- 23 -
Heater
abnormal
HE
200
If the washing water temperature is increasing more than
4°C every 5sec during the operation of washing heater, this
error will occur. If higher than 100°C of the washing water is
detected for longer than 6sec at the temperature sensor, this
error will occur also.
(due to a fire caused by an operation of washing heater
without water)
Open the main
relay at once,
and Power will
be automatically
off after 5sec.
HE1
If the water temperature remains less than 50°C for longer
than 10min after the operation of washing heater, or if it
doesn't increase to 2°C higher than the initial temperature of
the heater for longer than 8sec, this error will occur. (caused
by breakdown of washing heater or opening of thermostat)
Power Off
HE2
If the fan housing temperature remains less than 35°C for
preheat dehydration/low temp drying or less than 50°C for
drying of the others, and if it doesn't rise to 5°C higher than
the initial temperature of the heater for longer than 8sec, this
error will occur.
(caused by breakdown of drying heater or opening of
thermostat)
Power Off
Cooling
abnormal
CE
If the water temperature doesn't fall to lower than 55°C for
longer than 30min after the start of washing water cooling,
this error will occur. If the fan housing temp sensor doesn't
fall to lower than 70°C for longer than 30min after the start of
cooling of the last internal temperature for drying.
Start button
Unbalance
error
UE
If time sum of retrial for sensing vibration during dehydration
becomes longer than about 10min, this error will occur at
third times after 2-times operation of cloth-untwisting during
water feeding and whirling.
Start button