To do list
4. Disassembly and Assembly
124
4-35. Assembling Procedures of the CO2 Cylinder and Precautions
3. Rotate the Cylinder counterclockwise to remove it from the Regulator.
4. To install the new cylinder, follow the directions for installing a cylinder starting at Step 2.
5. Press the Sparkling Water button for 3 seconds to turn the Cylinder reset function on.
• If you replace the CO2 Cylinder during Sparkling Water Production (The Carbonation Level Icon
turns on in the order of 1 → 2 → 3 → 1.), wait until the refrigerator completes production before
turning the Sparkling Water Production function back on.
Because you interrupted production, the sparkling water may be over carbonated. We recommend
that you throw out the overly carbonated water.