Samsung mini DVM Series Service Manual Download Page 352

9-4

Samsung Electronics

RVXMHF

✳✳✳✳✳

High Temperature High Pressure Gas
High Temperature High Pressure Liquid
Low Temperature Low Pressure Gas

9-2 Heating Operation

Summary of Contents for mini DVM Series

Page 1: ... maintenance and installation Minimized shipping space Reduction of unit weight Various Control System Variable Scroll Comp is applied Overcomes the limit of connection place of indoor unit SERVICE Manual For more information Please access to our service web site http itself sec samsung co kr mini DVM Series DVM Plus2Series SYSTEMAIRCONDITIONER ...

Page 2: ...tions 2 13 2 2 1 Indoor Unit 2 13 2 2 2 Outdoor Unit 2 27 2 2 3 Accessory 2 35 13 Alignment and Adjustments 3 1 3 1 Error mode and check method 3 1 3 1 1 1 way 2 way cassette type Wall mounted type Prestige 3 1 3 1 2 4 way cassette type 3 3 3 1 3 Duct Type Low silhouette High pressure Built in 3 5 3 1 4 Ceiling type 3 7 3 2 Setting Option Setup Method 3 9 3 2 1 PCB option code input method 3 9 3 3...

Page 3: ...assette type 5 1 5 1 2 2 way cassette type 5 5 5 1 3 4 way cassette type 5 9 5 1 4 Mini 4 way cassette type 5 15 5 1 5 Duct type Low silhouette 5 19 5 1 6 Duct type High Low pressure 5 21 5 1 7 Duct type Built in 5 25 5 1 8 Duct type Slim1 5 29 5 1 9 Duct type Slim2 5 31 5 1 10 Wall mounted type Premium 5 33 5 1 11 Wall mounted type Prestige 5 39 5 1 12 Ceiling type 5 47 5 2 Outdoor Unit 5 51 5 2 ...

Page 4: ... 6 2 6 RVXVHT100G RVXFHT100G 6 90 6 2 7 RVXVHT120G RVXFHT120G 6 98 6 2 8 RVXVHT140G RVXFHT140G 6 107 6 3 Outdoor Power PCB 6 116 6 4 Outdoor CT PCB 6 119 17 Wiring Diagram 7 1 7 1 Indoor Unit 7 1 7 1 1 1 way cassette type 7 1 7 1 2 2 way cassette type 7 2 7 1 3 4 way cassette type 7 3 7 1 4 Mini 4 way cassette type 7 4 7 1 5 Duct type Low silhouette Built in 7 5 7 1 6 Duct type High Low pressure 7...

Page 5: ...3 1 MAIN PCB 1 8 9 8 3 2 MAIN PCB 2 8 10 8 3 3 POWER PCB 8 11 19 Refrigerant circuit Diagram 9 1 9 1 Cooling Operation 9 1 9 2 Heating Operation 9 4 9 3 A description of cycle function parts 9 7 10 PCB Diagram 10 1 10 1 Indoor Unit 10 1 10 1 1 1 way cassette type 10 1 10 1 2 2 way cassette type 10 3 10 1 3 4 way cassette type 10 5 10 1 4 Mini 4 way cassette type 10 7 10 1 5 Duct type Low silhouett...

Page 6: ...acking communication check indicated if abnormal 12 2 12 1 2 Reverse Phase Missing Phase Detection outdoor unit using 3 phase power indicated if abnormal 12 3 12 1 3 Compressor preheating indicated 12 5 12 2 Self Diagnosis by Indoor Unit LED Display Lamp Display 12 6 12 3 Self Diagnosis by Outdoor Unit Error Display 12 8 12 3 1 Error Display Method 12 8 13 Block Diagram 13 1 13 1 Indoor Unit 13 1 ...

Page 7: ...1 The setting of option switch 14 3 14 2 2 The function of key on the outdoor unit PCB 14 4 14 2 3 Test operation 14 6 14 3 Special Operation Mode DVM Plus2 Series 14 9 14 3 1 Refrigerant Collection Operation 14 9 14 3 2 Oil Collection Operation 14 14 14 3 3 Vacuum Preparing Operation 14 15 14 3 4 Filter Drier Equipping Method when Compressor is Breakdown 14 16 14 4 Information of refrigerant R410...

Page 8: ...nt pipe The design pressure of the unit is 4 1MPa Select appropriate material and thickness according to the regulations R410A is a quasi azeotrope of two refrigerants Make sure to charge liquid one when adding refrigerant If you charge gaseous refrigerant it may affect the capacity and reliability of the product as a result of change formation of the refrigerant Connect only the indoor units fit ...

Page 9: ...nd it may cause injury Fix the outdoor unit securely to prepare against strong wind or earthquake If the outdoor unit is not properly fixed it turns over and accidents may occur Install the cables with supplied cables firmly Fix them securely so that external force is not exerted to the terminal board If the connection or fixing is incomplete it can cause trouble with a heat generation electric sh...

Page 10: ...the electric wave though the cables are installed away from electric appliances Install the indoor unit away from lighting apparatus using the ballast If you use the wireless remote control it may not operate normally Do not install the air conditioner in following places The place where there is mineral oil or arsenic acid There is a chance that parts may get damaged due to burned resin The capac...

Page 11: ... and filter through Samsung s own technology Bacteria or mold cannot be propagated Double insulated indoor unit cabinet There is no condensation during cooling operation by attaching dual insulation material at the inside of the indoor cabinet thus there is no corrosion concern The compact design that requires less space reduces the installation space and all the corners become comfortable with th...

Page 12: ...ion can control the indicating time up to 1 000 2 000 hours by the application condition 3 Convenient Installation Compact Design This can be installed easily in a limited space due to compact design that requires less space Lift up drain pump The drain pump of the indoor unit can drain higher up to 550mm than the drain port thus the execution of drain pipe is more convenient Unit m Height A H Typ...

Page 13: ...2 Features of 4 way Cassette Type Air Conditioner With the ceiling installation type which winds come from 4 directions the space is cool equally and the nobility of the air conditioner is more upgraded Light compact body Antibacterial cooler Turbo fan Antibacterial purifying long life air filter Washable front grill Filter cleaning indicator Easy installation maintenance of front box ...

Page 14: ...ns thus it has faster and more equal cooling than stand or wall mounted type Space efficiency Different from other air conditioner installed a corner of a living room or a wall this is installed on a ceiling so separate installation space is not required Stylish design The trendy and noble design blends with any interior design so installation itself is beautiful With the compact size you can inst...

Page 15: ...t 3 way airflow when installing on the ceiling near the window while adopt 4 way airflow when installing on the central ceiling Fan speed adjustment Fan speed can be adjusted freely according to the 2 step fan speed controlling ceiling height 4 way cassette type cont 4 way pattern 3 way pattern 3 5m Possible to install up to 3 5m height by strong fan speed Classification Ceiling height H 2 7 3 5m ...

Page 16: ...eration thus there is no corrosion concern Antibacterial cooler filter Adopt the antibacterial cooler and filter through Samsung s own technology Bacteria or mold cannot be propagated in the inside Filter cleaning indicator The filter cleaning indicator on the body of the indoor unit and the wired remote controller shows the time to clean the polluted filter This function can control the indicatin...

Page 17: ...es easy to install and very versatile High Ceiling Operation Broader and wider blow supports up to 3 6 meters high Built in Drain Pump Product Specifications Samsung Electronics 2 7 2 1 3 Mini 4 way cassette Recover comfort to all the corners by strong cooling and heating capacity 1 Mini 4 way cassette Air Conditioner 260mm 575mm 575mm 9 12 18 21k 575mm 575mm 9 12 18 21k Company A Samsung 286mm ...

Page 18: ...on of the supply chamber and the flexible duct 2 Excellent Economic Efficiency Prominent economic efficiency By using one indoor unit for cooling and heating operation up to 6 rooms the economic efficiency is excellent while keeping the cooling and heating capacity Free installation Not restricted by room structure and the location of lighting fixtures Possible to attach a drain pump which is an o...

Page 19: ...re More wide and strong ventilation is possible by the high pressure fan of the indoor unit and duct Convenient arrangement of the air outlet to the fittest place by the high pressure fan is possible Duct type Built in Duct type Slim Duct type cont The Feature of Duct Installation 350mm Air Filter Supply Chamber ...

Page 20: ...rs Silver Nano filterTM The unit s outermost filter which is uniquely treated with an antibacterial agent catches very small dust particles in the air This is an image diagram Some parts may not be shown in actual size Silver Nano EvaporatorTM The new H Fin technology enhances the power of removing bacteria The heat exchanging function is upgraded It provides pure and fresh air similar to an air p...

Page 21: ... air conditioner doesn t lift up or transform when it is turned on and operated Therefore it maintains the consistent slim size of 145mm whether the air conditioner is turned on or off 3 Air Purifying System 4 Digital i The Digital i not only displays the current temperature but also the power and current operation mode New 145mm 145mm Off On Cross Fan Silver Nano EvaporatorTM Deodorizing filter A...

Page 22: ...ou want to install it on floor level the unit can be used in this configuration also Double Swing Airflow The Ceiling type installed in the corner blows in double ways It blows right and left at the same time It also blows up and down at the same time Or it can blow in just one direction very widely It will give multiple choices of air flow to maximize comfort Louver Heat exchanger 5way display Cr...

Page 23: ...35 PFS040WTVE PFS040WTVE PFS040WTVE Cross fan Cross fan Cross fan 13 14 16 5 8 6 0 7 0 7 5 7 5 8 0 0 18 0 20 0 23 35 40 45 EEV Electronic Expansion Valve 6 35 6 35 6 35 12 7 12 7 12 7 VP20 external diameter 26 internal diameter 20 15 15 15 18 18 18 970x180x390 970x180x390 970x180x390 1 168x302x467 1 168x302x467 1 168x302x467 3 5 3 5 3 5 6 2 6 2 6 2 1 180x35x460 1 180x35x460 1 180x35x460 1 259x144x...

Page 24: ...0 240 50 18 000 24 000 5 6 7 1 19 000 26 000 6 3 8 0 40 36 42 40 PFS040AVEB PFS040AVEB Cross Fan Cross Fan 14x2ea 14x2ea 14 16 14 16 0 38 0 40 70 75 EEV Electronic Expansion Valve 6 35 9 52 12 7 15 88 VP 25 external diameter 32 internal diameter 25 21 21 25 25 890x230x575 890x230x575 1 077x642x299 1 077x642x299 4 4 8 8 1 030x25x650 1 030x25x650 1 103x151x727 1 103x151x727 Yes Yes No No Yes Option ...

Page 25: ...6 58 72 85 16 0 18 1 16 0 18 1 26 1 28 4 28 3 30 9 28 9 32 3 0 5 0 5 0 71 0 73 0 78 110 110 160 164 172 EEV Electronic Expansion Valve 6 35 9 52 9 52 9 52 9 52 12 7 15 88 15 88 15 88 15 88 VP 25 external diameter 32 internal diameter 25 26 26 29 5 29 5 29 5 31 31 35 5 35 5 35 5 840x230x840 840x230x840 840x288x840 840x288x840 840x288x840 939x324x923 939x324x923 939x382x923 939x382x923 939x382x923 4...

Page 26: ...AUEA Turbo fan Turbo fan Turbo fan Turbo fan 55 55 55 55 11 2 12 9 11 2 12 9 11 7 13 6 12 2 14 5 0 5 0 5 0 52 0 55 88 88 93 97 EEV Electronic Expansion Valve 6 35 6 35 6 35 6 35 12 7 12 7 12 7 12 7 VP 25 external diameter 32 internal diameter 25 17 17 17 17 20 20 20 20 575x260x575 575x260x575 575x260x575 575x260x575 660x310x660 660x310x660 660x310x660 660x310x660 3 3 3 3 5 5 5 5 670x35x670 670x35x...

Page 27: ...04SAC Sirocco Sirocco Sirocco Sirocco 51 51 81 81 13 0 14 5 15 15 5 18 18 5 22 5 23 5 0 77 0 77 1 15 1 70 145 145 231 360 EEV Electronic Expansion Valve 6 35 6 35 9 52 9 52 12 70 12 70 15 88 15 88 VP 25 external diameter 32 internal diameter 25 41 41 41 41 44 44 44 44 1 340x260x600 1 340x260x600 1 340x260x600 1 340x260x600 1 514x389x749 1 514x389x749 1 514x389x749 1 514x389x749 Yes Yes Yes Yes No ...

Page 28: ...OSME 1604SAC S322 OSME 1604SAC S322 OSME 1604SAC S324 Sirocco Sirocco Sirocco 189 210 210 29 30 32 33 35 35 4 2 52 2 76 2 76 540 600 600 EEV Electronic Expansion Valve 9 52 9 52 9 52 15 88 15 88 15 88 VP 25 external diameter 32 internal diameter 25 66 66 66 77 77 77 1 110x390x650 1 110x390x650 1 110x390x650 1 329x512x829 1 329x512x829 1 329x512x829 Yes Yes Yes No No No Yes Option Yes Option Yes Op...

Page 29: ...DLH071E AVXDLH090E AVXDLH112E AVXDLH128E AVXDLH140E 1 220 240 50 24 300 31 000 38 000 44 000 48 000 7 1 9 0 11 2 12 8 14 0 27 300 34 100 43 000 47 000 54 000 8 0 10 0 12 5 13 8 16 0 42 44 42 44 40 44 42 44 43 44 OSME 2454SAC S331 OSME 2454SAC S331 OSME 1186SAC S332 OSME 2454SAC S331 OSME 2454SAC S331 Sirocco Sirocco Sirocco Sirocco Sirocco 175 175 118 175 214 33 34 33 34 29 30 33 34 36 37 1 6 1 6 ...

Page 30: ...Sirocco Sirocco Sirocco 39 42 44 53 63 8 2 8 7 9 2 9 7 10 10 5 16 5 17 18 8 19 3 0 5 0 55 0 57 0 76 0 9 110 120 125 150 180 EEV Electronic Expansion Valve 6 35 6 35 6 35 6 35 9 52 12 70 12 70 12 70 12 70 15 88 VP 25 external diameter 32 internal diameter 25 27 27 27 38 38 31 31 31 44 44 550x300x800 550x300x800 550x300x800 1 020x300x800 1 020x300x800 747x378x911 747x378x911 747x378x911 1 214x378x91...

Page 31: ...9 Yes Option Yes Option 9 600 2 8 11 000 3 2 38 35 YSK100 25 4SM Sirocco 27 8 8 10 3 0 4 80 6 35 12 7 26 31 900x199x600 1 124x315x713 Yes No Yes Option Yes Option Yes No 209 Yes Option Yes Option 12 300 3 6 13 600 4 0 38 35 Sirocco 27 11 0 11 2 0 4 80 6 35 12 7 26 31 900x199x600 1 124x315x713 Yes No Yes Option Yes Option Yes No 209 Yes Option Yes Option VP25 external diameter 32 internal diameter ...

Page 32: ...6 90 6 35 12 7 31 39 1 100x199x600 1 324x315x713 Yes No Yes Option Yes Option Yes No 209 Yes Option Yes Option 19 100 5 6 21 500 6 3 45 45 Sirocco 60 18 0 6 100 6 35 12 7 31 39 1 100x199x600 1 324x315x713 Yes No Yes Option Yes Option Yes No 209 Yes Option Yes Option 24 300 7 1 27 300 8 0 47 47 Sirocco 60 20 0 6 120 9 52 15 88 31 39 1 100x199x600 1 324x315x713 Yes No Yes Option Yes Option Yes No 20...

Page 33: ...Heating Cooling Heating WxHxD WxHxD Liquid Gas Type Rated Output Capacity Dehumidifying Air Volume Noise Power Consumption Operating Current Outer Dimension Weight Refrigerant Pipe Drain Hose Blower Type Motor AVXWPH022E AVXWPH028E AVXWPH036E 1 220 240 50 2 2 2 5 1 4 6 5 6 6 40 40 30 30 0 18 0 18 795x258x179 31 3x10 2x7 0 7 5 ø6 35x7 5 ø12 7x7 5 ø18x535 Cross fan steel 11 2ROW 10STEP EEV 2 8 3 2 1...

Page 34: ...x600 Cross fan steel 19 2ROW 15STEP EEV 5 6 6 3 2 5 13 3 13 4 48 48 50 50 0 30 0 30 1 080x315x205 42 5x12 4x8 1 13 ø6 35x7 5 ø12 7x7 5 ø18x600 Cross fan steel 19 2ROW 15STEP EEV 6 8 7 0 2 5 13 3 13 4 48 48 50 50 0 30 0 30 1 080x315x205 42 5x12 4x8 1 13 ø9 52x7 5 ø15 88x7 5 ø18x600 Cross fan steel 19 2ROW 15STEP EEV Heat pump kW kW h m3 min m3 min dB dB W W A A mm inch kg mmxL m mmxL m mmxL m W ø V...

Page 35: ...rant Pipe Drain Hose Blower Type Motor AVXWHH028E AVXWHH036E AVXWHH045E AVXWHH056E AVXWHH071E 1 220 240 50 2 8 3 2 1 4 7 0 7 3 40 40 30 30 0 18 0 18 950x268x165 37 4x10 6x6 5 9 0 ø6 35x7 5 ø12 7x7 5 ø18x920 Cross flow Resin steel 15 2ROW 12STEP EEV 3 6 4 0 1 9 8 2 8 8 43 43 35 35 0 19 0 19 950x268x165 37 4x10 6x6 5 9 0 ø6 35x7 5 ø12 7x7 5 ø18x920 Cross flow Resin steel 15 2ROW 12STEP EEV 4 5 5 0 2...

Page 36: ...50 18 000 24 000 5 6 7 1 19 000 26 000 6 3 8 0 43 40 45 40 OSME 254SAC OSME 254SAC Cross fan Cross fan 47 47 14 14 5 18 18 5 0 33 0 35 72 77 EEV Kit Electronic Expansion Valve 9 52 9 52 15 88 15 88 Internal diameter 18 Hose 22 22 26 26 1 000x200x650 1 000x200x650 1 074x294x726 1 074x294x726 Yes Yes No No Yes Option Yes Option Yes Option Yes Option Yes Yes No No Heat pump Btu h kW Btu h kW dB W m3 ...

Page 37: ...Net Gross Cooling Heating Length Height Cooling Capacity Heating Capacity COP Noise level Maximum number of connectable indoor units Minimum capacity index Maximum capacity index Power input Running current Power breaker MCCB ELB Fan Compressor Refrigerant Piping connections Dimensions WxHxD Weight Operation range Pipe length RVXMHF040E 4 0 12 5 14 5 3 33 4 05 61 63 7 50 130 3 75 3 58 19 0 18 0 30...

Page 38: ...765 330 0 350 0 5 C 43 C 20 C 21 C 170 50 40 HP ø V Hz kW kW dB ea kW kW A A A m3 min kg ø mm ø mm ø mm mm kg kg C C m m Outdoor Type Model Equivalent horsepower Power supply Performance Power Others Size Function Option Cooling Heating Cooling Heating Cooling Heating Type Air flow rate Type Model name Name Charge Control Liquid Gas Oil balance Net Gross Cooling Heating Length Height Cooling Capac...

Page 39: ...onnections Dimensions WxHxD Weight Pipe length RVXVHT080G RVXFHT080G 16 0 3 380 415 50 45 0 50 0 3 46 4 08 26 13 00 12 24 26 23 4 55 15 88 28 58 6 35 880 880 x1 646x765 250 0 250 0 265 0 265 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT100G RVXFHT080G 18 0 3 380 415 50 50 5 56 5 3 30 4 16 29 15 30 13 57 28 7 24 9 60 15 88 28 58 6 35 880 880 x1 646x765 2...

Page 40: ...0 61 5 69 0 3 14 4 18 36 19 60 16 52 34 1 32 70 15 88 28 58 6 35 1 200 880 x1 646x765 330 0 250 0 265 0 265 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT140G RVXFHT100G 24 0 3 380 415 50 68 0 76 5 3 08 4 21 40 22 10 18 16 39 5 34 2 75 15 88 28 58 6 35 1 200 880 x1 646x765 330 0 250 0 350 0 265 0 170 50 40 RVXVHT140G RVXFHT120G 26 0 3 380 415 50 73 5 82 ...

Page 41: ...h RVXVHT100G RVXFHT100G RVXFHT100G 30 0 3 380 415 50 84 0 94 5 3 18 4 15 48 26 41 22 78 47 1 40 5 90 19 05 31 75 6 35 880 880 880 x1 646x765 250 0 250 0 250 0 265 0 265 0 265 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT120G RVXFHT100G RVXFHT100G 32 0 3 380 415 50 89 5 100 5 3 15 4 11 48 28 40 24 44 49 8 46 1 95 19 05 31 75 6 35 1 200 880 880 x1 646x765...

Page 42: ...nning current Power breaker MCCB ELB Piping connections Dimensions WxHxD Weight Pipe length RVXVHT140G RVXFHT120G RVXFHT100G 36 0 3 380 415 50 102 5 115 0 3 17 4 10 48 32 30 28 08 57 9 54 110 19 05 38 10 6 35 1 200 1 200 880 x1 646x765 330 0 330 0 250 0 350 0 350 0 265 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT140G RVXFHT140G RVXFHT100G 38 0 3 380 41...

Page 43: ...0G RVXFHT120G 40 0 3 380 415 50 113 5 127 5 3 03 4 10 48 37 40 31 10 66 61 9 125 19 05 38 10 6 35 1 200 1 200 1 200 x1 646x765 330 0 330 0 330 0 350 0 350 0 350 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT140G RVXFHT140G RVXFHT140G 42 0 3 380 415 50 120 0 135 0 3 01 4 12 48 39 90 32 76 71 4 64 2 135 19 05 38 10 6 35 1 200 1 200 1 200 x1 646x765 330 0 3...

Page 44: ... MCCB ELB Piping connections Dimensions WxHxD Weight Pipe length RVXVHT140G RVXFHT120G RVXFHT100G RVXFHT100G 46 0 3 380 415 50 129 5 145 5 3 11 4 04 48 41 70 36 04 73 6 68 9 140 19 05 38 10 6 35 1 200 1 200 880 880 x1 646x765 330 0 330 0 250 0 250 0 350 0 350 0 265 0 265 0 170 50 40 HP ø V Hz kW kW ea kW kW A A A ø mm ø mm ø mm mm kg kg m m Outdoor Type RVXVHT140G RVXFHT140G RVXFHT100G RVXFHT100G ...

Page 45: ...tion pipe Liquid pipe Gas pipe MGKH181M1 1 way cassette Requisite Front Panel Cooling Cooling Heating MGGH1031M1 2 way cassette MGCH0951M3 4 way cassette MXD A13K116 MXD A13K200 MXD A16K200 MXD A22K200 MXD A13K216 MXD A13K300 MXD A16K213 MXD A16K300 Wall mounted Ceiling Option Distributor kit Below 4 0kW 1 room 5 2kW 9 0kW 1 room Below 4 0kW 2 rooms 5 2kW 9 0kW 2 rooms 5 2kW 7 2kW 2 rooms Below 4 ...

Page 46: ... Option Edition Electric Power Division System The high tech digital system displays accumulated amount of used power to divide power rate by each indoor unit MR AC10 Cooling MR AH10 Cooling Heating Cassette type Duct type Option Wireless Remote Control Individual control MRK A00 C U Duct type Option Wireless Remote Control Receiver Kit Wireless Remote Control Receiver MRW 10A C U Duct type Option...

Page 47: ...module for communication of DMS all products MCM A202 C U Indoor Unit all lines Option Centralized controller 16 rooms ON OFF MIM D00 Indoor Unit all lines Option DMS Control by room or zone Eeservation function Division of power Remote monitoring for power control MST P2W0 Indoor Unit all lines Option SNET i Control by room or zone Reservation function Division of power Remote monitoring for powe...

Page 48: ...MEMO 2 38 Samsung Electronics ...

Page 49: ...r unit for 2 minutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communi...

Page 50: ...ion 18 DISCHARGE high temperature 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Plot switch detection Peripheral control device option setting error EEPROM error EEPROM option error Indoor unit EEV defect Indoor u...

Page 51: ...unit for 2 minutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communica...

Page 52: ...etection 18 DISCHARGE high temperature 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Plot switch detection Peripheral control device option setting error EEPROM error EEPROM option error Indoor unit EEV defect Ind...

Page 53: ...inutes When communication error is for over 2 minutes 2 The indoor unit receives the communication error signal from the outdoor unit 3 The outdoor unit tracking 3 minutes error 4 When the outdoor unit transmits a communication error which is caused by difference between the number of the installation unit and the number of communication unit after completion of tracking When communication error i...

Page 54: ... 2nd detection 19 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Plot switch detection Peripheral control device option setting error EEPROM error EEPROM option error Indoor unit EEV defect Indoor unit EVAP IN OUT sensor breakaway ...

Page 55: ...nit communication error for more than 2 minutes 2 Indoor unit receiving the communication error from outdoor unit 3 Outdoor unit tracking 3 minute error 4 When sending the communication error from outdoor unit due to the mismatching of the communication numbers and installed numbers after completion of tracking communication error for more than 2 minutes Self diagnostic error including the indoor ...

Page 56: ...or of reverse phase 11 Compressor down due to 6th detection of freezing 12 Self diagnosis of condensation sensor G8 G9 13 Compressor down due to condensation ratio control Error of float switch Error of setting option switches for optional accessories EEPROM error EEPROM option error Displayed on appropriate indoor unit which is operating Displayed on outdoor unit On Flickering Off If you turn off...

Page 57: ... Step 2 Method If the first digit of remote controller shows 0 go to the step 3 If it shows 1 press the operation selection button one time to change it into 0 and then go to step 3 Step 3 Method Input the second digit of option code by pressing the temperature adjustment button up example 021E31142285 Result If 2 is displayed go to the step 4 whenever pressing the button 1 9 A B C D E F are lit i...

Page 58: ...e adjustment button down example 021E31142285 Result If 1 is displayed go to the step 5 Step 5 Method Input the fourth digit of option code by pressing the fan speed adjustment button example 021E31142285 Result If E displays go to step 6 SEG 5 Step 6 Method Input the fifth digit of option code by pressing the On timer button example 021E31142285 Result If 3 displays go to step 7 ...

Page 59: ...ays go to step 8 Step 8 Method After completion up to step 7 pressing mode button 1 7 steps are saved internally If the first number is 1 at the time it is correct So go to step 9 If wanting to see the screen of 2 7 steps press the mode button to make the first digit 0 Step 9 Method Input the eighth digit by pressing the temperature adjustment button up example 021E31142285 Result If 4 displays go...

Page 60: ... the temperature adjustment button down example 021E31142285 Result If 2 displays go to step 11 Step 11 Method Input the tenth digit by pressing fan speed adjustment button example 021E31142285 Result If 2 displays go to step 12 Step 12 Method Input the 11st digit by pressing the On timer button example 021E31142285 Result If 8 displays go to step 13 ...

Page 61: ...play of remote controller Operation mode SET TEMP fan speed displays Error If the On Off Timer and Fan indicator is flickering the wrong option code is input Put off the power of indoor unit and turn it on again and then input the option code again If the same error occurs it is the EEPROM is defective or not inserted Replace the PCB If all of On Off Timer Fan and Filter Sign indicator are flicker...

Page 62: ...4 0 0 0 0 0 0 0 2 2 2 2 2 2 2 2 2 2 2 4 4 0 2 3 3 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 3 1 1 1 3 2 3 3 3 3 3 2 2 2 2 2 0 0 c 1 4 6 8 0 0 0 0 0 b b b F 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E 2 A 3 3 b 9 3 5 6 5 5 7 2 6 1 3 3 0 0 8 d 0 1 2 0 0 0 0 0 3 3 3 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 A c 0 5 5 A E F 1 2 1 1 1 8 E d F F 0 0 AVXC1H022E AVXC1H028E AVXC1H036E AVXC2H056E AVXC2H07...

Page 63: ...rk 1 Front Grille Filter 1 Open the Front Grille by pushing the tabs on the Grille You must give attention when disassembling the Front Grille and must check the safety clips have been installed If you don t ensure them the Front Grille will drop suddenly and you will be hurt 2 Separate the Front Grille 1 Remove the safety clips 2 Open the Front Grille about 45 and pull it forward 3 Pull out the A...

Page 64: ...ronics Disassembly and Reassembly No Parts Procedure Remark 2 Front Panel 1 Disassemble the screws holding the Panel as shown picture 2 Separate the Front Panel pressing the 2 hooks on the both sides of the indoor unit ...

Page 65: ...Electronics 4 3 Disassembly and Reassembly No Parts Procedure Remark 3 Ass y Drain Panel 1 Disassemble screws for Ass y Drain Panel around as shown in pictures 2 Separate Ass y Drain Panel as shown in pictures ...

Page 66: ...Disassembly and Reassembly No Parts Procedure Remark 4 Ass y Control In 1 Separate the Control Cover after disassembling screws as shown in pictures 2 Separate the wire connection part of the Ass y Main PCB as shown in picture ...

Page 67: ...ng Electronics 4 5 Disassembly and Reassembly No Parts Procedure Remark 3 Disassemble screws of Case Control as shown in pictures 4 Disassemble indicating screw 5 Separate Ass y Case Control part pulling up ...

Page 68: ...bly and Reassembly No Parts Procedure Remark 6 Disassemble indicating screw and separate earth cable 7 Disassemble indicating screw and separate Terminal Cover as shown in pictures 8 Disassemble indicating screws as shown in pictures ...

Page 69: ...Parts Procedure Remark 5 Ass y Drain Panel Sub 9 Disassemble indicating screws of earth cable and indicating screw of Base Terminal 10 Separate Base Terminal as shown in picture 1 Separate Ass y Drain Panel Sub after disassemble the screws both side of it ...

Page 70: ...ly No Parts Procedure Remark 6 Ass y Evap 1 Disassemble the screws of Ass y Evap around 2 Disassemble indicating screws as shown in picture and separate Ass y Cabinet Side LF B 3 Separate Ass y Evap pulling up from the indoor unit as shown in picture ...

Page 71: ... 8 Ass y Cross Fan Ass y Drain Pump 1 Disassemble the screws of Cover Fan Motor and separate Cover Fan Motor 2 Separate Ass y Cross Fan as shown in picture 1 Disassemble indicating screws as shown in picture 2 Separate Drain Hose and separate Ass y Drain Pump as shown in pictures ...

Page 72: ... Push button 2 Separate the Front Grill 1 Open the Grill as shown in the picture 2 Separate the Grill fixing Safety Clip 3 Filter Separation 1 Pull back the hook at the Panel Grill and remove the Filter 4 Disassemble bolts and screws that are fixed to the body of the Indoor Unit 4 1 2 2 way cassette type ...

Page 73: ...rk 5 After removing screws separate the cover from the Panel as shown in the picture 6 Separate the Step Motor that connected to the Indoor Unit and Remote Control Receiving Part connector 7 Pull back the both side hooks of the Panel and separate the Panel from the Indoor Unit ...

Page 74: ...c Component part and separate the Sensor Wire and Holder 2 Separate the Case by pressing the hook 3 Separate the Terminal Block Ass y for connection of the power cable and the communication cable 4 Separate the fan Motor Connector Sensor Connector Drain Pump and Flat S W Connector 5 Remove the Electronic Component part from the Indoor Unit ...

Page 75: ...cs 4 13 No Parts Procedure Remark 3 Heat Exchanger 1 Remove screws from the Connection Pipe cover 2 Separate the Connection Pipe cover from the Indoor Unit 3 Remove 16 fixing screws from the Drain Pan 4 Separate the Drain Pan from the Indoor Unit ...

Page 76: ...4 Fan Motor 5 Remove 4 fixing screws from the Heat Exchanger 6 Remove the Drain Pump Sensor and separate the Heat Exchanger from the Indoor Unit 1 Remove the Cover Motor and fixing screws of Evap Guide 2 After removing the Cover Motor by pressing the hook separate the Evap Guide ...

Page 77: ...rain Pump 3 Separate the Motor and Fan from the Indoor Unit When separating the Fan from the Motor use a M3 wrench 1 Pull back the spring and separate the Drain Hose from the Pump 2 Disassemble 4 fixing screws fro the Drain Pump 3 After separate the Drain Pump connector separate the Pump ...

Page 78: ...6 Samsung Electronics No Parts Procedure Remark 6 7 Others Panel 1 When other parts separation is required perform as shown in the picture 1 Remove the Motor Holder that is fixed to the Panel 2 Separate the Step Motor from the Panel ...

Page 79: ...parate the PCB Case form the Panel 5 After removing the PCB fixing screws remove the PCB from the Case 6 Pull back the Blade to the Panel and separate the Blade starting from the opposite side of the Step Motor 7 For separation of Blade V after removing the fixed partition separate it by pulling back to the left and right ...

Page 80: ...Filter Air 1 Push the tap on the Front Grille to open it 2 Disassembly of Front Grille 1 Open the Front Grille at about 45 degrees and draw it forward 2 Disassemble the safety clip 3 Filter Disassembly 1 Draw the Dust Collecting Filter forward 2 Disassemble the Filter 4 1 3 4 way cassette type ...

