

Page 64: ...g Youngdo Gu Busan Korea 606 083 Tel 051 601 5555 6666 Fax 051 413 4446 412 6616 A S 65 20 Namhang Dong 2 Ga Youngdo Gu Busan Korea Tel 051 601 5570 5574 Fax 051 416 5515 SEOUL OFFICE Tel 02 569 6242...

Reviews: