80
TROUBLESHOOTING
5) If F Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 inserted correctly?
IS
F Sensor unit normal?
Is the voltage between
MAIN PCB Connector CN30-”4”(Yellow) and
J23 JUMMPER normal?
Is the input voltage of
IC01 MICOM #82 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
F : CN30-"1"
↔
"4" measuring resistance value
** 0
Ω
: Short trouble /
Ω∞
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #82,
CN30-”4”(Yellow) and J23 JUMMPER from
PCB typical Ground part are similar.
→
Check the measure on the voltage of Resistance,
R309 due to the SMD MICOM
☞
Checking method of F Sensor resistance
CN30-"1"(Yellow)
↔
"4" (Yellow)
- Compare the temperature table after measurement.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F
Connector CN30-”4”(Yellow) to
J23 JUMMPER PCB typical Ground
☞
Checking method of F Sensor voltage
- Measure the voltage of Resistanec, R309(IC01 MICOM #82) on PCB or
CN30-"4"(Yellow)
↔
J23 JUMMPER
- Compare the temperature table after measurement.
Measuring voltage of CN30-"4"(Yellow)
↔
J23 JUMMPER are as below.
PCB Typical Ground
J23 JUMMPER
Start
YES
YES
YES
1
2
4
100mm
3
Cut as close as
Strip
: 10mm
possible to the
sensor
Strip : 10mm
Cover Sensor
[Strip the end of Main wire]
[Cut the Service Sensor
wire and strip]
5
6
7
8
[Assemble Cover Sensor
& Sensor]
[Connect Sensor and Main wire]
by twisng conductors
[Fix with insulaon tape]
[Assemble the Cover Sensor]
[Disassemble the Cover Sensor]
[Cut the Sensor wire]