Page 81: ...ening fixing bolts on the safety net remove the net 6 After loosening fixing bolts on the cover of the Electronic Component part separate the cover 7 Disassemble the 3 cables between the indoor unit and the Panel Stepping Motor Connector Remote control receiver connector In case of new Panel remove 2 pieces ...

Page 82: ...hooks on both sides of the indoor unit and disassemble the Front Panel 9 Take away the disassembled Panel out of the Indoor Unit 1 Disconnect all the indoor and outdoor cables connected to the Terminal Board 1 Disassemble the fan motor wire connector thermistor wire connector and drain pump wire connector 2 Disassemble the wire connector in the Capacitor ...

Page 83: ... Procedure Remark 3 Disassemble the ground wire 4 Disassemble the float switch wire connected to the Terminal Port F1 F2 5 Loosen the fixing bolts in the mark 6 Loosen a bolt in the arrow direction and inside 7 Disassemble the Drain Cushion from the Indoor Unit ...

Page 84: ... the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out...

Page 85: ...g Electronics 4 23 No Parts Procedure Remark 4 Ass y Drain Pump 12 Loosen nuts to disassemble the Motor 1 Loosen the bolts of the Drain Pump 2 Disassemble the hose from the Drain Pump 3 Disassemble the pump from the Indoor Unit Bracket ...

Page 86: ...No Parts Procedure Remark 5 Ass y Evap 1 Disassemble the cover pipe beside the Indoor Unit 2 Loosen the bolts fixing the Heat Exchanger to the indoor unit Base 3 Disassemble the fixing brackets of the Heat Exchanger to disassemble it from the Indoor Unit ...

Page 87: ...te Control Receiver Stepping Motor 1 After removing 3 fixing screws from the Remote Control Receiver separate it from the Panel 1 Separate it by loosening screws 2 Loosen the Motor fixing screws remove the Blade H 3 Separate the Motor from the Motor Housing and remove the Motor Connector ...

Page 88: ...lecting Filter 1 Push the tap on the Front Grille to open it 2 Disassembly of Front Grille 1 Open the Front Grille at about 45 degrees and draw it forward 2 Disassemble the safety Clip 3 Filter Disassembly 1 Draw the Dust Collecting Filter forward 2 Disassemble the Filter 4 1 4 Mini 4 way cassette type ...

Page 89: ...osen the 4 bolts slowly 5 Loosen the bolt of the front net to disassemble the safety net 6 Loosen the 3 bolts to uncover the Component Electric Box cover 7 Disassemble the 2 cables between the indoor unit and the Panel Stepping Motor Connector Receiving Display Unit Connector Option ...

Page 90: ...2 hooks on both sides of the indoor unit and disassemble the Front Panel 9 Take away the disassembled Panel out of the main body 1 Disconnect all the Indoor and Outdoor Cables Connected to the Terminal Board 1 Disassemble the Fan Motor wire connector thermistor wire connector and Drain Pump wire connector 2 Disassemble the wire connector in the Capacitor ...

Page 91: ...4 29 No Parts Procedure Remark 3 Disassemble the ground wire 4 Disassemble the Float Switch wire connected to the Terminal Port F1 F2 5 Loosen the 4 bolts in the mark 6 Disassemble the Base Control from the main body 7 Loosen the 4 bolts in the mark ...

Page 92: ...washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the washer Take out the ...

Page 93: ...msung Electronics 4 31 No Parts Procedure Remark 4 Pump 12 Loosen 4 bolts to disassemble the Motor 1 Loosen the 2 bolts of the Drain Pump 2 Disassemble the Hose from the Drain Pump 3 Disassemble the Pump from the main body Bracket ...

Page 94: ...ont Panel PCB Panel 1 Disassemble the cover pipe beside the main body 2 Disassemble the 1 fixing Bracket of the Heat Exchanger to disassemble it from the main body 1 Loosen 3 bolts fixing the Control C and then lift it up 2 Disassemble the Clamp 3 Loosen the bolt fixing the PCB to disassemble the PCB ...

Page 95: ...Disassembly and Reassembly Samsung Electronics 4 33 No Parts Procedure Remark 4 Disassemble the PCB Wire from the PCB 5 Disassemble the Bottom PCB and PCB ...

Page 96: ...o Parts Procedure Remark 7 Front Panel Stepping Motor 1 Loosen 3 bolts fixing the Control Panel and then lift it up 2 Disassemble the Stepping Motor and disassemble the link 3 Disassemble the Motor from the Bracket and disassemble the Motor Wire Connected ...

Page 97: ...ate Handle places by use of screw as shown in 2 2 Turn the Plate Handle by hand when removing the Filter Pre 3 When pulling the Filter Pre handle the Filter pre can be assembled Be sure to remove the cushion on the marked part after initial installation It cause the damage of noise 1 After disassembling places indicating screws detach Ass y Cover Bottom 4 1 5 Duct type Low silhouette ...

Page 98: ...rts Procedure Remark 2 Disassemble indicating screws 3 Detach the Sensor Holder from the Ass y Fan case 4 Detach from Ass y Control in the capacitor connection wire between the Motor Fan in and Housing Connector 5 Detach the Ass y Blower and Duct from the set ...

Page 99: ...e Remark 3 Ass y Control In 1 After disassembling indicating screw detach the Cover Control 2 Detach the Motor Fan in and Sensor Connector connected to PCB 3 Hold the Ass y Control In by hand to lift up a little and then release the status of hanging on the hanging slot ...

Page 100: ...crews to detach Ass y Drain Pan screws each at left and right side Work is possible when disassembling the Ass y Drain Pan 1 Disassemble indicating screws each at left and right side 2 Disassemble indicating screws 3 Disassemble indicating screws It is possible at the status of No 3 Ass y Control In disassembly at the time ...

Page 101: ...ctronics 4 39 No Parts Procedure Remark 4 After disassembling indicating screws 5 Pull the Cabinet Side LF RH by hand to disassemble 6 Separate indicating screws each at left and right side 7 Detach it from the set if the Ass y Evap pull up ...

Page 102: ... When connecting canvas to the discharge side 1 Disassemble indicating screws each at left and right side 2 Disassemble indicating screws each at upper and lower side After connecting canvas to the disassembled Ass y Holder Outlet 2 attach the Ass y Holder Outlet to the set in the reverse order ...

Page 103: ...t box Fan Motor 1 Disassemble screw for fixing the Electric Component box cover 2 Check internal connection of the Electric Component box 3 Separate the wire connection part of the Electric Component box indoor motor line indoor capacitor line temperature sensor line 1 Separate the screws fixed on the unit Base 4 1 6 Duct type High Low pressure ...

Page 104: ...r Drain Board 2 Separate Blower Ass y from the unit 1 Disassemble the screws on side part then Cabinet and the unit are separated 2 It is possible to clean the surface of Heat Exchanger and Drain Board 3 After cleaning Heat Exchangers and Drain Board check whether the drain exhaust are clogged ...

Page 105: ...lectronics 4 43 No Parts Procedure Remark 4 Cleaning a Filter 1 Remove bracket for fixing filter screws disassembly 2 Clean the Filter with removing downward 3 After cleaning the Filter insert and fasten it with Bracket for fixing Bracket ...

Page 106: ...In 1 Disassemble the indicating screws 2 Remove the Filter as shown in picture 1 Separate the control Cover Control after disassemble the indicating screws 2 Separate the wire connection part of the Ass y Control In Indoor motor wire indoor capacitor wire temperature sensor wire 4 1 7 Duct type Built in ...

Page 107: ...emark 3 Ass y Drain Panel 3 Disassemble the indicating screws 4 Hold the Ass y Control In by hand to lift up and remove it as shown in picture 1 Disassemble the indicating screws and separate the Cabinet Top 2 Disassemble the indicating screws and separate the Cover Holder ...

Page 108: ...bly 4 46 Samsung Electronics No Parts Procedure Remark 4 Ass y Evap 3 Separate the Ass y Drain Panel as shown in picture 1 Disassemble the indicating screw and separate wire and Cover Pipe 2 Disassemble the indicating screws ...

Page 109: ...mbly and Reassembly Samsung Electronics 4 47 No Parts Procedure Remark 5 Ass y Blower 3 Separate the Ass y Evap from the set 1 Disassemble the indicating screws 2 Pull up Ass y Blower and separate it from set ...

Page 110: ... Cabinet Top Motor Unscrew 8 screws 2 Disassemble 2 Cover Blower Uppers After unscrewing 2 screws Disassemble the Cover Blower Upper with pushing its hook 3 Disassemble the Cover Control Unscrew 2 screws 4 Disassemble Motor Wires connected to the inside of PCB and connected to the Capacitor 4 1 8 Duct type Slim ...

Page 111: ... 5 Disassemble the Motor earth wire connected to the Partition Unscrew a screw 6 Disassemble the band Motor for fixing the Motor Unscrew 2 screws 7 After disassembling the Motor and Blower for the set disassemble the Blower by use of 3mm wrench 1 Disassemble the Cabinet Top Evap Unscrew 11 screws ...

Page 112: ...et Unscrew 6 screws 3 Disassemble the Drain Cushion from the set The Evaporator should be disassembled after disassembling the Cover Control 1 3 and the Drain Pan 2 1 2 2 2 3 1 Disassemble the Cover Pipe that fixes the high low pressure Pipe Unscrew 2 screws 2 Disassemble the refrigerant temperature sensor Inlet air temperature sensor and EEV wire that connected to the inside of PCB ...

Page 113: ...Disassemble the Support Evap RH Unscrew 2 screws 5 Disassemble the Evaporator form the set The Control In should be disassembled after disassembling the Cover Control 1 3 1 Disassemble all Control Wires connected to the inside of PCB 2 In case of disassembling the PCB separately disassemble the PCB from the case with pushing the hook after unscrewing the screw Unscrew 1 screw ...

Page 114: ...sassembling the Case Control disassemble the Case Control from the set after unscrewing the screw connected to the direction of Blower Disassemble if after disassembling the Cabinet Top Motor 1 1 5 In case of disassembling the Trans Power unscrew the screw fixing on the Case Disassemble if after disassembling the case PCB 4 4 1 Disassemble the Bracket Outlet assembled on the Cabinet Unscrew 10 scr...

Page 115: ... then disassemble it by pulling it forwards 4 Open the upper Front Grille by pulling right and left sides of the Grille 5 Take the left and right Filter out 6 Loosen one of the right screw and detach the Terminal Cover 7 Detach the thermistor from the Front Grille 8 Loosen 5 fixing screws of Front Grille 9 Pull the lower left and right of discharge softly for the outside cover to be pulled out 4 1...

Page 116: ...e Panel Grille with the thumb to remove the hook And press the right of the upper side of the Panel Grille with the fingers And then disassemble the Panel Grille 1 Take all the connector of PCB upper side out Including Power Cord 2 Detach the outdoor unit connection wire from the Terminal Block 3 If pulling the main PCB up it will be taken out 1 Pull Tray Drain out from the Back Body ...

Page 117: ...de 2 Detach the Connection Pipe 3 Detach the Holder Pipe at the rear side 4 Loosen 3 fixing screws of right and left side 5 Detach the Heat Exchanger from the indoor unit 1 Loosen 2 fixing screws and detach the Motor Holder 2 Loosen the fixing screw of Fan Motor with a M3 wrench 3 Detach the Fan Motor from the Fan 4 Detach the Fan from the left Holder Bearing ...

Page 118: ...nditioner operation and shut off the main power 2 Detach the Front Grille after pushing out it 3 Loosen 1 of the right screw and detach the Ass y display 4 Loosen 1 of the right screw and detach the Terminal Cover 5 Detach the cover PCB DVM and thermistor from the Panel Front 4 1 10 Wall mounted type Prestige ...

Page 119: ...ain Heat Exchanger 6 Loosen 5 fixing screws of Panel Front 7 Unlock 2 hooks to fix Panel Front and Tray Drain 8 Unlock 2 hooks to fix Panel Front and Back Body 1 Detach the connected wire of Stepping Motor 2 Pull Tray Drain out from the Back Body 1 Loosen 1 fixing earth screw of right side ...

Page 120: ...nics No Parts Procedure Remark 2 Detach the Room Sensor 3 Detach the Holder Pipe at the rear side of the unit 4 Loosen 3 fixing screws of left Holder Evap 5 Loosen 1 fixing screw of right Holder Motor 6 Detach the Heat Exchanger from the indoor unit ...

Page 121: ...f right Holder control 2 Take all the connector of PCB upper side out Including Power Cord 3 Detach the outdoor unit connection wire from the Terminal Block 4 Pull the PCB up to detach 1 Loosen 2 fixing screws and detach the Motor Holder 2 Loosen 1 fixing screw of Fan Motor 3 Detach the Fan Motor from the Fan 4 Detach the Fan from the left Holder Bearing ...

Page 122: ...nics No Parts Procedure Remark 1 Electrical Part 1 Open the Grille by pressing 3 position center and both side 2 Remove the air Inlet Grille 3 Open the cover of Electrical Component Box by removing the screws center and both side 4 1 11 Ceiling type ...

Page 123: ...assembly and Reassembly Samsung Electronics 4 61 No Parts Procedure Remark 2 Fan Motor 1 Remove the screw and untie earth wire of Motor 2 Disconnect of housing of Motor Wire 3 Disconnect the Capacitor Wire ...

Page 124: ...ssembly 4 62 Samsung Electronics No Parts Procedure Remark 4 Remove the Guard Safety by removing the screws 5 Remove the upper case of Fan 2EA 6 Remove the screws what is fix the Motor 7 Remove the Fan and Motor assembly ...

Page 125: ...ure Remark 3 Drain Pan 8 Loosen the set screw using 3mm wrench 9 Remove the Fan 1 Disconnect the Display PCB wire as shown in picture white housing 2 Disconnect the Step Motor wire as shown in picture blue housing 3 Disassemble the Hanger Bracket by removing the screw ...

Page 126: ...nics No Parts Procedure Remark 4 Remove the screws of Front Side 5 Disassemble the assembly Front Cover Part 6 Disconnect the Step Motor wire as shown in picture 7 Remove the wire clamp fixed in Base Part 8 Remove the Front Cover assembly completely ...

Page 127: ...ung Electronics 4 65 No Parts Procedure Remark 9 Remove the screw what is fix with Base Part and Drain Pan upper side 2EA 10 Remove the screw what is fix with Base Part and Drain Pan lower side 2EA 11 Remove the Drain Pan completely ...

Page 128: ... 1 Disconnect the thermistor wire as shown in picture white housing 2 Remove the screws shown in picture 3 Remove the screws shown in picture and remove Plastic Part white 4 Remove the screws shown in picture and remove Steel Bracket 5 Disassemble the screws Steel Plate in rear side of unit ...

Page 129: ...Disassembly and Reassembly Samsung Electronics 4 67 No Parts Procedure Remark 6 Remove the screws as shown in picture 7 Remove Plastic Cover as shown in picture 8 Remove the Evaporator assembly ...

Page 130: ...side of Front Cover assembly as shown in picture 2 Remove the screws as shown in picture 3 Disassemble the Blade and Stepping Motor assembly and remove the screws Stepping Motor 1 Remove the screws in rear side of Front Cover assembly as shown in picture 2 Disassemble Display PCB assembly and disconnect wire 3 Disassemble the Display PCB ...

Page 131: ...ung Electronics 4 69 4 2 Outdoor Unit 4 2 1 4 5 6HP No Parts Procedure Remark 1 Outdoor 1 Outdoor unit of a package airconditioner 2 Separate a front tightening part 3 Separate the tightening part from side ...

Page 132: ... the power cable after turn off the unit 2 Remove the Top Cover 3 Remove the Control Box cover 4 Pull out the assembly cable 5 Remove the side of Cabinet 6 Remove the front side of Cabinet When assembling the parts check whether each parts and Electrical Connector fixed firmly 1 Remove nut flanges Turn screw leftward but turn right if you want to remove 2 Disassemble Propeller Fans ...

Page 133: ...Disassembly and Reassembly Samsung Electronics 4 71 No Parts Procedure Remark 1 Control In 1 Remove fixing screw from the Cabinet 2 Separate the Cabinet from the Outdoor Unit 4 2 2 8 10HP ...

Page 134: ...Disassembly and Reassembly 4 72 Samsung Electronics No Parts Procedure Remark 3 Separate the Electrical Component Box from the Outdoor Unit ...

Page 135: ...3 No Parts Procedure Remark 2 Motor Fan 1 Remove fixing screw from the Bell Mouth 2 Separate the Bell Mouth 3 Remove fixing bolt from the Fan 4 Separate the Fan from the Outdoor Unit 5 Remove fixing screw and 6 After removing screws separate the Motor ...

