WEA453e Installation Manual
Version 1.0
Samsung Electronics America
Page
57
of
117
It is a cascade type of connection in which three arrestors are connected to the
MGB using the ground cable.
Figure 36.
Connecting a Ground Cable to the Outdoor AP (3)
2) After assembling Arrestor-1 and Arrestor-2 using a pressure terminal and a heat shrink
tube, secure only Arrestor-1 using the fastening components.
Fastening components, such as the pressure terminal or cables, must meet the
UL or equivalent standards requirements.
Ex) Manufacturer: Panduit
Arrestor: 4 mm
2
Pressure Terminal (S10-10R-Q)
Ground Cable
MGB