73
CHECK THE INSTALLATION STATUS
This document cannot be used without Samsung's authorization.
5-1-3. Display function of Load condition
1) If the '<' and '>' button are pressed simultaneously for 6 seconds during normal operation, the temperature setting display of Fridge
and freezer compartments will blink ALL ON/OFF with 0.5 for 4 seconds. In that case, you may take your fingers off both buttons and
press the '>' button to enter the Engineer Mode.
2) After entering Engineer Mode, press the '<' or '>' key to make the number '7' blinks. Then, press the 'O' button to enter the Load
Condition Display Mode. At LED all on state, only load condition display will blink ON/OFF with 0.5 seconds interval.
3) Load condition display mode shows the load that micom signal is outputting.
However, It means that micom signal is outputting, it does not mean whether load is operating or not. That is to say that though load
operation is displayed, load could not be operated by actual load error or PCB relay error etc.
(This function would be applied at A/S.)
4) Load condition display function will maintain for 30 seconds and then normal condition will be returned automatically.
5) Load condition display is as below. Only the load control LED will blink with 0.5interval in "Display LED".
①
'<'+ '>' Key are pressed simultaneously for 6 seconds. And the Control Display will blink with 0.5 second interval for 4
seconds.
②
In that case, you may take your fingers off both buttons and press the '>' button to enter the Engineer Mode.
③
After entering Engineer Mode, press the '<' or '>' key to make the number '7' blinks.
④
Then, press the 'O' button to enter the Load Condition Display Mode.
Enter the
Engineer Mode
②
③
①