Page 136: ...Disassembly and Reassembly 4 74 Samsung Electronics No Parts Procedure Remark 1 Control In 1 Remove fixing screw from the Cabinet 2 Separate the Cabinet from the Outdoor Unit 4 2 3 12 14HP ...

Page 137: ...Disassembly and Reassembly Samsung Electronics 4 75 No Parts Procedure Remark 3 Separate the Electrical Component Box from the Outdoor Unit ...

Page 138: ...s No Parts Procedure Remark 2 Motor Fan 1 Remove fixing screw from the Bell Mouth 2 Separate the Bell Mouth 3 Remove fixing bolt from the Fan 4 Separate the Fan from the Outdoor Unit 5 Remove fixing screw and 6 After removing screws separate the Motor ...

Page 139: ...Samsung Electronics 5 1 1 4 5 15 23 16 19 17 18 6 20 21 8 14 2 22 2 25 24 3 7 14 1 14 14 3 11 12 13 10 9 5 Exploded Views and Parts List 5 1 Indoor Unit 5 1 1 1 way cassette type Body ...

Page 140: ...ARING ASS Y CROSS FAN MOTOR FAN IN HOUSING MOTOR COVER FAN MOTOR CASE CONTROL ASS Y MAIN PCB IN COVER CONTROL ASS Y EVAP ASS Y EVAP SPACER EVAP THERMISTOR ASS Y THERMISTOR EVAP BRACKET TERMINAL BASE TERMINAL TERMINAL BLOCK TERMINAL BLOCK COVER TERMINAL ASS Y DRAIN PAN ASS Y DRAIN PAN SUB ASS Y SENSOR FLOAT ASS Y PCB SURGE ABSORBER HOSE DRAIN ASS Y CABI SIDE LF ASS Y ASS Y PS V0 FUJIKOKI EPS ASS Y ...

Page 141: ...Exploded Views and Parts List Samsung Electronics 5 3 4 6 3 1 5 7 8 10 9 11 2 1 way cassette type cont Panel ...

Page 142: ...0A05 HIPS UL94 V0 HIPS UL94 V0 HIPS UL94 V0 HIPS UL94 V0 PP DB63 00164A DB66 00160A DB66 00157A DB63 00163A DB93 00374A DB93 01021A DB31 10153D DB61 00535A DB64 00234E DB66 00159A DB64 00243B DB64 00244A 1 2 3 4 5 6 7 8 9 10 11 COVER VALVE BLADE V LINK BLADE COVER PCB CASE DISPLAY PCB ASS Y DISPLAY PCB ASS Y STEP MOTOR HOLDER MOTOR PANEL FRONT BLADE H GRILLE FRONT GRILLE AIR INLET 1 10 2 1 1 1 1 1...

Page 143: ...loded Views and Parts List Samsung Electronics 5 5 3 2 11 1 5 12 8 9 5 1 5 2 3 1 3 2 1 3 1 1 1 5 4 20 23 22 8 9 12 18 16 17 19 13 24 21 10 11 14 15 25 7 6 1 4 1 2 1 7 1 6 1 8 5 1 2 2 way cassette type Body ...

Page 144: ...IDE LF ASS Y EVAP ASS Y EVAP ASS Y TUBE COLLECTOR ASS Y TUBE COLLECTOR ASS Y INLET PART ASS Y INLET PART ASS Y C F FAN MOTOR ASS Y ASS Y COVER MOTOR ASS Y CASE MOTOR ASS Y SENSOR FLOAT ASS Y COVER EVAP GUIDE ASS Y CASE FAN SIDE SUB ASS Y BEARING GUIDE CONTROL DRAIN PUMP HOLDER DRAIN PUMP RUBBER DRAIN PUMP ASS Y DRAIN SOCKET BAND RING CUSHION BODY CLIP BRUSH CABINET BASE CABI SIDE RH CABI SIDE LF H...

Page 145: ...Exploded Views and Parts List Samsung Electronics 5 7 18 13 7 11 12 2 3 17 15 16 19 9 6 10 8 20 1 14 4 5 2 way cassette type cont Panel ...

Page 146: ... 00415A DB66 00402A DB66 00416A DB66 00755A DB63 00676A DB70 00031A DB31 10153D DB61 00535A DB39 00874C DB39 00874B DB93 01666A DB39 00875A DB64 00745A DB64 00746A DB61 01238A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PANEL FRONT GRILLE FRONT FILTER INLET AIR CASE OUTLET AIR BLADE H BLADE V LINK BLADE V LATCH DC COVER PANEL PLATE HANGER MOTOR STEP HOLDER MOTOR C W MOTOR STEP LONG C W MOTO...

Page 147: ...Exploded Views and Parts List Samsung Electronics 5 9 1 2 4 7 5 6 8 9 3 10 11 12 13 14 15 17 24 24 18 19 16 21 20 27 22 26 25 28 29 30 31 32 33 34 5 1 3 4 way cassette type Body 5 6kW 7 1kW ...

Page 148: ...CUSHION NUT HEXAGON BRACKET WASHER FAN ASS Y FAN TURBO ASS Y CABINET FRONT ASS Y CABINET BACK CABINET SIDE ASS Y COVER PIPE ASS Y HOSE DRAIN ASS Y COVER DRAIN ASS Y EVAP UNIT ASS Y EVAP UNIT PARTITION FRONT EVAP HOLDER EVAP ASS Y BASE CUSHION CUSHION FAN CLIP BRUSH ASS Y SENSOR FLOAT BRACKET SWITCH PUMP DRAIN SCREW MACHINE RUBBER PUMP MOTOR FAN CABINET BASE HIPS V0 HIPS HB DC17 AC230V ASS Y 250V 2...

Page 149: ...Exploded Views and Parts List Samsung Electronics 5 11 1 2 4 7 5 6 8 9 3 10 11 12 13 14 15 16 18 25 24 19 20 17 22 21 28 23 27 26 29 30 31 32 33 34 35 4 way cassette type cont Body 11 2kW 14 0kW ...

Page 150: ...CABINET FRONT ASS Y CABINET BACK CABINET SIDE ASS Y COVER PIPE ASS Y HOSE DRAIN ASS Y COVER DRAIN ASS Y EVAP UNIT PARTITION FRONT EVAP HOLDER EVAP ASS Y BASE CUSHION CUSHION FAN CLIP BRUSH ASS Y SENSOR FLOAT BRACKET SWITCH PUMP DRAIN SCREW MACHINE RUBBER PUMP MOTOR FAN MOTOR FAN MOTOR FAN CABINET BASE HIPS V0 HIPS HB DC17 AC230V ASS Y 250V 20A 4P 250V 20A 4P PP BLK SGCC M T1 0 3000nF 10 5 450V BK ...

Page 151: ...Exploded Views and Parts List Samsung Electronics 5 13 28 28 16 15 30 28 1 18 13 12 14 31 11 7 17 28 28 23 21 22 10 28 18 30 29 29 4 5 6 8 29 3 51 26 9 27 19 20 25 28 2 24 4 way cassette type cont Panel ...

Page 152: ... ASS Y 1 SA 13 WASHER 1 SNA 14 DB69 00947A CUSHION IN EPS 4 SNA 15 DB69 00948A CUSHION OUT EPS 4 SNA 16 DB63 01014B COVER A HIPS 1 SNA 17 DB63 01015B COVER B HIPS 1 SNA 18 DB63 01016B COVER C HIPS 2 SNA 19 DB64 01144B GRILLE AIR INLET HIPS 1 SNA 20 DB74 00002A FILTER AIR PP 1 SA 21 DB64 01145A KNOB SLIDE HIPS 2 SNA 22 DB67 00030A SPRING KNOB STS304 2 SNA 23 DB63 01036A COVER KNOB HIPS 2 SNA 24 DB7...

Page 153: ...Exploded Views and Parts List Samsung Electronics 5 15 31 8 15 16 12 16 11 17 21 5 4 1 2 9 10 6 18 7 3 14 13 20 19 24 26 27 28 29 30 23 25 22 33 32 5 1 4 Mini 4 way cassette type Body ...

Page 154: ...E ASS Y COVER DRAIN GUIDE EVAP ASS Y EVAP UNIT ASS Y EVAP UNIT PUMP DRAIN RUBBER PUMP BRACKET PUMP ASS Y BASE CUSHION MOTOR FAN BRACKET MOTOR IN GROMMET MOTOR ASS Y CABI BASE GUARD SAFETY THERMISTOR EVAP IN ASS Y DRAIN HOSE INSTALL ABS V0 T2 0 MINI 4WAY CASSETTE 1 L 2 N Vc Vc F1 F2 V1 V2 F3 F4 450VAC 3 5uF SGCC M T1 0 103AT 20 100 C ABS V0 T2 0 MINI 4WAY CASSETTE SAN GF20 MINI 4WAY CASSETTE MINI 4...

Page 155: ...Exploded Views and Parts List Samsung Electronics 5 17 30 19 2 15 3 17 27 18 31 13 1 14 9 20 22 21 32 8 29 7 6 11 25 26 16 10 12 24 23 4 5 33 28 Mini 4 way cassette type cont Panel ...

Page 156: ... POM NTR 2 SA 14 DB61 02488A BUSH MINI POM NTR 8 SA 15 DB65 10074D CLAMP CABLE DA 4N 2 SA 16 DB65 00023A CLIP WIRE ASS Y L130mm 1 SA 17 DB63 01364A COVER A ABS V0 BLK 1 SA 18 DB63 01366A COVER B ABS V1 BLK 2 SA 19 DB63 01377A COVER C ABS V2 BLK 1 SA 20 DB63 01036A COVER KNOB HIPS UL94 HB WHT 2 SA 21 DB64 01145A KNOB SLIDE HIPS 94HB HG 0760 WHT 2 SA 22 DB67 00030A SPRING KNOB STS304 T0 5 2 SA 23 DB...

Page 157: ...Exploded Views and Parts List Samsung Electronics 5 19 5 1 5 2 5 3 5 4 5 5 5 6 19 1 19 2 19 3 19 4 19 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 20 21 18 19 5 1 5 Duct type Low silhouette ...

Page 158: ...N ASS Y CABI INLET LF ASS Y CABI INLET LF PLATE HANGER LF ASS Y EVAP ASS Y EVAP ASS Y CABI INLET RH ASS Y CABI SIDE RH PLATE HANGER RH CABINET SIDE RH B ASS Y HOLDER OUTLET ASS Y COVER BOTTOM PLATE HANDLE FILTER PRE COVER CONTROL ASS Y CONTROL IN ASS Y CONTROL IN ASS Y CASE CONTROL ASS Y PCB MAIN IN TERMINAL BLOCK 6P CAPACITOR CAPACITOR TERMINAL BLOCK 4P THERMISTOR ASS Y COVER BOTTOM BRACKET SGCC ...

Page 159: ...Exploded Views and Parts List Samsung Electronics 5 21 5 8 1 8 5 8 3 8 7 8 8 2 8 6 4 10 2 10 4 10 6 8 4 7 1 7 2 6 10 1 9 3 7 9 2 10 7 10 1 10 8 10 3 10 5 5 1 6 Duct type High Low pressure ...

Page 160: ...L SGCC M T0 8 1 1 SNA 8 2 DB26 10065B TRANS POWER 230V 50Hz 1 1 SA 8 3 DB65 00004H TERMINAL BLOCK 6P 6p 1 1 SA 8 4 DB65 00004C TERMINAL BLOCK 4P 4p 1 1 SA 8 5 DB93 03260A ASS Y PCB MAIN DUCT PCB 1 1 SA 8 6 DB61 40291B HOLDER WIRE PP BLK 2 2 SNA 8 7 DB63 00186A COVER CONTROL SGCC M T0 8 1 1 SNA 9 DB90 01513A ASS Y BRACKET OUTLET DUCT TYPE 2 2 SA 10 DB94 00586G ASS Y BLOWER DUCT TYPE 1 SNA DB94 0058...

Page 161: ... SA 8 1 DB61 00451A CASE CONTROL SGCC M T0 8 1 SNA 8 2 DB26 10065B TRANS POWER 230V 50HZ 1 SA 8 3 DB65 00004H TERMINAL BLOCK 6P 6p 1 SA 8 4 DB65 00004C TERMINAL BLOCK 4P 4p 1 SA 8 5 DB93 03260A ASS Y PCB MAIN DUCT PCB 1 SA 8 6 DB61 40291B HOLDER WIRE PP BLK 2 SNA 8 7 DB63 00186A COVER CONTROL SGCC M T0 8 1 SNA 9 DB90 01513A ASS Y BRACKET OUTLET DUCT TYPE 2 SA 10 DB94 00586K ASS Y BLOWER DUCT TYPE ...

Page 162: ...L SGCC M T0 8 1 1 SNA 8 2 DB26 10065B TRANS POWER 230V 50HZ 1 1 SA 8 3 DB65 00004H TERMINAL BLOCK 6P 6p 1 1 SA 8 4 DB65 00004C TERMINAL BLOCK 4P 4p 1 1 SA 8 5 DB93 03260A ASS Y PCB MAIN DUCT PCB 1 1 SA 8 6 DB61 40291B HOLDER WIRE PP BLK 2 2 SNA 8 7 DB63 00186A COVER CONTROL SGCC M T0 8 1 1 SNA 9 DB90 01513A ASS Y BRACKET OUTLET DUCT TYPE 2 2 SA 10 DB94 00586K ASS Y BLOWER DUCT TYPE 1 SNA DB94 0058...

Page 163: ...0 6 7 30 5 24 27 28 29 25 30 3 30 2 11 14 21 23 22 5 1 7 Duct type Built in 2 2kW 4 0kW Options No Code No Description Specification Remark Q TY MDP 075SB MDP 07SBU SA SNA SNA SA 31 32 33 34 DB67 00145A DB69 00137B DB61 00697A DB66 00058C HOSE DRAIN BAND RING BRACKET DRAIN PUMP PUMP DRAIN EPTM T1 5 STS304 T1 5 ABS UL94 VO ASS Y 1 1 1 1 1 1 1 1 ...

Page 164: ...BRACKET EVAP RH ASS Y TUBE EVAP OUT ASS Y TUBE EVAP IN VALVE EXPANSION COIL ASS Y DRAIN PAN CABINET TOP FILTER ASS Y COVER PIPE ASS Y CABI SIDE RH HOLDER PIPE COVER HOLDER COVER BRACKET COVER DRAIN PUMP ASS Y CONTROL PART COVER CONTROL ASS Y CASE CONTROL TRANS POWER CASE PCB OUT ASS Y PCB MAIN IN TERMINAL BLOCK 4P TERMINAL BLOCK 6P CAPACITOR CAPACITOR CAPACITOR HOLDER WIRE ASS Y ASS Y ASS Y SGCC M...

Page 165: ...0 20 1 14 15 18 29 6 7 11 35 13 8 9 4 31 32 33 26 34 Options No Code No Description Specification Remark Q TY MDP 075SB MDP 075SBU SA SNA SNA SA 31 32 33 34 DB67 00145A DB69 00137B DB61 00697A DB66 00058C HOSE DRAIN BAND RING BRACKET DRAIN PUMP PUMP DRAIN EPTM T1 5 STS304 T1 5 ABS UL94 VO ASS Y 1 1 1 1 1 1 1 1 Duct type Built in cont 5 6kW 7 2kW ...

Page 166: ...SS Y EVAP BRACKET EVAP LF BRACKET EVAP RH ASS Y TUBE EVAP OUT ASS Y TUBE EVAP OUT ASS Y TUBE EVAP IN ASS Y TUBE EVAP IN VALVE EXPANSION COIL ASS Y DRAIN PAN CABINET TOP FILTER ASS Y COVER PIPE ASS Y CABI SIDE RH HOLDER PIPE COVER HOLDER COVER BRACKET COVER DRAIN PUMP ASS Y CONTROL PART COVER CONTROL ASS Y CASE CONTROL TRANS POWER CASE PCB OUT ASS Y PCB MAIN IN TERMINAL BLOCK 4P TERMINAL BLOCK 6P C...

Page 167: ...Exploded Views and Parts List Samsung Electronics 5 29 23 8 13 9 12 14 2 16 18 17 1 6 15 21 11 24 25 4 5 22 10 3 8 7 19 20 23 6 23 4 23 5 23 3 23 7 23 1 23 8 23 2 5 1 8 Duct type Slim1 ...

Page 168: ...YA 18 DB31 00312A MOTOR SINYA SSR PID 19 DB67 00565A BLOWER ASS Y ABS TORSIONAL BUSH 20 DB90 01947A ASS Y CASE BLOWER UPPER ASS Y 21 DB90 01948A ASS Y CASE BLOWER BOTTOM ASS Y 22 DB94 00716A ASS Y DRAIN PAN ASS Y 23 DB93 03321A ASS Y CONTROL IN ASS Y 23 1 DB90 01941A ASS Y CASE CONTROL ASS Y 23 2 DB61 02287A CASE PCB ABS T2 5 23 3 DB63 01237A COVER CONTROL SGCC M T0 5 23 4 DB65 00105L TERMINAL BLO...

