- 39/65 -
Tip 2-5. Inspect cooling power
(
※
Must select “Power
Freeze” first)
※ Do not turn off the power
Measure Self-diagnostic test
at “TIP 2-4”
Step 1
Touch Display “Energy Saver”+ “Alarm” Key at the
same time for 8 sec.
- Touch it until “chime” sound occurs after all
LEDs blink
※ If Error code appears
Move TIP 2-4
- If there is no error code
inspect Step 2
Step 2
(Inspect Comp operation)
① Touch the Display “Freezer” for 3 sec to enter
“Power Freeze”.
※ If compressor is not running due to
satisfied settings or defrost cycle, it will
take up to 8 minutes for compressor to
operate again.
② Check compressor operation.
- If the Comp does not operate
Check
Step 3
- If the Comp operate well
Check Step 6
Step 3
(Inspect Comp Wire)
① Check the problem on backside Unit left side
Comp Wire Connector assembly
② Inspect OLP & INVER WIRE after disassemble
Comp left side Relay Cover
③ When all things are correct, inspect
TIP 2-4
COMP ERROR and click moving
Connector
separation
Relay
separation
Next Page