2-6
2-5
DIGITAL VIDEO RECORDER
Connection with RS-485
If you control cameras, remote control is allowed through connection with RS-485 (up to
1.2km).
A. Communication method
●
Data transmission method: Start-Stop Asynchronized Serial Interface
●
Protocol: 8 bit Data, 1 Stop bit, None Parity
●
Transmission speed: 4800, 9600, 19200, 38400, 115200 bps
B. RS-485 terminal and Pin specifications
C. Data Format (Samsung Protocol)
DATA +
DATA -
9 Byte Fixed
( ) : Byte numbers
Start Code (A0H)
(1)
Data Byte
Type
Contents
Remarks
Byte 1
Start Code
0xA0
Start of Data Packet
Byte 2
Sender Addr.
Transmission Address
Source Range (0x00 ~ 0xFF)
Byte 3
Target Addr.
Reception Address
Destination Range (0x00 ~ 0xFF)
Byte 4
Only Image Recorder Command
0x0A
Byte 5
Key Function
Range (0x01 ~ 0xFF)
Byte 6
Command
0xFF
0xFF
Byte 7
0xFF
0xFF
Byte 8
0xFF
0xFF
Byte 9
Check Sum Lower byte of (0xFFFF - (values adding Byte 2 ~ Byte 8))
Start Addr.
(1)
Target Addr.
(1)
Command
(5)
Check Sum
(1)
D. Code value by key
Function
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6, 7, 8
Byte 9
Response
(Byte 5)
RECORD
0xA0
Src.Addr
Dest.Addr.
0x1A
0x0B
0xFF
Check Sum
Byte 5
REC LOCK
0xA0
Src.Addr
Dest.Addr.
0x1A
0x0A
0xFF
Check Sum
Byte 5
VCR
0xA0
Src.Addr
Dest.Addr.
0x1A
0x3D
0xFF
Check Sum
Byte 5
SEARCH
0xA0
Src.Addr
Dest.Addr.
0x1A
0x02
0xFF
Check Sum
Byte 5
MENU
0xA0
Src.Addr
Dest.Addr.
0x1A
0x01
0xFF
Check Sum
Byte 5
ENTER
0xA0
Src.Addr
Dest.Addr.
0x1A
0x35
0xFF
Check Sum
Byte 5
LEFT
0xA0
Src.Addr
Dest.Addr.
0x1A
0x06
0xFF
Check Sum
Byte 5
RIGHT
0xA0
Src.Addr
Dest.Addr.
0x1A
0x07
0xFF
Check Sum
Byte 5
STOP
0xA0
Src.Addr
Dest.Addr.
0x1A
0x08
0xFF
Check Sum
Byte 5
RIGHT
0xA0
Src.Addr
Dest.Addr.
0x1A
0x09
0xFF
Check Sum
Byte 5
UP
0xA0
Src.Addr
Dest.Addr.
0x1A
0x04
0xFF
Check Sum
Byte 5
DOWN
0xA0
Src.Addr
Dest.Addr.
0x1A
0x05
0xFF
Check Sum
Byte 5
EJECT
0xA0
Src.Addr
Dest.Addr.
0x1A
0x3E
0xFF
Check Sum
Byte 5
E. Others
●
Above data format and transmission speed may be changed depending on future
development conditions.
●
PC operates as Master, and Target Set as Slave in transmission/reception of data.
●
No status other than Set Key Function should be received.
(Some delay can be happen due to communication speed).