Page 169: ...Exploded Views and Parts List Samsung Electronics 5 31 8 10 9 13 11 32 16 22 21 27 28 20 23 24 19 17 3 18 26 25 5 8 4 30 30 1 30 6 30 5 30 2 33 30 4 30 3 12 29 6 7 14 31 15 2 1 34 5 1 9 Duct type Slim2 ...

Page 170: ...M T0 8 1 1 SA 16 DB94 00809A ASS Y PARTITION SGCC M T1 0 1 1 SA 17 DB61 02282A BRACKET MOTOR SGCC M T2 0 1 1 SA 18 DB97 03800A BAND MOTOR SINYA 1 1 SA 19 DB31 00314A MOTOR SINYA 50Hz 1 1 SA 20 DB66 01007A MOTOR SHAFT SINYA 1 1 SNA 21 DB94 00759A MOLD BEARING ASS Y 1 1 SA 22 DB67 00581A CAP BEARING SGCC M T0 8 1 1 SNA 23 DB73 00285A RUBBER SHAFT CR V0 1 1 SNA 24 DB96 04902A COUPLER ASS Y 1 1 SA 25 ...

Page 171: ...ded Views and Parts List 4 6 15 1 15 3 15 2 15 5 15 4 15 6 2 11 5 1 1 1 2 1 1 3 1 1 4 1 1 5 1 1 6 15 1 4 1 3 1 2 1 1 1 1 1 3 3 1 3 2 7 10 7 2 7 3 7 1 8 9 13 14 12 16 5 1 10 Wall mounted type Premium AVXWPH022E AVXWPH028E AVXWPH036E ...

Page 172: ... FILTER PRE LF PP 1 1 4 DB63 00586E FILTER PRE RH PP DB63 00591F FILTER PRE RH PP 1 2 DB92 00540A ASS Y GRILLE LOW ASS Y DB92 00538A ASS Y GRILLE LOW ASS Y 1 3 DB96 03801B ASS Y EVAPORATOR TOTAL ASS Y DB96 03796B ASS Y EVAPORATOR TOTAL ASS Y 1 3 1 DB96 03800A ASS Y EVAPORATOR ASS Y DB96 03797B ASS Y EVAPORATOR ASS Y 1 3 2 DB67 00051A SPACER EVAP LOW PVC 1 4 DB95 00367E ASS Y FILTER BIO ASS Y 1 5 D...

Page 173: ... HOLDER PIPE HIPS 1 15 DB94 00468B ASS Y TRAY DRAIN ASS Y DB94 00465A ASS Y TRAY DRAIN ASS Y 1 15 1 DB63 00587A TRAY DRAIN HIPS DB63 00592A TRAY DRAIN HIPS 1 15 2 DB94 00062E ASS Y DRAIN HOSE ASS Y 1 15 3 DB61 01103A BLADE H HIPS DB61 01125A BLADE H HIPS 1 15 4 DB61 01104A BLADE V PP DB61 01126A BLADE V PP 3 15 5 DB95 20138A ASS Y MOTOR STEPPING ASS Y 1 15 6 DB63 00634A GUARD SAFETY WIRE STS27 DB6...

Page 174: ...MEMO 5 36 Samsung Electronics ...

Page 175: ...and Parts List Samsung Electronics 5 37 4 6 2 8 5 1 12 3 7 10 13 1 1 2 1 1 3 1 1 4 1 1 5 1 1 6 1 4 1 3 1 1 1 1 1 12 4 12 2 12 1 12 5 12 3 12 6 7 5 7 4 7 3 7 2 7 6 7 7 7 1 7 8 1 2 11 9 AVXWPH045E AVXWPH056E AVXWPH071E ...

Page 176: ...TERMINAL HIPS 1 1 1 SA 6 DB93 03016N ASS Y REMOCON ASS Y 1 1 1 SA 7 DB94 00531A ASS Y BACK BODY ASS Y 1 1 1 SA 7 1 DB94 00040J ASS Y CROSS FAN ASS Y 1 1 1 SA 7 2 DB60 20011A BOLT SPECIAL M6 1 1 1 SA 7 3 DB31 10151C MOTOR FAN IN 1 1 1 SA 7 4 DB61 01135A BACK BODY HIPS 1 1 1 SNA 7 5 DB61 01136A HOLDER MOTOR PP 1 1 1 SNA 7 6 DB63 00580A COVER IONIZER HIPS 1 1 1 SA 7 7 DB73 00128A RUBBER BEARING 1 1 1...

Page 177: ... Electronics 5 39 10 12 16 11 2 5 13 19 20 21 15 7 22 22 1 3 6 17 14 1 18 9 4 8 23 14 6 14 1 1 1 1 2 9 2 9 3 2 5 22 2 3 2 3 4 3 1 3 3 2 1 2 6 2 5 1 2 4 2 2 2 3 9 1 14 5 14 2 14 3 14 4 5 1 11 Wall mounted type Prestige AVXWHH028E AVXWHH036E ...

Page 178: ...1 1 6 DB61 02050A HOLDER EVAP ABS 1 1 7 DB61 02052A HOLDER MOTOR PP 1 1 8 DB93 03659B ASS Y CONTROL IN ASS Y 1 1 9 DB96 05269D ASS Y EVAP TOTAL ASS Y 1 DB96 05269C ASS Y EVAP TOTAL ASS Y 1 9 1 DB60 00198A SPACER EVAP MID PVC 1 1 9 2 DB60 00203B SPACER EVAP UP PVC 1 1 9 3 DB96 05313B ASS Y EVAP FP1 3 H FIN 2x12 1 DB96 05313A ASS Y EVAP FP1 5 H FIN 2x12 1 10 DB67 60030A SPRING SENSOR STS 301 1 1 11 ...

Page 179: ...15A PLATE CONTACT SUS 304 1 1 19 DB70 00516A PLATE CONTROL IN SGCC M 1 1 20 DB93 03016R ASS Y REMOCON ARH 1315 1 1 21 DB92 00643C ASS Y GRILLE ASS Y 1 1 22 DB90 01829J ASS Y COVER DISPLAY ASS Y 1 1 22 1 DB63 01108A COVER DISPLAY PC 1 1 22 2 DB64 01276A INLAY DISPLAY ACRYL 1 1 23 DB90 01920A ASS Y COVER CONTROL ASS Y 1 1 AVXWHH028E AVXWHH036E SA SNA SNA SA SA SNA SNA SNA SNA ...

Page 180: ...MEMO 5 42 Samsung Electronics ...

Page 181: ...rts List Samsung Electronics 5 43 10 12 16 11 5 13 19 20 15 7 21 21 1 3 6 17 14 1 18 9 4 8 22 14 6 14 1 1 1 1 2 24 2 5 21 2 3 2 3 4 3 1 3 3 2 1 2 6 2 5 1 2 4 2 2 2 3 23 14 5 14 2 14 3 14 4 2 AVXWHH045E AVXWHH056E AVXWHH071E ...

Page 182: ...1 6 DB61 02194A HOLDER EVAP ABS 1 1 1 7 DB94 00727A ASS Y HOLDER MOTOR ASS Y 1 1 1 8 DB93 03660B ASS Y CONTROL IN ASS Y 1 1 1 9 DB96 05264A ASS Y EVAP TOTAL ASS Y 1 1 DB96 05264B ASS Y EVAP TOTAL ASS Y 1 10 DB67 60030A SPRING SENSOR STS 301 1 1 1 11 DB94 00674A ASS Y RUBBER BEARING ASS Y 1 1 1 12 DB94 00040X ASS Y CROSS FAN ASS Y 1 1 1 13 DB31 10151E MOTOR FAN IN 220 240V 60 50Hz 1 1 1 14 DB94 006...

Page 183: ...VXWHH045E AVXWHH056E AVXWHH071E 21 DB90 01869E ASS Y COVER DISPLAY ASS Y 1 1 1 21 1 DB63 01196A COVER DISPLAY PC 1 1 1 21 2 DB64 01276A INLAY DISPLAY ACRYL 1 1 1 22 DB90 01932A ASS Y COVER CONTROL ASS Y 1 1 1 23 DB60 00204A SPACER EVAP MID PVC 1 1 1 24 DB94 00724A ASS Y SPACER EVAP UP ASS Y PVC 1 1 1 SA SNA SNA SA SNA SNA ...

Page 184: ...MEMO 5 46 Samsung Electronics ...

Page 185: ...arts List Samsung Electronics 5 47 14 7 43 37 29 4 23 18 6 41 40 36 34 32 1 38 19 20 16 24 42 13 15 39 30 26 28 27 3 25 46 33 44 1112 22 21 17 8 31 35 2 5 9 10 45 45 6 45 1 45 2 45 8 45 7 45 3 45 4 45 5 5 1 12 Ceiling type ...

Page 186: ...UTLET ABS 1 1 18 DB31 00158A BLADE V ABS 12 12 19 DB31 00159A BLADE CONNECTOR V ABS 2 2 20 DB31 00164A BLADE CONNECTOR H ABS 2 2 21 DB31 00157A BLADE H ABS 1 1 22 DB31 10153D SWING MOTOR IN ASS Y 1 1 23 DB61 01352A BRACKET DRAIN SGCC M 1 1 24 DB67 00258A DRAIN SUB LF SGCC M 1 1 25 DB67 00259A DRAIN SUB RH ABS 1 1 26 DB75 00247A EVAPORATOR ASS Y 1 1 27 DB96 02651A ASS Y COLLECTOR ASS Y 1 DB96 02651...

Page 187: ...ER CONTROL ABS UL94 V0 1 1 45 DB93 01762F ASS Y CONTROL IN ASS Y 1 DB93 01762E ASS Y CONTROL IN ASS Y 1 45 1 DB61 01154A BASE CONTROL SGCC M 1 1 45 2 DB61 01220A CASE PCB MAIN ABS UL94 V0 1 1 45 3 DB93 01713A CEILING EU PCB ASS Y PCB 1 1 45 4 DB65 00105D TERMINAL BLOCK 6P DAF S6P 1 1 45 5 DB65 00105C TERMINAL BLOCK 6P DAF S6P 1 1 45 6 DB26 10065B TRANS POWER ASS Y 1 1 45 7 2301 001368 CAPACITOR 5u...

Page 188: ...MEMO 5 50 Samsung Electronics ...

Page 189: ...Samsung Electronics 5 51 17 16 9 26 25 18 13 30 14 27 13 1 13 2 19 4 24 29 23 20 31 2 3 5 11 15 6 22 33 21 12 32 1 7 8 28 10 20 1 20 2 5 2 Outdoor Unit 5 2 1 4 5 6HP ...

Page 190: ...7 DB62 03381A INSULATION FELT POLYESTER 18 DB32 00137A THERMISTOR OUT 20 C 100 C 220V 103AT 19 DB32 00139A THERMISTOR DISCHARGE 200Kohm 20 150 20 DB93 03836B ASS Y CONTROL OUT ASS Y DB93 03836A ASS Y CONTROL OUT ASS Y 20 1 DB61 40291C WIRE HOLDER PP 20 2 DB61 02368A FUSE HOLDER ASS Y 21 DB90 01539A ASS Y BRACKET MOTOR ASS Y 22 DB90 01589B ASS Y CABINET BACK RH ASS Y 23 DB93 03828A ASS Y MAIN PCB A...

Page 191: ...Y VALVE EXPANSION ASS Y 16 DB62 03382A INSULATION FELT POLYESTER 1 17 DB62 03381A INSULATION FELT POLYESTER 1 18 DB32 00137A THERMISTOR OUT 20 C 100 C 220V 103AT 1 19 DB32 00139A THERMISTOR DISCHARGE 200Kohm 20 150 1 20 DB93 03836C ASS Y CONTROL OUT ASS Y 1 20 1 DB61 40291C WIRE HOLDER PP 2 20 2 DB61 02368A FUSE HOLDER ASS Y 1 21 DB90 01539A ASS Y BRACKET MOTOR ASS Y 1 22 DB90 01589B ASS Y CABINET...

Page 192: ...MEMO 5 54 Samsung Electronics ...

Page 193: ...Samsung Electronics Exploded Views and Parts List 5 55 28 19 9 12 5 43 4 42 18 27 33 40 45 37 36 32 34 29 31 30 39 23 35 46 41 24 42 13 14 15 17 16 21 22 26 20 3 2 1 6 8 7 25 44 10 5 2 2 8 10HP ...

Page 194: ...Samsung Electronics Exploded Views and Parts List 5 56 48 1 48 2 48 3 48 12 48 5 47 5 48 7 48 4 48 8 48 13 47 4 47 2 48 10 48 6 47 3 47 1 48 9 48 11 8 10HP cont ...

Page 195: ...9A ASS Y CABI SIDE RH ASS Y 1 SNA 19 DB90 02128A ASS Y CABI SIDE LF ASS Y 1 SNA 20 DB90 02130A ASS Y CABI BACK UP ASS Y 1 SNA 21 DB90 02141A ASS Y BASE COMP ASS Y 1 SNA 22 DB61 02600A ASS Y LEG BASE SECC P 970x150 T2 0 2 SNA 23 DB61 02258A BRACKET SERVICE VALVE SECC P 350x350 T2 0 1 SNA 24 DB74 00035A SUB BKT SERVICE VALVE ASS Y 1 SNA 25 DB90 02147A ASS Y FRONT BEAM LOW ASS Y 1 SNA 26 DB90 02317A ...

Page 196: ...DB63 01361B COVER CONTROL IN ABS 5V 1 SA 47 5 DB63 01361C COVER CONTROL IN ABS 5V 1 SA 48 DB93 03736C ASS Y CONTROL BOX ASS Y 1 SNA 48 1 DB90 02269A ASS Y CABI CONTROL BOX ASS Y 1 SNA 48 2 DB93 03805A ASS Y CONTROL IN ASS Y 1 SNA 48 3 DB93 02756C MAIN PCB ASS Y 1 SA 48 4 DB93 02819A POWER PCB ASS Y 1 SA 48 5 DB93 03531A CT PCB 1 COMP1 ASS Y 1 SA 48 6 DB93 03531B CT PCB 2 COMP2 ASS Y 1 SA 48 7 DB65...

Page 197: ...Samsung Electronics Exploded Views and Parts List 5 59 1 2 3 4 5 44 26 20 42 18 27 37 31 34 32 43 12 8 6 40 38 35 41 36 29 30 39 23 24 46 45 33 11 19 28 7 9 25 21 10 22 13 14 15 16 17 5 2 3 12 14HP ...

Page 198: ...Samsung Electronics Exploded Views and Parts List 5 60 48 1 48 2 48 3 48 13 48 11 47 5 48 8 48 4 48 9 48 14 47 4 47 2 48 7 47 3 47 1 48 10 48 12 48 5 48 6 12 14HP cont ...

Page 199: ... ASS Y 1 SNA 19 DB90 02128A ASS Y CABI SIDE LF ASS Y 1 SNA 20 DB90 02140A ASS Y CABI BACK UP ASS Y 1 SNA 21 DB90 02142A ASS Y BASE COMP ASS Y 1 SNA 22 DB61 02601A ASS Y LEG BASE SECC P 970x150 T2 0 2 SNA 23 DB61 02258A BRACKET SERVICE VALVE SECC P 350x350 T2 0 1 SNA 24 DB74 00035A SUB BKT SERVICE VALVE ASS Y 1 SNA 25 DB90 02148A ASS Y FRONT BEAM LOW ASS Y 1 SNA 26 DB90 02320A ASS Y GUARD COND BACK...

Page 200: ...ABS 5V 1 SA 47 5 DB63 01361C COVER CONTROL IN ABS 5V 1 SA 48 DB93 03736G ASS Y CONTROL BOX ASS Y 1 SA 48 1 DB90 02269A ASS Y CABI CONTROL BOX ASS Y 1 SNA 48 2 DB93 03805A ASS Y CONTROL IN ASS Y 1 SNA 48 3 DB93 02756G MAIN PCB ASS Y 1 SNA 48 4 DB93 02819A POWER PCB ASS Y 1 SA 48 5 DB93 03531A CT PCB 1 COMP1 ASS Y 1 SA 48 6 DB93 03531B CT PCB 2 COMP2 ASS Y 1 SA 48 7 DB93 03531C CT PCB 3 COMP3 ASS Y ...

Page 201: ...C CER CHIP 10nF 10 50V X7R 1608 1 SNA C303 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C304 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C305 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C306 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257...

