12
Product Specifications
2-2) Specifications
ELECTRICAL SPECIFICATIONS
Defrost Control
From 12 to 22 hrs(comp.run time)
Thermo Bimetal Protector
140°F(60°C)(off) 104°F(40°C)(on)
Defrost Thermistor(502AT)
F: 50°F(10°C)(off)
R: 59°F(15°C )(off)
Electrical RatingAC115V 60Hz
11.6 Amps
Maximum Current Leakage
0.25 mA
Maximum Ground Path
Resistance
0.1 Ohm
Energy Consumption
562kWh/year
NO LOAD PERFORMANCE
Ambient Temperature
70°F(21°C)
90°F(32°C)
Refrigerator
34°F(1°C)~46°F(7°C)
34°F(1°C)~46°F(7°C)
Flex Zone
29°F(-1°C)~42°F(5°C) 29°F(-1°C)~42°F(5°C)
Freezer
-8°F(-22°C)~8°F(-14°C) -8°F(-22°C)~8°F(-14°C)
Run Time,%
< 60
< 80
REFRIGERATION SYSTEM
Refrigerant Charge (R134a)
5.64 oz(160g)
MKV190C-L2B
1314 Btu/hr(0.385kw)
Compressor oil
Freol α 15c
R Capillary tube(Dia, Length)
0.032",118"(0.82mm,3500mm)
F Capillary tube(Dia, Length)
0.032",118"(0.82mm,3500mm)
Compressor
Step Valve
C-Fan
Dryer
Condenser
Water Valve
INSTALLATION
Clearance must be provided for air circulation
AT TOP
2" (50mm)
AT SIDES
3¾"(95mm)
AT REAR
2" (50mm)
REFRIGERATOR
FLEX ZONE
FREEZER