Operating Instructions and Installation
Samsung Electronics
No.
LED Display
Explanation
Yellow
Green
Red
1
○
○
○
Power off/ VDD NG
2
○
○
◎
IPM Over Current(O.C)
3
○
○
●
Abnormal Serial communication
○
●
●
4
○
◎
○
Compressor Starting error
5
○
◎
●
Normal Operation
6
○
●
○
Compressor Lock error
7
○
●
◎
DC-Link voltage under/over error
8
◎
○
◎
Outdoor temperature sensor error(Dual/Single)
9
◎
○
●
Discharge over temperature(Dual/Single)
10
◎
◎
○
Discharge temperature sensor error(Dual/Single)
11
◎
◎
●
Current sensor error
12
◎
●
○
Compressor Limit error
13
◎
●
◎
Coil temperature sensor error(Dual/Single)
14
◎
●
●
1min. Time out Communication
15
●
○
○
Fan error
16
●
○
◎
OTP error
17
●
○
●
Compressor rotation error
18
●
◎
○
Operation condition secession(Dual only)
19
●
◎
◎
DC-Link voltage sensor error
20
●
◎
●
I_Trip error / PFC Over current
21
●
●
○
GAS Leak error(Dual/Single)
22
●
●
◎
AC Line Zero Cross Signal out
23
●
●
●
Power ON reset(1sec)
24
◎
○
○
Capacity miss match
25
○
◎
◎
Test Operation at Cooling Mode
26
◎
◎
◎
Test Operation at Heating Mode
● :
LED ON,
○ :
LED OFF,
◎ :
LED BLINK
3-2 Outdoor LED Error Display and Check Method
3-4
25888A(1)_1.indd 11
2006-04-14 ソタネト 2:21:38
Summary of Contents for UH035EAV Series
Page 46: ...MEMO Samsung Electronics 4 27 ...
Page 57: ...Samsung Electronics 5 11 5 3 Ass y Control Out UH035EAV DB93 03453A ...
Page 59: ...Samsung Electronics Ass y Control Out cont UH052EAV DB93 03665D UH070EAV DB93 03665E 5 13 ...
Page 106: ...Samsung Electronics MEMO 8 5 ...
Page 111: ...9 2 Refrigerating Cycle Diagram 9 5 Samsung Electronics EH035EAV UH035EAV ...
Page 112: ...Samsung Electronics EH052EAV UH052EAV EH070EAV UH070EAV Circuit Descriptions 9 6 ...
Page 164: ...Samsung Electronics 14 10 MEMO ...
Page 165: ...Samsung Electronics MEMO 14 11 ...