Page 202: ... BOX 10P 1R 2mm STRAIGHT SN BLK 1 SNA CN31 3711 000177 HEADER BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN RED 1 SNA CN32 3711 000178 HEADER BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN WHT 1 SNA CN33 3711 000176 HEADER BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN BLU 1 SNA CN41 3711 004379 HEADER BOARD TO CABLE BOX 4P 1R 2mm STRAIGHT SN NTR 1 SNA CN42 3711 003942 HEADER BOARD TO CABLE BOX 2P 1...

Page 203: ... TP 1 SNA D917 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D918 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D919 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D920 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D921 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP ...

Page 204: ...SNA Q603 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q901 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q902 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q904 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q905 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q906 0504 000001 TR DIGITAL DTA1...

Page 205: ... 8Kohm 1 1 8W TP 2012 1 SNA R404 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R405 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R406 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R440 2007 001071 R CHIP 6 8Kohm 5 1 8W TP 2012 1 SNA R441 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R443 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R502 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R503 2007...

Page 206: ... JT1916 09 310V FERRITE EI1916 130KHz 1 SNA 1 65mH SHIELD SW01 3406 001098 SWITCH ROTARY 240V AC 25A 6P 10C L14mm 1 SNA SW02 3406 001098 SWITCH ROTARY 240V AC 25A 6P 10C L14mm 1 SNA SW03 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SNA 50mOhm Max BULK 10mmx10mm straight SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SNA 50mOhm Max BULK 10mmx10mm straight ...

Page 207: ...0 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 100nF ...

Page 208: ...3711 000879 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN45 3711 003407 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN RED 1 SNA CN46 3711 003407 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN RED 1 SNA CN51 3711 000794 HEADER BOARD TO CABLE BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN52 3711 000024 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN WHT 1 SNA CN60 3711 003844 H...

Page 209: ...P 180 390 1 SNA Q202 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q441 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q442 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q601 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q602 0501 002296 TR SMALL SIGNAL MMST2907A PNP 200mW SMT3 TP 100 300 1 SNA Q603 ...

Page 210: ... 24Kohm 1 1 8W TP 2012 1 SNA R416 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R440 2007 001071 R CHIP 6 8Kohm 5 1 8W TP 2012 1 SNA R441 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R443 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R444 2007 001071 R CHIP 6 8Kohm 5 1 8W TP 2012 1 SNA R445 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R447 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R509 2007...

Page 211: ...P 10Kohm 5 1 8W TP 2012 1 SNA R919 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA RY01 3501 001248 RELAY MINIATURE 12V 11 7mA DPDT 4mS 4mS 1 SNA RY71 3501 001264 RELAY POWER 12VDC 200mW 5000mA 1FormA 10mS 10mS 1 SNA RY72 3501 001264 RELAY POWER 12VDC 200mW 5000mA 1FormA 10mS 10mS 1 SNA SCREW 6002 000630 SCREW TAPPING PH 2S M3 L8 ZPC YEL SWRCH18A 1 SNA SS71 3502 000115 SSR 12Vdc 2A 1mS 1mS 1 SNA SS...

Page 212: ...000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D916 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D917 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D918 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D919 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D920 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D921 0401 0001...

Page 213: ...0 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 100nF ...

Page 214: ...1R 2 5mm STRAIGHT SN WHT 1 SNA CN43 3711 000798 CONNECTOR HEADER BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN51 3711 000794 HEADER BOARD TO CABLE BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN60 3711 000577 HEADER BOARD TO CABLE BOX 10P 1R 2 5mm STRAIGHT SN WHT 1 SNA CN62 3711 001001 CONNECTOR HEADER BOX 5P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SN...

Page 215: ...RLS4148 75V 150mA LL 34 TP 1 SNA D925 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D926 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D927 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA F701 3602 001012 FUSE BLOCK 500V 100m 1 SNA F701_1 3601 000263 FUSE CARTRIDGE 250V 3 15A TIME LAG GLASS 5x20mm 1 SNA F702 3601 001308 FUSE 250V 1 6A TIME LAG PLASTIC 8 4...

Page 216: ...PNP 200mW 10K 10K SOT 23 TP 1 SNA Q907 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q908 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q909 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R10 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R11 2007 000023 R CHIP 120o...

Page 217: ...012 1 SNA R605 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R606 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R607 2007 000931 R CHIP 470ohm 5 1 8W TP 2012 1 SNA R608 2007 000931 R CHIP 470ohm 5 1 8W TP 2012 1 SNA R609 2007 000030 R CHIP 560ohm 5 1 8W TP 2012 1 SNA R610 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R803 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R804 2007 000300 R CHIP 10...

Page 218: ... 10mmx10mm straight SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SNA 50mOhm Max BULK 10mmx10mm straight SW05 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW07 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA X301 2802 001179 RESONATOR CERAMIC ...

Page 219: ...1WALL 2P 1R 3 96mm STRAIGHT SN WHT 1 SNA CN33 3711 000176 CONNECTOR HEADER 1WALL 2P 1R 3 96mm STRAIGHT SN BLU 1 SNA CN41 3711 000940 CONNECTOR HEADER BOX 4P 1R 2 5mm STRAIGHT SN WHT 1 SNA CN42 3711 000015 CONNECTOR HEADER BOX 2P 1R 2 5mm STRAIGHT SN WHT 1 SNA CN43 3711 000798 CONNECTOR HEADER BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN51 3711 000794 CONNECTOR HEADER BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN60...

Page 220: ...PROM 93LC56 128x16 SOP 8P 5x4mm 2 5 6 0V 1 SNA 40to 85C LED11 0601 001373 LED ROUND RED 3mm 630nm 1 SNA LED12 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm 1 SNA LED13 0601 001377 LED ROUND YEL 3mm 585nm 3 8x5 3mm 1 SNA NTC1 1404 001274 THERMISTOR NTC 22OHM 1 4A 3100K 9 5MW C 7 0 1 SNA PC01 0604 001038 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC02 0604 001003 PHOTO COUPLER TR 50 150 200mW DIP...

Page 221: ...Y70 RY71 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 2 SNA SCREW 6002 000630 SCREW TAPPING PH 2S M3 L8 ZPC YEL SWRCH18A 1 SNA SS71 3502 001026 SSR DC 12V 12V 3A 1mS 1 SNA ST11 DB26 00015A TRANS SWITCHING JT1916 09 310V FERRITE EI1916 1 SNA 130KHz 1 65mH SHIELD SW01 SW02 3406 001098 SWITCH DIGITAL 240V AC 25A 6P 10C L14mm 2 SNA SW03 SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTAR...

Page 222: ...20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C401 2203 000192 C CER CHIP 100nF 80...

Page 223: ...TRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN72 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN73 3711 000357 HEADER BOARD TO CABLE 1WALL 5P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN74 3711 003406 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN75 3711 003405 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92m...

Page 224: ...mA LL 34 TP 1 SNA F701 3602 001012 FUSE BLOCK 500V 100m 1 SNA F701_1 3601 000263 FUSE CARTRIDGE 250V 3 15A TIME LAG GLASS 5x20mm 1 SNA F702 3601 001308 FUSE 250V 1 6A TIME LAG PLASTIC 8 4x7 6mm 1 SNA FT71 DB27 00019A COIL CHOKE SSC1905200B Line Filter 20mH 50 30 1 SNA 0 3ohm 2 5A 20x28 mm 13x18 25 HEAT SINK1 DB62 03581A HEAT SINK DPM A6063 1 3 15 15 WHT HEIGHT 25 5 1 SNA IC01 1203 000243 IC POSI F...

Page 225: ...TAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q908 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q909 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R10 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R11 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R12 2007 000023 R CHIP 120ohm 5 1 ...

Page 226: ...HIP 1Kohm 5 1 8W TP 2012 1 SNA R608 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R609 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R610 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R611 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R612 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R613 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R803 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R...

Page 227: ...OTARY DIP DC24V Max 0 4VA 1 SA 50mOhm Max BULK 10mmx10mm straight SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SA 50mOhm Max BULK 10mmx10mm straight SW05 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW07 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm...

Page 228: ...80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C401 2203 000192 C CER CHIP 100nF...

Page 229: ...TRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN72 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN73 3711 000357 HEADER BOARD TO CABLE 1WALL 5P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN74 3711 003406 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN75 3711 003405 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92m...

Page 230: ... LL 34 TP 1 SNA F701 3602 001012 FUSE BLOCK 500V 100m 1 SNA F701_1 3601 000003 FUSE CARTRIDGE 250V 5A FAST ACTING GLASS 5 2x20mm 1 SNA F702 3601 001308 FUSE 250V 1 6A TIME LAG PLASTIC 8 4x7 6mm 1 SNA FT71 DB27 00019A COIL CHOKE SSC1905200B Line Filter 20mH 50 30 1 SNA 0 3ohm 2 5A 20x28 mm 13x18 25 HEAT SINK1 DB62 03581A HEAT SINK DPM A6063 1 3 15 15 WHT HEIGHT 25 5 1 SNA IC01 1203 000243 IC POSI F...

Page 231: ...TAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q908 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q909 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R10 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R11 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R12 2007 000023 R CHIP 120ohm 5 1 ...

Page 232: ...CHIP 1Kohm 5 1 8W TP 2012 1 SNA R608 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R609 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R610 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R611 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R612 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R613 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R803 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA ...

Page 233: ...ARY DIP DC24V Max 0 4VA 50mOhm Max BULK 10mmx10mm straight 1 SA SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 50mOhm Max BULK 10mmx10mm straight 1 SA SW05 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW07 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm T...

Page 234: ...TOR HEADER BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN51 3711 000794 HEADER BOARD TO CABLE BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN62 3711 001001 CONNECTOR HEADER BOX 5P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN72 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT 1 SNA SN WHT CN74 3711 003406 HEADER BOARD TO CABLE 1WALL 2P...

Page 235: ...90 5 SNA Q603 0501 002296 TR SMALL SIGNAL mmST2907A PNP 200mW SMT3 TP 100 300 1 SNA Q901 902 904 910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 9 SNA R10 11 12 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 3 SNA R201 205 206 207 350 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 11 SNA 441 443 601 603 607 902 R202 610 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 2 SNA R204 302 304 307 2007 0003...

Page 236: ...1 75 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 2 SNA X301 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA X701 702 2301 001220 C FILM LEAD PPF 100nF 10 275V BK 18x6x12 15 2 SNA DB41 00364A PBA LOGIC BOARD miniDVM_slimduct_chi FR 4 T 1 6 1 SA 220 240V 50 60Hz DB62 03085A HEAT SINK A6063 25 15 15 SSEC 1 SNA DB68 02809A LABEL BAR CODE W170 L115 FOR PACKING CASE 1 SNA Location No Code ...

Page 237: ...00nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C401 2203 000192 C CER CHIP ...

Page 238: ...X 2P 1R 2 5mm STRAIGHT SN 1 SNA CN51 3711 000794 HEADER BOARD TO CABLE BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN62 3711 001001 CONNECTOR HEADER BOX 5P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN72 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN74 3711 003406 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm ST...

Page 239: ...A D924 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D925 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D926 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D927 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA F01 3601 000297 FUSE CARTRIDGE 250V 5A TIME LAG GLASS 5 2x20mm 1 SNA F701_1 DB61 00924A HOLDER FUSE FH 51B SSEC 1 SNA F702 3601 001308...

Page 240: ...00mW 10K 10K SOT 23 TP 1 SNA Q907 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q908 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q909 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R10 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R11 2007 000023 R CHIP 120ohm 5 ...

Page 241: ... CHIP 1Kohm 5 1 8W TP 2012 1 SNA R608 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R609 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R610 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R611 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R612 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R613 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R803 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA...

Page 242: ...SLIDE STANDARD 1 SNA SW07 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA VA75 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA X301 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA X701 2301 001220 C FILM LEAD PPF 100nF 10 275V BK 18x6x12 15 1 SNA X702 2301 001220 C FILM LEAD PPF 100nF 10 275V BK 18x6x12 15 1 SNA DB41 ...

Page 243: ...CHIP 100nF 80 20 50V Y5V 2012 1 SNA C306 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C312 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C313 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C321 2203 000...

Page 244: ... 3711 003942 HEADER BOARD TO CABLE BOX 2P 1R 2mm STRAIGHT SN WHT 1 SNA CN43 3711 000178 HEADER BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN WHT 1 SNA CN44 3711 000879 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN45 3711 004349 HEADER BOARD TO CABLE BOX 3P 1R 2mm STRAIGHT SN 1 SNA CN61 3711 004484 HEADER BOARD TO CABLE BOX 5P 1R 2mm STRAIGHT SN NTR 1 SNA CN62 3711 001001 CONNECTOR...

Page 245: ... 3 700V 1 SNA 40TO 150C 560mA ST IC02 1203 000274 IC POSI FIXED REG 7805 TO 220 3P PLASTIC 4 8 5 1 SNA IC03 1203 003334 IC RESET S 801 SOT 23 5P 2 9x1 6mm PLASTIC 1 SNA 3 716 4 284V 256mW 2 5mA TP IC04 DB09 00371C IC MICOM MB90F823 80 P 5 V 24 MHz STM 0490 CS 24 16 1 SNA QFP QFP 14x20 mm 16 40 85 IC05 0506 000175 TR ARRAY 2003 NPN 7 1W SOP 16 ST 1000 1 SNA IC06 0506 000175 TR ARRAY 2003 NPN 7 1W S...

Page 246: ... CHIP 47Kohm 5 1 4W TP 3216 1 SNA R209 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R210 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R211 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R212 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R302 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R303 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R304 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R305 ...

Page 247: ... 1 8W TP 2012 1 SNA R911 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R912 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R913 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R914 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA RY01 3501 001248 RELAY MINIATURE 12V 11 7mA DPDT 4mS 4mS 1 SNA SS71 3502 000115 SSR 12Vdc 2A 1mS 1mS 1 SNA ST11 DB26 00015A TRANS SWITCHING JT1916 09 310V FERRITE EI1916 13...

Page 248: ...CHIP 100nF 80 20 50V Y5V 2012 1 SNA C306 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER...

Page 249: ...R BOARD TO CABLE 1WALL 2P 1R 3 96mm STRAIGHT SN BLU 1 SNA CN41 3711 004379 HEADER BOARD TO CABLE BOX 4P 1R 2mm STRAIGHT SN NTR 1 SNA CN42 3711 003942 HEADER BOARD TO CABLE BOX 2P 1R 2mm STRAIGHT SN WHT 1 SNA CN44 3711 000879 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN60 3711 004484 HEADER BOARD TO CABLE BOX 5P 1R 2mm STRAIGHT SN NTR 1 SNA CN61 3711 002001 HEADER BOARD TO CABLE B...

Page 250: ... 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q311 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q501 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q601 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q602 0501 002296 TR SMALL SIGNAL mmST2907A PNP 200mW SMT3 TP 100 300 1 SNA Q603 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW S...

Page 251: ...SNA R404 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R405 2007 001067 R CHIP 6 8Kohm 1 1 8W TP 2012 1 SNA R406 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R501 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R502 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R503 2007 001071 R CHIP 6 8Kohm 5 1 8W TP 2012 1 SNA R505 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R506 2007 000872 R CHIP 4 7Kohm ...

Page 252: ...71 3502 000115 SSR 12Vdc 2A 1mS 1mS 1 SNA ST11 DB26 00015A TRANS SWITCHING JT1916 09 310V FERRITE EI1916 130KHz 1 SNA 1 65mH SHIELD VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA X501 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8X3X5 5mm 1 SNA XC71 2301 001439 C FILM LEAD PPF 220nF 10 275V BK 18x10x15 8mm 15 1 SNA XC72 2301 001220 C FILM LEAD PPF 100nF 10 275V BK 18x6x12 15 1 SNA ZD11 04...

Page 253: ...IODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D917 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D918 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D919 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D920 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D921 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE...

Page 254: ...0nF 80 20 50V Y5V 2012 1 SNA C307 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C311 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C312 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C313 2203 000257 C CER CHIP 10nF 10 50V X7R 1608 1 SNA C314 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C315 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C316 2203 000192 C CER CHIP 1...

Page 255: ... 1 SNA CN51 3711 000794 HEADER BOARD TO CABLE BOX 2P 1R 2 5mm STRAIGHT SN 1 SNA CN61 3711 001036 HEADER BOARD TO CABLE BOX 6P 1R 2 5mm STRAIGHT SN 1 SNA CN62 3711 001001 CONNECTOR HEADER BOX 5P 1R 2 5mm STRAIGHT SN BLU 1 SNA CN71 3711 003404 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN72 3711 000203 HEADER BOARD TO CABLE 1WALL 2P 3P 1R 7 92mm STRAIGHT SN WHT 1 SNA CN73 3711 00...

