4.4 Change of a single die
Open the dies to the maximum retraction. Open the supply disconnecting device.
CAUTION! SUPPLY DISCONNECTING DEVICE
SHALL ALWAYS BE OPENED DURING THE
INSTALLATION OF THE DIES.
Prior to installing the dies, clean the contact surface of
both the die set and master dies properly to avoid
damaging the surfaces
Pull the pull pin in the master die with the tool delivered
together with the machine (see figure).
Insert the die with the retaining pin into the master die,
die number always towards you. Release the pull pin.
After installing all the dies, make sure they are straight
and properly seated in the master dies.
4.5 Crimping
WHEN CRIMPING A FITTING, HOLD THE HOSE FAR ENOUGH TO AVOID CRIMPING
The machine can be operated manually
by using the crimping- and the opening -
push buttons or with semi-automatism.
YOUR HAND! DO NOT CRIMP THE EDGE OF THE DIE!
1. Adjust the recommended crimping
diameter.
2. Press the crimping button until the
dies hold the fitting lightly.
3. Press the crimping button until the
dies stop.
4. Open the dies and remove the fitting.
5. Check the crimping diameter.