SPEED DOME CAMERA
User Guide
90
SPEED DOME CAMERA
User Guide
91
Product Specification
Model Name
SPU-3750T
SPU-3700
Imaging Device
1/4 inch, Double Density Interline Transfer CCD
1/4 inch, Super HAD color CCD
TV Standard
NTSC / PAL
Total Pixels
NTSC: 811(H) × 508(V) / PAL: 795(H) × 596(V)
Effective Pixels
NTSC: 768(H) × 494(V) / PAL: 752(H) × 582(V)
Scanning System
2:1 Interlace
Synchronization
Internal
Internal/External(AC Line Lock)
Horizontal Scan
15.734 KHz
Vertical Scan Rate
59.94 Hz
Horizontal
550 TV Line(Color)/680 TV Line(B/W)
Min. Illumination
0.7 Lux (50 IRE @ F1.6 Color)
0.03Lux (50 IRE @ F1.6 B/W)
0.4 Lux (50 IRE @ F1.6 Color)
0.02Lux (50 IRE @ F1.6 B/W)
S/N (Y Signal)
50 dB
Video Output
CVBS:1.0Vp-p/75Ω
Zoom Ratio
37X (Optical),12X (Digital)
Focal Length
3.5~129.5mm (F1.6 ~3.9)
Min. Object
1.9m
Angular Field of
view
H:55.5°(Wide)~1.59°(Tele)
V:42.5°(Wide)~1.19°(Tele)
Focus
AUTO / MANUAL / ONE-SHOT
Zoom Speed
2.5sec
IRIS
AUTO/MANUAL
Lens Initialization
Built-In
Auto Tracking
Built-In
-
Horizontal
Rotation Angle
360° Endless
Horizontal
Rotation Speed
Manual:0.024°/sec ~120°/sec, Preset 500°/sec
Vertical Rotation
Angle
-5° ~ 185°
Vertical Rotation
Speed
Manual:0.024°/sec ~120°/sec, Preset 500°/sec
Troubleshooting
I can use the controller, but I
can’t activate the Sequence
command.
▶
When the camera's internal temperature is
between -10
℃
to -20
℃
, the motor may
malfunction, limiting the use of the Sequence and
Turbo commands.
-
▶
Once the internal temperature reaches -10
℃
or
higher, all Sequence modes become reactivated
normally.
-
I can't get rid of this
message
from the screen: “ Fan life
Expired. Replace the Fans.”
▶
Please make sure to "Clear" the message from
the screen.
80
The camera suddenly resets
itself while displaying the
black screen.
▶
Such symptoms may occur if the camera's
temperature increases from -20
℃
or lower to
-20
℃
or higher.
-
▶
The motor may malfunction at temperatures lower
than -20
℃
; please reset the camera and
reactivate the [Initialize] mode.
-
“Please Check Heater
System” appears.
▶
The heater may malfunction. Turn off the camera
and call where you bought.
-
"Auto Refresh(Wait)"
appears and the camera
reboots.
▶
Such symptoms may occur if the camera's
temperature increases from -10
℃
or lower to
-10
℃
or higher to prevent the malfunction of
motor.
-
Check the Power cord's by periods
•ThePowercord'scoating
has been damaged.
•Thepowercordishotto
touch when the product is
in operation.
•Thepowercordgetshot
after being folded or
pulled on.
Continuing to use the product when its power cord is
damaged constitutes an electrical and fire hazard.
The power plug must be removed from the outlet
immediately, and a qualified service personnel or
your system provider should be contacted for
assistance.
-