SGH-X600 Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
7-
16
11. Camera part
"Camera" function does not work
Yes
No
Connect the camera module
Check the Camera
connector
Yes
C503(VC2.8) = 2.8V?
No
Check R506
Yes
OSC500 Pin 3 = 24MHz?
No
Check OSC500 and R502
Yes
C435(U500 RESET) =
2.8V?
Yes
No
Check the PMU related SPVDD
Is there another problem?
END
Replace the camera
module
Yes