84
This document cannot be used without Samsung's authorization
PRECAUTIONS(SAFETY WARNINGS)
Compare the room temp.
with sensed temp. using
Temp-Resistance Table.
When there is sensor error, display panel show that. When it occurs during the initial power on time, display
panel keeps blinking relevant 7-SEG and the refrigerator go into the emergency operation mode.
Under the emergency operation mode, the refrigerator can not do its normal operation. So check out with the
Self Diagnosis in this manual.
Start
Repair the defective contact
of the connector or insert
the connector properly
NO
YES
1) When the Ambient Sensor is defective,
MAIN PBA
connector (CN30) is inserted
properly.
Replace Thermistor.
NO
YES
Ambient Tem p Sensor
is ok.
Ambient-Sensor : Read the
resistance between CN30 #1
and #2
PBA & Thermistor are ok.
Check the contact of the
connector again.
Refer to Circuit Diagram and
Temp Sensor
Troubleshooting in this
manual.
Refer to Circuit Diagram and
Temp Sensor
Troubleshooting in this
manual.
Start
Replace Thermistor.
NO
YES
YES
YES
YES
2) When the Fridge Temp Sensor is defective (also applied to other sensors)
Fridge Sensor is good.
Repair the defective contact
of the connector or insert
the connector properly
NO
MAIN PBA Connector
(CN30) is properly
inserted
Check the circuit diagram and
correct any wrong inserted
connectors.
The order of
Connector(CN30) is the same
as the one in the circuit
diagram
Check MAIN PBA Cold Solder or
Short.
NO
NO
The voltage
between CN30 #7 and #5 is within
the normal range
PBA & Thermistor are good.
Check the contact of the connector again.
CN30
CN30
4-5-3. Self-Diagnosis Error (Defective Sensor)