_
setup
setup
ALARM PRIORITY : Sets the priorities of
alarms. Setting the priorities of 8 alarms
defines the alarm notification priorities
of them in the highest orders.
By default, the priorities are set as
Alarm 1
Alarm 2
.....
Alarm 8.
When multiple alarms are generated
at the same time, alarm notifies in the
order of the default priority setting.
While an alarm is generating, no motion
is detected.
ALARM IN SET : Select the alarm
sensor operation between <
NO
>, <
NC
>
and <
OFF
>.
ALARM OUT SET : Set the alarm out
port matched to the alarm input port.
AUTO SET : Sets the pattern and scan
action for the corresponding alarm
input. When the alarm is generated, the
camera moves to the preset position
coupled to the corresponding alarm.
Presets 1 ~ 8 are coupled with alarms
1 ~ 8 inputs respectively, and the preset
9 is coupled to the motion detection.
The camera stops and remains in the corresponding preset position for the
defined <
DWELL TImE
>, and performs pattern or scan action defined by
the <
AUTO SET
>. Setting to <
OFF
> will discard with the pattern or scan
action after moving to the preset position.
- PATTERN 1 ~ 3 : Defined pattern action
- HALF1 : Patterns 1 and 2 in serial action
- HALF2 : Patterns 2 and 3 in serial action
- WHOLE : Patterns 1, 2 and 3 in serial action
- SCAN 1 ~ 4 : Predefined SCAN action
The <
ALARM1
> is used as external switching signal if the <
DAY/NIGHT
> is set to
<
EXT
>.
AUX OUT CONTROL : Sets whether to
sustain the alarm output despite of the
alarm generation or to output alarm out
signal while the coupled alarm is alive.
When selected <
OFF
>, outputs alarm
only if the alarm is generated. When
selected <
ON
>, it always outputs
alarm out signal despite of the alarm
generation.
M
ALARM PRIORITY SET
ALARM1
1
ALARM2
2
ALARM3
3
ALARM4
4
ALARM5
5
ALARM6
6
ALARM7
7
ALARM8
8
AUX OUT CONTROL
OUT1
OFF
OUT2
OFF
OUT3
OFF
AUTO SET
ALARM1
OFF
ALARM2
OFF
ALARM3
OFF
ALARM4
OFF
ALARM5
OFF
ALARM6
OFF
ALARM7
OFF
ALARM8
OFF
MOTION
OFF