PAGE 48 of 84 HU-SOUTHWEST-1480 GAS-FIRED HUMIDAIRE UNIT
© SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED
Lint flow
to riser
To battery
condenser
“Used” air exhaust should
enter downstream of scanner
14900A Lint Flue Scanner
“eye” points upstream of
cotton flow as shown here.
See the installation, settings
and use section for the
scanner in this manual for
more information.
Recommended location for Lint
Flue Scanner in the riser is after an
elbow on the outer radius as
shown. This position gives the
“eye” maximum exposure to the
lint. The lint flowing by also wipes
the “eye” glass off. Locate the
scanner in an easy to get to
location
for
adjustment
and
maintenance.
Electrical Panel
CAT-5B Ethernet Cable to
optional Moisture Mirror II
connects to PLC Ethernet
port here.
See Drawing CA15002B for
network ID switch settings.
Lint Flue Scanner (or hopper
panel), fan interlock signal and
moist air thermocouple
connect to terminals located in
this area.
See Drawing CA15110A in
this manual for electrical
hookup information.