12-2-15 DC Link Over voltage/ Low voltage error
1. Checklist :
1) Is the power voltage normal?
2) Is the voltage of front and back terminal of indoor(outdoor) power relay normal?
3) Is the resistance value for DC Link voltage detection NORMAL?
4) Is the resistance value of DC Link discharge normal?
5) Is the appearance of DC Link Capacitor normal?
2. Troubleshooting procedure
Yes
Terminate the service.
Exchange the PCB.
Exchange the PCB.
Exchange the PCB.
Yes
Yes
Yes
No
No
Yes
Terminate the service.
No
Yes
Yes
Yes
Restart after power off.
Is the DC Link voltage error occurred again?
Is the front and back terminal voltage of
indoor/outdoor power relay normal?
Is the resistance for the
detection of DC Link voltage normal?
Exchange the reactor.
Is the appearance of
DC Link Capacitor normal?
Is the power voltage normal?
Reassembly the PCB.
Is the resistance value of
DC Link discharge normal?
Is the reactor insulation damaged?
Exchange the PCB.
Exchange the PCB.
Troubleshooting
12-17
25888A(1)_1.indd 46
2006-04-14 ソタネト 2:26:15
Summary of Contents for UH035EAV Series
Page 46: ...MEMO Samsung Electronics 4 27 ...
Page 57: ...Samsung Electronics 5 11 5 3 Ass y Control Out UH035EAV DB93 03453A ...
Page 59: ...Samsung Electronics Ass y Control Out cont UH052EAV DB93 03665D UH070EAV DB93 03665E 5 13 ...
Page 106: ...Samsung Electronics MEMO 8 5 ...
Page 111: ...9 2 Refrigerating Cycle Diagram 9 5 Samsung Electronics EH035EAV UH035EAV ...
Page 112: ...Samsung Electronics EH052EAV UH052EAV EH070EAV UH070EAV Circuit Descriptions 9 6 ...
Page 164: ...Samsung Electronics 14 10 MEMO ...
Page 165: ...Samsung Electronics MEMO 14 11 ...