- 63/65 -
Step 3
(DEFROST SENSOR)
① No freezing on the bottom of EVAP +
DEFROST SENSOR is being ice.
② Inspect and replace DEFROST SENSOR
open.
Step 4
(DEFROST SENSOR sensing location
problem)
① No freezing on the bottom of EVAP, EVAP top
+DEFROST SENSOR part don’t have freezing
② Move the location of DEFROST SENSOR to
freezing part.
Step 6
(HEATER location problem)
① When freeze only EVAP BOTTOM
- Improve DRAIN freezing.
② Check the drain hole blocking
with remove
freezing using STEAMER.
(Remove DRAIN freezing and foreign
substance)
③ DRAIN FIXER should be on CENTER.
④ Bending the HEATER into Bottom using
hand.
- DRAIN HOLE should be closed
.
★ HEATER can not contact to PLATE.
Step 7
(Total inspection after defrost repairing)
① Check the HEATER operation with forced
defrost operation after complete repairing
.
Touch “Energy Saver+Fridge” for 8sec at the
same time to off ALL LEDs and touch the
“Fridge”
key for 4 times to operate “rd”
.
Check HEATER(Brown-wire)AC voltage
supplying after “beep” sound appear.
② Off same way if there is no problem.
No EVAP top freezing
+ Sensor freezing
SENSOR
보임
MOVE
EVAP Top+ Sensor freezing
Summary of Contents for RF263
Page 1: ...1 65 HA Repair Guide Refrigerator AW1 12 RF263...