- 64/65 -
Step 1
Touch Display ”Energy Saver”+“Alarm” Key for
8sec at the same time until “Ding Dong” sound
occur.
※ When the Error occur
Measure to TIP
5-1.
- No
ERROR, “24 E”(F DEFROST ERROR)
Check Step2
Step 2
(Bimetal / HEATER OPEN)
① Inspect BIMETAL (RED+BLK) Open
replace part
- Normal: 0Ω,
Failure: OPEN
② Measure Heater (BRN+BRN) resistance
Replace Heater
- Normal : 50~72Ω,
- failure : Open & 0 Ω
③ Forced Heater On HEATER part
voltage
check WIRE
- Normal:105~125V,
Failure: 0V
④ Inspect Main PBA CN70 No.9(BRN),CN72
No.3GRY)+LINER part CONNECTOR WIRE
OPEN
Tip 9-4. Inspect F EVAP DEFROST BUILD
※ Operate self-diagnosis test on “TIP 5-1” first without power off.
Must check forced defrost operation after defrost repairing.
All EVAP freezing
CN 70 CN 72
Inspect BIMETAL
resistance
Inspect HEATER resistance
Next Page
Summary of Contents for RF263
Page 1: ...1 65 HA Repair Guide Refrigerator AW1 12 RF263...