ALIGNMENT AND ADJUSTMENTS
3
NO
Error Code
(Diagnostic Code
Error Image)
Description
Corrective Action
11
TE1
This occurs when the water
temperature sensor fault is detected
continuously for 5 seconds.
Go to “ Board Input Test” and check
Water Temperature. Check loose
or pinched wires. Replace PCB or
thermistor.
12
3E
MICOM is attempting to drive the motor
but is not getting any response signals
from the hall sensor. Visual check shows
motor is not running. (Locked, Defective
Hall Sensor or Overload)
Evaluate wire harness for loose or
unhooked connections. Go to “ Quick
Test Mode” and test Motor.
13
HE
Heater Relay Failure (No Heater Relay
Check Signal)
Replace PCB
14
nF1
The hot/cold water hose connection is
not correct.
Please connect the hot/cold water
hose connection correctly.
15
SUd
Suds is detected during the washing
session. (“SUdS” is not an error. When
it finishes washing, End and the SUd
code will blink in turn.)
Guide a user to reduce amount of
detergent usage.
16
AE
Communication error between SUB
PBA and MAIN PBA
Check Main PBA, SUB PBA & Wire-
harness. Replace PCB
17
PE
(Clutch Motor Error)
This error occurs when the position of
the clutch is not detected.
- If the position detection signal is not
received 15 seconds after the clutch
motor starts, the spin drum is shaken
left and right and then the motor is
restarted.
If the motor position signal is not
received even after 3 reattempts, a PE
error occurs.
1. Check the clutch motor.
2. Check the assembly status of the
clutch motor.
3. Check the wire connector terminals.
18
PE1
(clutch hall sensor
error)
After the completion of the clutch
position detection, and the clutch
hall signal is invalid, the spin drum
is shaken left and right and then the
clutch hall signal is evaluated again.
This, if the clutch hall signal is still
invalid, the clutch position switching
status is checked and then the
operation is restarted.
(If the 15 reattempts fail, this error
occurs.)
1. Check the clutch hall sensor.
2. Check the wire connector terminals.
3. Check the clutch switching status.
- Check the coupling assembly and
disassembly status.
19
8E
If the output from the MEMS sensor
is over 4.5V or under 0.5V and it
continues for 5 seconds, this error
occurs.
1. Check the MEMS sensor and PBA.
2. Check the wire connector terminals
To avoid risk of electrical shock, personal injury or death; disconnect power to washer