83
CHECK THE INSTALLATION STATUS
This document cannot be used without Samsung's authorization.
Setting value
Temp.
compensation
FZ Compartment
code
0
0.0℃
1
-0.5℃
2
-1.0℃
3
-1.5℃
4
+0.5℃
5
+1.0℃
6
+1.5℃
7
+2.0℃
5) Operation rate changing table of dispenser heater
6) Temperature changing table of freezer compartment (When the Freezer works as a Fridge Mode)
ex) If you want to change the
dispenser heater operation
rate to +20%.
Set item
Dispenser Heater Rate
Reference
Value
Fridge Room 7-SEG
19
Set item
Freezer Temp Shift
Reference
Value
Fridge Room 7-SEG
31
Setting value
Rate change
FZ compartment
Code
0
+0.0%
1
[Sub-Heater] + 20% operation( up to 100% )
[C-Fan] C-Fan turn on after 10 minutes delay when Comp On
(It operates only external temperature 12℃ ~39 ℃ )