15
Product Specifications
Items
Specification
Model
RF28HM*
RF25HM*
Components for Freezer
Compressor
Model
MKV190C-L2B
Starting type
BLDC
Oil Charge
FREOL α - 15c
Evaporator
Freezer
SPLIT FIN TYPE
Refrigerator
SPLIT FIN TYPE
Condenser
Forced and Natural Convection Type
Dryer
Molecular shieve XH-9
Capillary tube(Dia x Length)
R : 0.032” x 118” (0.82mm x 3500mm) / F : 0.032” x
118” (0.82mm x 3500mm)
Refrigerant
R-134a
Room Temperature Sensor Components
Freezer
Model
Temperature
Selection
ON(℉)
OFF(℉)
THERMISTOR
(F-SENSOR) 502AT
-8℉(-22℃)
-5℉(-20℃)
-11℉(-24℃)
-2℉(-19℃)
1℉(-17℃)
-5℉(-21℃)
8℉(-14℃)
11℉(-12℃)
5℉(-15℃)
Flex
Model
Temperature
Selection
ON(℉)
OFF(℉)
THERMISTOR
(F-SENSOR) 502AT
29℉(-1℃)
32℉(0℃)
26℉(-3℃)
42℉(5℃)
45℉(7℃)
39℉(4℃)
Refrigerator
Model
Temperature
Selection
ON(℉)
OFF(℉)
THERMISTOR
(R-SENSOR) 502AT
34℉(1℃)
36℉(2℃)
32℉(0℃)
38℉(3℃)
40℉(4℃)
36℉(2℃)
46℉(7℃)
48℉(8℃)
44℉(6℃)
Defrost Related Components
Defrost Cycle
First Defrost Cycle (Concurrent defrost of F
and R)
6hr ±10min
Defrost Cycle(FRE)
12~23hr(vary according to the conditions used)
Defrost Cycle(REF)
6~11hr(vary according to the conditions used)
Pause time
12 ±1min
Defrost Sensor
F/R Defrost-
Sensor
Model
THERMISTOR (502AT)
SPEC
5.0 ㏀ at 77℉(25℃)
F/R Bimetal-thermo
Protector
Rated
AC 125V, 6A
Operating
temperature
Off : 140℉(60℃) / On : 104℉(40℃)