34
CUSTOMER SET RELOCATION
[MMC 315]
This program is used to exchange information associated with two stations or add-on modules
(AOMs). All individual station assignments such as trunk ring, station group, station COS, station
speed dial and key assignments are swapped. A user can then relocate to a new station and oper-
ate it exactly like their original station.
Both stations being exchanged must be idle while program-
ming is done from a different keyset
.
There are two important rules to follow:
•
You can only exchange an OfficeServ 5000 series keyset with an OfficeServ 5000 series key-
set, a Euro keyset with a Euro keyset, and so on.
•
Generally, you can only exchange keysets or AOMs of the same type (e.g. Euro 6B with Euro
6B, 48B AOM with 48B AOM)
However, there are exceptions to the last rule:
•
You can exchange a Euro 12B for a Euro 24B keyset, and vice versa.
1
•
You can exchange an
i
DCS 18D for an
i
DCS 28D keyset, and vice versa.
2
•
You can exchange a DCS 48B AOM for an
i
DCS 64B or DS-5064B AOM, and vice versa.
3
Refer to the table, below, to determine which devices can be exchanged. Attempting to exchange
incompatible devices will result in an error message display (“INVALID DATA”).
1
If you are exchanging a Euro 12B and 24B keyset
, be aware that the 12B keyset will assume
the key assignments for the first 12 keys on the 24B keyset. Conversely, the first 12 keys on the
24B keyset will assume the key assignments for the 12B keyset.
2
If you are exchanging an
i
DCS 28D and 18D keyset,
remember that
for
18D keysets the first 10
programmable keys are numbered 01–10 and the last eight keys are numbered 21–28 (
not
11–18).
When you exchange 18D and 28D keysets you copy keys 01–10 to keys 01–10 and keys 21–28 to
keys 21–28. Keys 11-20 on 28D keysets will not be copied.
3
If you are exchanging a 48B AOM and a 64B AOM
,
the 48D keyset will assume the key as-
signments for the first 48 keys on the 64B AOM. Conversely, the first 48 keys on the 64B AOM will
assume the key assignments for the 48B AOM.
You must first remove any association with
master stations, using MMC 209, otherwise an error message will be displayed (“ER-
ROR:AOM MASTER”)
.