Page 256: ...P 1 SNA D926 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D927 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA F701 3602 001012 FUSE BLOCK 500V 100m 1 SNA F701_1 3601 000263 FUSE CARTRIDGE 250V 3 15A TIME LAG GLASS 5x20mm 1 SNA F702 3601 001308 FUSE 250V 1 6A TIME LAG PLASTIC 8 4x7 6mm 1 SNA FT71 DB27 00019A COIL CHOKE SSC1905200B Line Filter 20mH 50 30 0 3ohm 2 5A 20x...

Page 257: ...W 10K 10K SOT 23 TP 1 SNA Q906 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q907 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q908 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q909 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q910 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R10 2007 00002...

Page 258: ...012 1 SNA R604 2007 000931 R CHIP 470ohm 5 1 8W TP 2012 1 SNA R605 2007 000931 R CHIP 470ohm 5 1 8W TP 2012 1 SNA R606 2007 000030 R CHIP 560ohm 5 1 8W TP 2012 1 SNA R607 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R608 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R609 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R610 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R611 2007 000872 R CHIP 4 ...

Page 259: ...06 001098 SWITCH ROTARY 240V AC 25A 6P 10C L14mm 1 SNA SW03 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SNA 50mOhm Max BULK 10mmx10mm straight SW04 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SNA 50mOhm Max BULK 10mmx10mm straight SW05 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW07 3407...

Page 260: ...203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C404 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C409 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C410 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C411 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C412 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C70 2301 001325 C FILM LEAD PPF 330nF 10 275V TP 26x...

Page 261: ... 004182 CONNECTOR HEADER BOX 10P 1R 2mm STRAIGHT SN NTR 1 SNA D101 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D102 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D103 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D104 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D105 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D901 0401 000133 DIODE SWITC...

Page 262: ...1 DB61 00924A HOLDER FUSE FH 51B SSEC 1 SNA FT71 2901 001181 FILTER EMI AC LINE 250V 1A 100000pF 20 5x20 5x32mm BK RADIAL 1 SNA GT 1 3712 001062 CONNECTOR TERMINAL PIN MALE 18 22 2 35mm 1 SNA IC01 1203 000243 IC POSI FIXED REG 7812 TO 220 3P PLASTIC 11 5 12 5V 16W 1 SNA 0TO 125C 1A ST IC02 1203 000274 IC POSI FIXED REG 7805 TO 220 3P PLASTIC 4 8 5 1 SNA IC03 1203 003334 IC RESET S 801 SOT 23 5P 2 ...

Page 263: ...00001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R201 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R202 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R203 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R204 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R205 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R301 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R302 2007 000300 R CHIP 10Koh...

Page 264: ... 3000mA 1FormA 10mS 10mS 1 SA RY79 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SA RY82 3501 001163 RELAY MINIATURE 12VDC 200MW 5000mA 1FormA 10mS 5mS 1 SA RY83 3501 001163 RELAY MINIATURE 12VDC 200MW 5000mA 1FormA 10mS 5mS 1 SA RY84 3501 001163 RELAY MINIATURE 12VDC 200MW 5000mA 1FormA 10mS 5mS 1 SA RY85 3501 001163 RELAY MINIATURE 12VDC 200MW 5000mA 1FormA 10mS 5mS 1 SA RY86...

Page 265: ...5V 2012 1 SNA C403 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C404 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C409 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C410 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C411 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C412 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C70 2301 001325 C FILM LEAD PPF ...

Page 266: ...HT NI WHT 1 SNA CN91 3711 004182 CONNECTOR HEADER BOX 10P 1R 2mm STRAIGHT SN NTR 1 SNA D101 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D102 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D103 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D104 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D105 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA D90...

Page 267: ...01 000297 FUSE CARTRIDGE 250V 5A TIME LAG GLASS 5 2x20mm 1 SNA F701_1 DB61 00924A HOLDER FUSE FH 51B SSEC 1 SNA FT71 2901 001181 FILTER EMI AC LINE 250V 1A 100000pF 20 5x20 5x32mm BK RADIAL 1 SNA GT 1 3712 001062 CONNECTOR TERMINAL PIN MALE 18 22 2 35mm 1 SNA IC01 1203 000243 IC POSI FIXED REG 7812 TO 220 3P PLASTIC 11 5 12 5V 16W 1 SNA 0TO 125C 1A ST IC02 1203 000274 IC POSI FIXED REG 7805 TO 220...

Page 268: ...GITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA Q604 0504 000001 TR DIGITAL DTA114EKA PNP 200mW 10K 10K SOT 23 TP 1 SNA R201 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R202 2007 000686 R CHIP 3 3Kohm 5 1 8W TP 2012 1 SNA R203 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R204 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R205 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R301 2007 000023 R C...

Page 269: ...ELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SA RY79 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SA RY82 3501 001163 RELAY MINIATURE 12Vdc 200mW 5000mA 1FormA 10mS 5mS 1 SA RY83 3501 001163 RELAY MINIATURE 12Vdc 200mW 5000mA 1FormA 10mS 5mS 1 SA RY84 3501 001163 RELAY MINIATURE 12Vdc 200mW 5000mA 1FormA 10mS 5mS 1 SA RY85 3501 001163 RELAY MINIATURE 12Vdc 200mW 5000mA...

Page 270: ...0 20 50V Y5V 2012 1 SNA C403 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C404 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C409 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C410 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C411 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C412 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C503 2203 000192 C CER...

Page 271: ...1R 7 92mm STRAIGHT SN BLU 1 SNA CN81 3711 000316 HEADER BOARD TO CABLE 1WALL 7P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN82 3711 000263 HEADER BOARD TO CABLE 1WALL 3P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN83 3711 000744 HEADER BOARD TO CABLE BOX 1P 1R 8mm STRAIGHT NI WHT 1 SNA CN91 3711 004182 CONNECTOR HEADER BOX 10P 1R 2mm STRAIGHT SN NTR 1 SNA D101 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA ...

Page 272: ...1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 DIS2 DB07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 DS71 DB47 00016A POSISTOR DSA 332mA 2pF MAX 100Mohm ASM 3500 1 SNA F101 3601 000248 FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 SNA F101_1 DB61 00924A HOLDER FUSE FH 51B SSEC 1 SNA F701 3601 000297 FUSE CARTRIDGE 250V 5A TIME LAG ...

Page 273: ... 12V 50mA 160gf 6 1x6 1x5 0mm SPST 1 SNA LED01 0601 001377 LED ROUND YEL 3mm 585nm 3 8x5 3mm 1 SNA LED02 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm 1 SNA LED03 0601 001373 LED ROUND RED 3mm 630nm 1 SNA OPT1 3711 000024 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN WHT 1 SNA Q201 0501 000534 TR SMALL SIGNAL 2SC2412K NPN 200mW SOT 23 TP 180 390 1 SNA Q601 0504 000001 TR DIGITAL DTA114EKA PNP ...

Page 274: ... R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R512 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R601 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R602 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R603 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R604 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R605 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R606 2007 000468 R CHIP 1Kohm 5...

Page 275: ...2 000115 SSR 12Vdc 2A 1mS 1mS 1 SNA SW01 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SA 50mOhm Max BULK 10mmx10mm straight SW02 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW03 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA VA72 1405 000147 VARISTOR 470V 4500A 17x12mm BK 1 SNA VA73 1405 000147 VARISTOR...

Page 276: ...0 20 50V Y5V 2012 1 SNA C403 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C404 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C409 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C410 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C411 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C412 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C503 2203 000192 C CER...

Page 277: ...1R 7 92mm STRAIGHT SN BLU 1 SNA CN81 3711 000316 HEADER BOARD TO CABLE 1WALL 7P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN82 3711 000263 HEADER BOARD TO CABLE 1WALL 3P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN83 3711 000744 HEADER BOARD TO CABLE BOX 1P 1R 8mm STRAIGHT NI WHT 1 SNA CN91 3711 004182 CONNECTOR HEADER BOX 10P 1R 2mm STRAIGHT SN NTR 1 SNA D101 0402 000137 DIODE RECTIFIER 1N4007 1KV 1A DO 41 TP 1 SNA ...

Page 278: ...07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 DIS2 DB07 00054A LED DISPLAY SSD A3202GS A13 LED DISPLAY 2 DIGIT 1 SNA 16 SEGMENT 2 DIGIT 16 6x16x13mm GREEN 50mW 9 DS71 DB47 00016A POSISTOR DSA 332mA 2pF MAX 100Mohm ASM 3500 1 SNA F101 3601 000248 FUSE CARTRIDGE 250V 2A TIME LAG GLASS 5x20mm 1 SNA F101_1 DB61 00924A HOLDER FUSE FH 51B SS...

Page 279: ... 1 SNA K24 3812 001283 WIRE NO SHEATH CU TCWA 300V 52mm TAPING 1 0 6mm 1 SNA K3 3404 001220 SWITCH TACT 12V 50mA 160gf 6 1x6 1x5 0mm SPST 1 SNA K4 3404 001220 SWITCH TACT 12V 50mA 160gf 6 1x6 1x5 0mm SPST 1 SNA LED01 0601 001377 LED ROUND YEL 3mm 585nm 3 8x5 3mm 1 SNA LED02 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm 1 SNA LED03 0601 001373 LED ROUND RED 3mm 630nm 1 SNA OPT1 3711 000024 HEADER B...

Page 280: ...AL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R509 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R510 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R511 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R512 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R601 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R602 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1...

Page 281: ...W 5000mA 1FormA 10mS 5mS 1 SA RY87 3501 001163 RELAY MINIATURE 12Vdc 200mW 5000mA 1FormA 10mS 5mS 1 SA SS71 3502 000115 SSR 12Vdc 2A 1mS 1mS 1 SNA SW01 DB34 00009A SWITCH DIGITAL PT65 103 ROTARY DIP DC24V Max 0 4VA 1 SA 50mOhm Max BULK 10mmx10mm straight SW02 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW03 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA71 1405 000154 VARISTOR 4...

Page 282: ...F 10 50V X7R 2012 1 SNA C321 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C322 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C323 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C324 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C325 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C326 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C334 2203 001562 C CER CH...

Page 283: ...12 1 SNA C506 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C54 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C55 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C56 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C601 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C602 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C603 2203 000192 C CER CHIP 100nF 80 20 5...

Page 284: ...A CN75 3711 002855 HEADER BOARD TO CABLE BOX 2P 1R 7 92mm STRAIGHT SN 1 SNA CN76 3711 006056 HEADER BOARD TO BOARD BOX 2P 1R 7 92mm STRAIGHT SN BLK 1 SNA CN79 3711 005852 HEADER BOARD TO CABLE BOX 2P 1R 5mm STRAIGHT SN WHT 1 SNA CN81 3711 006057 HEADER BOARD TO BOARD BOX 2P 1R 5mm STRAIGHT SN BLK 1 SNA CN82 3711 006049 HEADER BOARD TO BOARD BOX 2P 1R 5mm STRAIGHT SN YEL 1 SNA CN83 3711 000263 HEAD...

Page 285: ... 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D923 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D924 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D925 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D926 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D927 0401 000133 DIODE SWITCHING RLS4148 75V...

Page 286: ...70nm 3 8x5 3mm 1 SNA LED07 0601 000402 LED ROUND YEL 3mm 585nm 1 SNA LED08 0601 001373 LED ROUND RED 3mm 630nm 1 SNA OPT1 3711 000024 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN WHT 1 SNA PC02 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC03 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC04 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC501 0604 001038 PHOTO COUPLER TR 130 26...

Page 287: ...007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R311 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R323 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R324 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R325 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R326 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R334 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R335 2007 000023 R CHIP 120ohm 5 1 8W TP 2...

Page 288: ...00766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R438 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R501 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R502 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R503 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R504 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R505 2003 002114 R METAL OXIDE S 200Kohm 5 2W A...

Page 289: ...00300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA RY71 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY72 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY74 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY75 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY76 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA ...

Page 290: ...F 10 50V X7R 2012 1 SNA C321 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C322 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C323 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C324 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C325 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C326 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C334 2203 001562 C CER CH...

Page 291: ...12 1 SNA C506 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C54 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C55 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C56 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C601 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C602 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C603 2203 000192 C CER CHIP 100nF 80 20 5...

Page 292: ...A CN75 3711 002855 HEADER BOARD TO CABLE BOX 2P 1R 7 92mm STRAIGHT SN 1 SNA CN76 3711 006056 HEADER BOARD TO BOARD BOX 2P 1R 7 92mm STRAIGHT SN BLK 1 SNA CN79 3711 005852 HEADER BOARD TO CABLE BOX 2P 1R 5mm STRAIGHT SN WHT 1 SNA CN81 3711 006057 HEADER BOARD TO BOARD BOX 2P 1R 5mm STRAIGHT SN BLK 1 SNA CN82 3711 006049 HEADER BOARD TO BOARD BOX 2P 1R 5mm STRAIGHT SN YEL 1 SNA CN83 3711 000263 HEAD...

Page 293: ... 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D923 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D924 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D925 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D926 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D927 0401 000133 DIODE SWITCHING RLS4148 75V...

Page 294: ...70nm 3 8x5 3mm 1 SNA LED07 0601 000402 LED ROUND YEL 3mm 585nm 1 SNA LED08 0601 001373 LED ROUND RED 3mm 630nm 1 SNA OPT1 3711 000024 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN WHT 1 SNA PC02 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC03 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC04 0604 001173 PHOTO COUPLER TTL 210mW SO 8 TP 1 SNA PC501 0604 001038 PHOTO COUPLER TR 130 26...

Page 295: ...000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R323 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R324 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R325 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R326 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R334 2007 000872 R CHIP 4 7Kohm 5 1 8W TP 2012 1 SNA R335 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 1 SNA R336 2007 000023 R CHIP 120ohm 5 1 8W TP 2012 ...

Page 296: ...000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R501 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R502 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R503 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R504 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R505 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R506 2003 002114 R METAL OXIDE S ...

Page 297: ...W TP 2012 1 SNA RY71 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY72 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY74 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY75 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY76 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY77 3501...

Page 298: ...F 10 50V X7R 2012 1 SNA C321 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C322 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C323 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C324 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C325 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C326 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C334 2203 001562 C CER CH...

Page 299: ...12 1 SNA C506 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C54 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C55 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C56 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C601 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C602 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C603 2203 000192 C CER CHIP 100nF 80 20 5...

Page 300: ... TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN74 3711 003407 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN RED 1 SNA CN75 3711 002855 HEADER BOARD TO CABLE BOX 2P 1R 7 92mm STRAIGHT SN 1 SNA CN76 3711 006056 HEADER BOARD TO BOARD BOX 2P 1R 7 92mm STRAIGHT SN BLK 1 SNA CN77 3711 006052 HEADER BOARD TO BOARD BOX 2P 1R 7 92mm STRAIGHT SN RED 1 SNA CN79 3711 005852 HEADER BOARD TO CABLE ...

Page 301: ...ITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D919 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D920 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D921 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D923 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D924 0401 000133 DIODE SWITCH...

Page 302: ... 50mA 160gf 6x6mm SPST 1 SNA K3 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA K4 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA LED06 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm 1 SNA LED07 0601 000402 LED ROUND YEL 3mm 585nm 1 SNA LED08 0601 001373 LED ROUND RED 3mm 630nm 1 SNA OPT1 3711 000024 HEADER BOARD TO CABLE BOX 3P 1R 2 5mm STRAIGHT SN WHT 1 SNA PC02 0604 001173 PHOTO...

Page 303: ...W TP 2012 1 SNA R305 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R309 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R310 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R311 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R323 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R324 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R325 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R326 2007 000300 R CHI...

Page 304: ...000613 R CHIP 24Kohm 1 1 8W TP 2012 1 SNA R436 2007 000613 R CHIP 24Kohm 1 1 8W TP 2012 1 SNA R437 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R438 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R501 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R502 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R503 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R504 20...

Page 305: ...Kohm 5 1 8W TP 2012 1 SNA R903 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R904 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA RY71 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY72 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY73 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY74 3501 001154 RELAY MINIATURE 12Vdc 200mW ...

Page 306: ... STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA74 1405 000147 VARISTOR 470V 4500A 17x12mm BK 1 SNA X501 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA X502 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA Location No Code No Description Q TY SA SNA Remark Specification ...

Page 307: ...F 10 50V X7R 2012 1 SNA C321 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C322 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C323 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C324 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C325 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C326 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C334 2203 001562 C CER CH...

Page 308: ... CHIP 10nF 80 20 50V Y5V 2012 1 SNA C506 2203 001562 C CER CHIP 10nF 80 20 50V Y5V 2012 1 SNA C54 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C55 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C56 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C601 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C602 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C603 2203 0001...

