PAGE 5 of 84 HU-SOUTHWEST-1480 GAS-FIRED HUMIDAIRE UNIT
© SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED
problems are simple in nature (for instance a gas supply valve that is closed) and you may
be able to correct it without assistance.
Once flame is established, the system will begin warming up. There is a 90-second
(default) delay that prevents the water pump from coming on (even if the scanner reports
cotton in the lint flue riser) during this period.
TIPS
Many ginners normally turn the Humidaire Unit on first in the gin startup sequence to
give additional warm-up time for improved operation.
WHY IS THERE A DELAY AFTER I TURN IT ON?
After the burner start button is touched, the combustion control computer begins opening
and closing valves to test the integrity of various safety switches. If it finds a problem
with one of these devices, it alerts the operator with an ALARM or ERROR message that
corresponds to the problem.
Picture of flame
indicates flame
is established.
Picture of water
indicates pump
is running.
Actual water
temperature.
Actual air
temperature.
Water temperature
setting.
Water pump ON-
OFF buttons.
Air temperature
setting.
Burner ON-OFF
buttons.
Access the Humidaire
Speedometer.
Access technical and
diagnostic routines.
View operation details
and water statistics.
Home Screen