
4. Troubleshooting
4.9.4. Adjusting the Scan Top Skew
1) Remove 2 screws. And then, remove the scan glass holder cover.
2) Lift the scan glass up and release it.
NOTE
Be careful not to contaminate the scan glass.
3) Adjust ‘R’, ‘S’ screws as the skew status.
For example,
a) If the top skew is like a below sample (@AS chart, 1.5mm clockwise direction skew), rotate ‘S’ screw one turn and
‘R’ screw a half turn in a clockwise direction.
NOTE
The combination of ‘S’ screw one turn and ‘R’ screw a half turn must be kept.
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-309