- 62/65 -
Step 1
Touch the Display ”Energy Saver”+“Alarm” Key for
8 sec at the same time until “DingDong” sound
occur
※ When Error
Measure it to move TIP 5-1.
-No
ERROR, or “25 E”(R DEFROST ERROR)
Check Step2
Step 2
(Bimetal / HEATER OPEN)
① Inspect BIMETAL (RED+BLK) Open
Change the parts
- Normal: 0Ω,
Failure: OPEN
② Measure Heater (BRN+BRN)resistance
Replace Heater
- Normal : 90~115Ω,
- failure : Open & 0 Ω
③ Forced Heater On HEATER part voltage
Inspect WIRE
- Normal:105~125V,
Failure: 0V
④ Inspect Main PBA CN70 No.7(WHT),CN72
No.3GRY)+LINER part CONNECTOR WIRE
OPEN
Tip 9-3. Inspect R EVAP DEFROST BUILD
※ Before power off, operate self-diagnosis test on “TIP 5-1” first.
Must check forced defrost operation after defrost repairing.
Freezing occurs on all EVAP
CN 70 CN 72
Inspect Bimetal
Resistance
Inspect
HEATER
resistance
Summary of Contents for RF263
Page 1: ...1 65 HA Repair Guide Refrigerator AW1 12 RF263...