71
This document cannot be used without Samsung's authorization
PRECAUTIONS(SAFETY WARNINGS)
※
Load mode Check list
NO
Part
Display (LED)
Operation contents
1
R-FAN HIGHEST
R-1-
ⓐ
,
ⓑ
When R-FAN HIGHEST operates, applicable LED blinks.
2
R-FAN HIGH
R-1-
ⓐ
When R-FAN HIGH operates, applicable LED blinks.
3
R-FAN LOW
R-1-
ⓑ
When R-FAN LOW operates, applicable LED blinks.
4
R-DEF HEATER
R-1-
ⓒ
When R-DEF Heater operates, applicable LED blinks.
5
Overload condition
R-1-
ⓔ
When ambient temperature is more than 93°F(34°C),LED blinks.
6
Low Temperature
condition
R-1-
ⓕ
When ambient temperature is less than 70°F(21°C),LED blinks.
7
Normal condition
R-1-
ⓔ
,
ⓕ
(Not blinks ALL LED) When ambient temperature is between 72°F(22°C) and 91°F(33°C).
8
Exhibition mode
R-1-
ⓖ
LED Blinks at the display mode.
9
ICE MAKER FULL
(DISPENSER model)
R-10-
ⓓ
When the Ice Maker's Bucket is full, applicable LED blinks.
10
COMP
F-1-
ⓐ
When COMP operates, applicable LED blinks.
11
F-FAN HIGHEST
F-1-
ⓑ
,
ⓒ
When F-FAN HIGHEST operates, applicable LED blinks.
12
F-FAN HIGH
F-1-
ⓑ
When F-FAN HIGH operates, applicable LED blinks.
13
F-FAN-LOW
F-1-
ⓒ
When F-FAN LOW operates, applicable LED blinks.
14
F-DEF HEATER
F-1-
ⓓ
When F-DEF HEATER operates, applicable LED blinks.
15
C-FAN HIGHEST
F-1-
ⓔ
,
ⓕ
When C-FAN HIGHEST operates, applicable LED blinks.
16
C-FAN HIGH
F-1-
ⓔ
When C-FAN HIGH operates, applicable LED blinks.
17
C-FAN LOW
F-1-
ⓕ
When C-FAN LOW operates, applicable LED blinks.
18
F-VALVE
F-10-
ⓑ
When F-VALVE opens, applicable LED blinks.
19
R-VALVE
F-10-
ⓒ
When R-VALVE opens, applicable LED blinks.
20
DISPENTER HEATER
F-10-
ⓔ
When DISPENSER HEATER operates, applicable LED blinks.
21
DAMPER
F-10-
ⓕ
When DAMPER opens, applicable LED blinks.
22
WIFI Status
WIFI Icon
When AP and Internet Disconnect : LED OFF.
When AP connect and Internet Disconnect : LED Blinks.
When AP and Internte connect : LED ON.