6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
238
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes
SOLUTION
The Over
Flow Error
occurs.
Water leaks out
from the Vent
Valve.
1. Even if the Mixing
Tank is filled up with
water, it does not
detect the Water Fill-
Up and water comes
out of the Vent.
2. Check it at the
Display Function of
Load Condition Mode.
: The Water Fill-Up is
not detected
(R-10-
ⓔ
).
Defective Housing
(
⑨
,
⑫
) Connection
Reconnect the Housing
⑨
and
⑫
Defective Display
Panel
Replace the Display
Panel
Defective Water
Level Sensor (No
Water Fill-Up
Detection)
Replace the Module
Water leaks at
the joints.
Open the Module and
check the marking area
on each Hose
No Hose Insertion
Insert the Hose
Check the water leak
area of each Hose.
Hose Scratch
Replace the Hose