background image

English

 

_6

When done, adjust the optical axis and insert the cover.

To attach to the pole

Pull out the cables from the wiring hole of the pole; insert the 
U-shaped pole bracket to the pole

Attach the sensor to the bracket and arrange the cables as 
necessary.

same as in wall-mounting

Put the cover as original.

Pole external diameter: Φ38~Φ46

Channel Setting (SIA-0120D)

To prevent misalarming due to possible frequency interference between two or more sensors in one place, set the channel 
respectively.

4.

1.

2.

3.

Cable-In Hole

Pole Bracket 
(optional)

<1 CH>

<2 CH>

<3 CH>

<4 CH>

Summary of Contents for SIA-0120

Page 1: ...t fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the appar...

Page 2: ...head symbol within an equilateral triangle is intended to alert the user to the presence of dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the liter...

Page 3: ...rect sunlight near heating equipment or heavy cold area Do not place this apparatus near Do not attempt to service this apparatus yourself Do not place a glass of water on the product Do not install near any magnetic sources Do not block any ventilation openings Do not place heavy items on the product User s Manual is a guidance book how to use the products The meaning of the using sign in the boo...

Page 4: ... Bracket What s Included Steel Bracket x2 Screw x4 Film User Manual Warranty Card U shaped Bracket x2 optional Power LED Alarm LED Temper Monitor Jack Channel Switch Terminal Good LED Response Time Control Wheel Sight Window Lens Vertical Angle Adjustable Screw ...

Page 5: ...ce or unsecured pole is not allowed Do not install it in a place where the infrared light is blocked due to a seasonal reason such as thick wood or bushes Keep it away from the muddy water or sea water keeping splashing the infrared light is likely to be blocked by the muddy water or sea water Installation To mount on the wall Loosen the screw to remove the cover of the sensor as shown Attach the ...

Page 6: ...he pole Attach the sensor to the bracket and arrange the cables as necessary same as in wall mounting Put the cover as original Pole external diameter Φ38 Φ46 Channel Setting SIA 0120D To prevent misalarming due to possible frequency interference between two or more sensors in one place set the channel respectively 4 1 2 3 Cable In Hole Pole Bracket optional 1 CH 2 CH 3 CH 4 CH ...

Page 7: ...ding to the scanning range For extension of the radiation IR beam according to the scanning range of the transmitter or receiver please refer to the following table L A 120m 3 6m Adjusting the optical axis Connect both transmitter and receiver and turn them on Look through the mirror of the sight and adjust the sensor so that the other sensor can be positioned in the center of the mirror You can u...

Page 8: ... Good 2 9V or lower 2 1V or lower To be adjusted Using the attenuation film for optimal adjustment of the optical axis Attach the attenuation film to the reflection part of the receiver in order for fine tuning after the initial optical axis adjustment Make adjustment until the Good LED turns green Remove the attenuation film and close the cover The attenuation film is a special film designed especially ...

Page 9: ... transmitter and receiver The cover of the transmitter or receiver has impurities on it 1 2 3 Adjust the optical axis as necessary Remove the obstacle Wipe out the impurities with a soft cloth 1 2 3 The alarm sounds intermittently Disconnected cables Fluctuation of the power voltage There exists an obstacle between transmitter and receiver There exists a different strong power source around the tr...

Page 10: ...or higher Alarm 1 0V or lower Ready 2 0 2 2V Good 2 2V or higher Current Consumption Receiver 19mA Transmitter 23mA Receiver 31mA Transmitter 26mA Alarm Out Dry contact relay output 1C COM N C N O Reset Interruption time off relay approx 1 sec Temperature 25 C 60 C Temper Output Dry contact Micro SW COM N C Adjustment of Optical Axis Horizontal 180 90 Vertical 20 10 Installation Outdoor Indoor Opt...

Page 11: ...ble harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environme...