5-1-7. Option TABLE
To do list
7) Temperature changing table of ice room
Set item
Ice Room Temp Shift
Reference
Fridge Room 7-SEG
Value
34
ex) If you want to change the ice room standard temperature to
+5
℉
(+2.5
℃
)
5. Check the installation status
5-1. Function for failure diagnosis
Setting value
FZ
Compartment
code
Temp.
compensation
0
0℉(0.0℃)
1
-
1℉(
-
0.5℃)
2
-
2℉(
-
1.0℃)
3
-
3℉(
-
1.5℃)
4
-
4℉(
-
2.0℃)
5
-
5℉(
-
2.5℃)
6
-
6℉(
-
3.0℃)
7
-
7℉(
-
3.5℃)
8
+1℉(+0.5℃)
9
+2℉(+1.0℃)
10
+3℉(+1.5℃)
11
+4℉(+2.0℃)
12
+5℉(+2.5℃)
13
+6℉(+3.0℃)
14
+7℉(+3.5℃)
15
+8℉(+4.0℃)
8) Temperature changing table of Ice Maker
Dropping Temperature
Set item
Ice Maker Dropping
Temperature
Reference
Fridge Room 7-SEG
Value
35
ex) If you want to change the mid drawer room temperature to
-2
℉
(-1.0
℃
)
Setting value
FZ
Compartment
code
Temp.
compensation
0
-
13℃
1
-
12℃
2
-
11℃
3
-
10℃
4
-
14℃
5
-
15℃
6
-
16℃
7
-
17℃
151