4. Troubleshooting
6) Image registration problem occurs after ACR (Auto Color Registration)
•
Symptom
:
Image registration problem occurs after ACR.
•
Cause
:
LSU (Laser Scanning Unit)
•
Troubleshooting
1) Perform ACR.
(Home > Machine Setup > General Settings > Image Management > Auto Color Registration)
2) Print ACR Report.
(Service Mode > Information > Print Reports > Auto Color Registration)
Succeed or Failed for ACR: [1152] → Registration cannot be adjusted by ACR.
a) Check if Skew data of ACR Report is changed.
b) Check if OPC surface of Y/M/C is OK. → Check if it is scratched or torn.
c) Print and check separated Y/M/C color and see if it is OK.
d) Find “Succeeded or Failed for ACR” from ACR report.
-
If the value is 1152 like the above report, ACR cannot be done. LSU need to be replaced.
-
Succeeded or Failed for ACR: [0] → ACR was performed OK [OK]
-
Succeeded or Failed for ACR: [1] → ACR was not performed OK [Fail]
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-265