Page 309: ...LE 1WALL 7P 1R 7 92mm STRAIGHT SN BLU 1 SNA CN73 3711 003406 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN YEL 1 SNA CN74 3711 003407 HEADER BOARD TO CABLE 1WALL 2P 1R 7 92mm STRAIGHT SN RED 1 SNA CN75 3711 002855 HEADER BOARD TO CABLE BOX 2P 1R 7 92mm STRAIGHT SN 1 SNA CN76 3711 006056 HEADER BOARD TO BOARD BOX 2P 1R 7 92mm STRAIGHT SN BLK 1 SNA CN77 3711 006052 HEADER BOARD TO BOARD BOX 2...

Page 310: ...00133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D918 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D919 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D920 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D921 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D922 0401 000133 DIODE SWITCHING RLS4148 75V 150mA LL 34 TP 1 SNA D923 0401 00013...

Page 311: ...5x4mm 2 5 6 0V 40to 85C 1 SNA K1 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA K2 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA K3 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA K4 3404 000165 SWITCH TACT 12V 50mA 160gf 6x6mm SPST 1 SNA LED06 0601 001375 LED ROUND GRN 3mm 570nm 3 8x5 3mm 1 SNA LED07 0601 000402 LED ROUND YEL 3mm 585nm 1 SNA LED08 0601 001373 LED ROUND ...

Page 312: ...468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R303 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R304 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R305 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R309 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R310 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R311 2007 000468 R CHIP 1Kohm 5 1 8W TP 2012 1 SNA R323 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R3...

Page 313: ...000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R434 2007 000457 R CHIP 18Kohm 5 1 8W TP 2012 1 SNA R435 2007 000613 R CHIP 24Kohm 1 1 8W TP 2012 1 SNA R436 2007 000613 R CHIP 24Kohm 1 1 8W TP 2012 1 SNA R437 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R438 2007 000766 R CHIP 330ohm 5 1 8W TP 2012 1 SNA R501 2003 002114 R METAL OXIDE S 200Kohm 5 2W AA TP 4x12mm 1 SNA R502 2003 002114 R METAL OXIDE S ...

Page 314: ...CHIP 47Kohm 5 1 8W TP 2012 1 SNA R901 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R902 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R903 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA R904 2007 000300 R CHIP 10Kohm 5 1 8W TP 2012 1 SNA RY71 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY72 3501 001154 RELAY MINIATURE 12Vdc 200mW 3000mA 1FormA 10mS 10mS 1 SNA RY73 3501...

Page 315: ... STANDARD 1 SNA SW05 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA SW06 3407 000121 SWITCH DIP 24V 300mA SLIDE STANDARD 1 SNA VA74 1405 000147 VARISTOR 470V 4500A 17x12mm BK 1 SNA X501 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA X502 2802 001179 RESONATOR CERAMIC 4MHz 0 5 BK 8x3x5 5mm 1 SNA Location No Code No Description Q TY SA SNA Remark Specification ...

Page 316: ...0192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C719 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C720 2306 000123 C FILM LEAD PPF 100nF 5 630V BK 26x16 5x8 5 2 1 SNA C722 2203 000192 C CER CHIP 100nF 80 20 50V Y5V 2012 1 SNA C723 2201 000007 C CERAMIC DISC 4 7nF 20 400V Y5P BK 16x7mm 7 5 1 SNA CD701 0406 001086 DIODE TVS ST02D 200 185 200 215V 200W DO 214 1 SNA CD702 0406 001086 DIODE TVS...

Page 317: ...BA 12 0mH 25 C 85 C 1 SNA 300mΩ MAX 12mH 37 5x30mm B PC002 0604 000117 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC003 0604 000117 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC004 0604 000117 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC005 0604 000117 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC006 0604 000117 PHOTO COUPLER TR 130 260 200mW DIP 4 ST 1 SNA PC007 0604 000117 PHOTO COU...

Page 318: ...A SCREW 6002 000630 SCREW TAPPING PH 2S M3 L8 ZPC YEL SWRCH18A 2 SNA T701 DB26 00058A TRANS SWITCHING PLUS2 EI1916 DVM PLUS2 PJT 220V 15V Ei1916 50Hz 1 SNA 1 5mH S W TRANS VA71 1405 000154 VARISTOR 460Vdc 2500A 17 5x7 5mm TP 1 SNA VA72 1405 000147 VARISTOR 470V 4500A 17x12mm BK 1 SNA VA73 1405 000147 VARISTOR 470V 4500A 17x12mm BK 1 SNA X701 2301 001285 C FILM LEAD PPF 680nF 10 275V BK 31x11x21mm ...

Page 319: ...Y DIODE SCHOTTKY 1 SNA D602 DB98 16595A ASSY DIODE SCHOTTKY 1 SNA PCB DB41 00369A PBA LOGIC BOARD DVM PLUS2 CT FR 1 T 1 6 1 SA R601 2001 000032 R CARBON 180ohm 5 1 4W AA TP 2 4x6 4mm 1 SNA R602 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R603 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R604 2007 000297 R CHIP 10Kohm 1 1 8W TP 2012 1 SNA R605 2007 000297 R CHIP 10Kohm 1 1 8W TP 2012 1 SNA Locat...

Page 320: ...D601 DB98 16595A ASSY DIODE SCHOTTKY 1 SNA D602 DB98 16595A ASSY DIODE SCHOTTKY 1 SNA PCB DB41 00369A PBA LOGIC BOARD DVM PLUS2 CT FR 1 T 1 6 1 SA R601 2001 000032 R CARBON 180ohm 5 1 4W AA TP 2 4x6 4mm 1 SNA R602 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R603 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R604 2007 000297 R CHIP 10Kohm 1 1 8W TP 2012 1 SNA R605 2007 000297 R CHIP 10Kohm 1 1 8W...

Page 321: ...D601 DB98 16595A ASSY DIODE SCHOTTKY 1 SNA D602 DB98 16595A ASSY DIODE SCHOTTKY 1 SNA PCB DB41 00369A PBA LOGIC BOARD DVM PLUS2 CT FR 1 T 1 6 1 SA R601 2001 000032 R CARBON 180ohm 5 1 4W AA TP 2 4x6 4mm 1 SNA R602 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R603 2007 000781 R CHIP 33ohm 5 1 8W TP 2012 1 SNA R604 2007 000297 R CHIP 10Kohm 1 1 8W TP 2012 1 SNA R605 2007 000297 R CHIP 10Kohm 1 1 8W...

Page 322: ...7 1 Samsung Electronics This Document can not be used without Samsung s authorization 7 Wiring Diagram 7 1 Indoor Unit 7 1 1 1 way cassette type ...

Page 323: ...Wiring Diagram Samsung Electronics 7 2 This Document can not be used without Samsung s authorization 7 1 2 2 way cassette type ...

Page 324: ...Wiring Diagram 7 3 Samsung Electronics This Document can not be used without Samsung s authorization 7 1 3 4 way cassette type ...

Page 325: ...Wiring Diagram Samsung Electronics 7 4 This Document can not be used without Samsung s authorization 7 1 4 Mini 4 way cassette type ...

Page 326: ...7 5 Samsung Electronics Wiring Diagram This Document can not be used without Samsung s authorization 7 1 5 Duct type Low silhouette Built in ...

Page 327: ...Wiring Diagram Samsung Electronics 7 6 This Document can not be used without Samsung s authorization 7 1 6 Duct type High Low pressure ...

Page 328: ...Wiring Diagram 7 7 Samsung Electronics This Document can not be used without Samsung s authorization 7 1 7 Duct type Slim1 Slim2 ...

Page 329: ...Wiring Diagram Samsung Electronics 7 8 This Document can not be used without Samsung s authorization 7 1 8 Duct type Slim3 ...

Page 330: ...Wiring Diagram 7 9 Samsung Electronics This Document can not be used without Samsung s authorization 7 1 9 Wall mounted type Premium ...

Page 331: ...Wiring Diagram Samsung Electronics 7 10 This Document can not be used without Samsung s authorization 7 1 10 Wall mounted type Prestige ...

Page 332: ...Wiring Diagram 7 11 Samsung Electronics This Document can not be used without Samsung s authorization 7 1 11 Ceiling type ...

Page 333: ...Samsung Electronics 7 12 This Document can not be used without Samsung s authorization 7 2 Outdoor Unit 7 2 1 1 phase 4HP ...

Page 334: ...Wiring Diagram 7 13 Samsung Electronics This Document can not be used without Samsung s authorization 7 2 2 1 phase 5HP ...

Page 335: ...Wiring Diagram Samsung Electronics 7 14 This Document can not be used without Samsung s authorization 7 2 3 3 phase 5 6HP ...

Page 336: ...Wiring Diagram 7 15 Samsung Electronics This Document can not be used without Samsung s authorization 7 2 4 8 10HP ...

Page 337: ...Wiring Diagram Samsung Electronics 7 16 This Document can not be used without Samsung s authorization 7 2 5 12 14HP ...

Page 338: ...8 1 Samsung Electronics This Document can not be used without Samsung s authorization 8 Schematic Diagram 8 1 Indoor Unit 8 1 1 1 way cassette type ...

Page 339: ...Wiring Diagram Samsung Electronics 8 2 This Document can not be used without Samsung s authorization 8 1 2 2 way cassette type ...

Page 340: ...Wiring Diagram 8 3 Samsung Electronics 8 1 3 4 way cassette type This Document can not be used without Samsung s authorization ...

Page 341: ...Wiring Diagram Samsung Electronics 8 4 8 1 4 Mini 4 way cassette type This Document can not be used without Samsung s authorization ...

Page 342: ...Wiring Diagram 8 5 Samsung Electronics 8 1 5 Duct type This Document can not be used without Samsung s authorization ...

Page 343: ...Wiring Diagram Samsung Electronics 8 6 8 1 6 Wall mounted type This Document can not be used without Samsung s authorization ...

Page 344: ...Wiring Diagram 8 7 Samsung Electronics 8 1 7 Ceiling type This Document can not be used without Samsung s authorization ...

Page 345: ...Samsung Electronics 8 8 This Document can not be used without Samsung s authorization 8 2 Outdoor Unit mini DVM Series ...

Page 346: ...8 9 Samsung Electronics This Document can not be used without Samsung s authorization 8 3 Outdoor Unit DVM Plus2 Series 8 3 1 MAIN PCB 1 ...

Page 347: ...Wiring Diagram Samsung Electronics 8 10 8 3 2 MAIN PCB 2 This Document can not be used without Samsung s authorization ...

Page 348: ...Wiring Diagram 8 11 Samsung Electronics 8 3 3 POWER PCB This Document can not be used without Samsung s authorization ...

Page 349: ...Samsung Electronics 9 1 9 Refrigerant circuit diagram 9 1 Cooling Operation RVXMHF High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Temperature Low Pressure Gas ...

Page 350: ...Oil Seperator Hot Gas Valve Oil Valve 2 Accumulator Suction Sensor Low Pressure Sensor Double tube sensor Oil Valve 1 Filter Thermo OFF EEV Filter OFF Evap Out Sensor Cond Out Sensor Evap Out Sensor Fixed1 Temperature Sensor Pressure Sensor or Switch Service Valve Check Valve High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Temperature Low Pressure Gas Solenoid Valve El...

Page 351: ...Valve Pressure Switch Oil Seperator Hot Gas Valve Oil Valve 2 Oil Valve 3 Accumulator Suction Sensor Low Pressure Sensor Double tube sensor Oil Valve 1 Filter Thermo OFF EEV Filter OFF Evap Out Sensor Cond Out Sensor Evap Out Sensor Fixed1 Fixed2 Temperature Sensor Pressure Sensor or Switch Service Valve Check Valve High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Tempe...

Page 352: ...9 4 Samsung Electronics RVXMHF High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Temperature Low Pressure Gas 9 2 Heating Operation ...

Page 353: ...ve Pressure Switch Oil Seperator Hot Gas Valve Oil Valve 2 Accumulator Suction Sensor Low Pressure Sensor Double tube sensor Oil Valve 1 Filter Thermo OFF EEV Filter OFF Evap Out Sensor Cond Out Sensor Evap Out Sensor Fixed1 Temperature Sensor Pressure Sensor or Switch Service Valve Check Valve High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Temperature Low Pressure Ga...

Page 354: ...Valve Pressure Switch Oil Seperator Hot Gas Valve Oil Valve 2 Oil Valve 3 Accumulator Suction Sensor Low Pressure Sensor Double tube sensor Oil Valve 1 Filter Thermo OFF EEV Filter OFF Evap Out Sensor Cond Out Sensor Evap Out Sensor Fixed1 Fixed2 Temperature Sensor Pressure Sensor or Switch Service Valve Check Valve High Temperature High Pressure Gas High Temperature High Pressure Liquid Low Tempe...

Page 355: ...gh Pressure Switch If the high pressure is more than the setting value stop the system to protect 18 Main EEV Sub EEV This is the expansion side being used during heating operation control the refrigerant flux 19 Liquid EEV Use to prevent the compressor overheating and control the degree of the overcooling during cooling operation 10 Hot Gas Valve Use to prevent sudden dropping to the low pressure...

Page 356: ...o protect the compressor by measuring the compressor oil temperature 20 Oil Valve Sensor Distinguish whether there is equal oil operation between outdoor units by detecting oil movement between outdoor units 21 4 way Valve Use for convert the cooling and heating 22 Sub cooler Do the heat exchange of the overcooling liquid of the condenser outlet with the refrigerant of the compressor inhalation si...

Page 357: ... CN73 WHITE FAN MOTOR CN71 BLUE AC POWER CN83 RED EXTERNAL CONTROL CN44 BLUE HALL IC CN42 WHITE EVA OUT SENSOR CN41 WHITE ROOM EVA IN SENSOR CN51 BLACK FLOAT S W No CN COLOR FUNCTION CN32 WHITE REMOCON DC12V 1 CN60 WHITE LOUVER 2 CN10 BLACK MICOM DOWNLOAD 3 CN62 BLUE EEV 4 CN91 WHITE DISPLAY 5 CN81 RED CHECK 6 CN31 RED COMM1 OUTDOOR 7 CN33 BLUE COMM2 REMOCON A B ...

Page 358: ...ote control not use use K2 Centralized control not use use K3 RPM up N A N A K4 Option drain pump N A N A K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B ...

Page 359: ...AT S W CN60 WHITE LOUVER CN41 WHITE PIPE IN ROOM SENSOR 1 CN42 WHITE EVA OUT SENSOR 2 CN62 BLUE EEV 3 CN32 WHITE REMOCON DC12V No CN COLOR FUNCTION 4 CN10 BLACK MICOM DOWNLOAD 5 CN11 RED TRANS OUT 6 CN72 WHITE TRANS IN 7 CN45 RED FAN CAPACITOR 8 CN46 RED FAN CAPACITOR 9 CN73 WHITE FAN MOTOR 1 0 CN78 BLUE FAN MOTOR 2 CN71 BLUE AC POWER CN74 YELLOW DRAIN PUMP CN81 RED CHECK CN83 RED EXTERNAL CONTROL...

Page 360: ...N A N A K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 361: ...OR CN76 YELLOW EXTERNAL OPTION PCB CONNECTER CN62 BLUE EEV CN60 WHITE LOUVER CN10 BLACK MICOM DOWNLOAD CN31 RED COMM1 OUTDOOR CN33 BLUE COMM2 REMOCON No CN COLOR FUNCTION CN81 RED CHECK 1 CN11 RED TRANS OUT 2 CN91 WHITE DISPLAY 3 CN71 BLUE AC POWER 4 CN83 RED EXTERNAL CONTROL 5 CN32 WHITE REMOCON DC12V 6 CN72 WHITE TRANS IN 7 CN73 WHITE FAN MOTOR 8 CN74 YELLOW DRAIN PUMP A B ...

Page 362: ... N A N A K5 Heating thermo off 5 C 2 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 363: ...NTROL OUT CN81 RED ERROR COMPRESSOR STATE CN83 RED EXTERNAL CONTROL IN ON OFF CONTROL SIGNAL CN51 BLACK FLOATING SWITCH No CN COLOR FUNCTION 1 CN41 WHITE ROOM EVA IN TEMP SENSOR 2 CN42 WHITE EVA OUT TEMP SENSOR 3 CN43 YELLOW HEATER DISCHARGE TEMP SENSOR 4 CN44 BLUE RPM FEEDBACK 5 CN33 BLUE COMMUNICATION2 WIRED REMOCON_F3 F4 6 CN31 RED COMMUNICATION1 OUTDOOR_F1 F2 7 CN32 WHITE DC12V OUT WIRED REMOC...

Page 364: ... N A N A K5 Heating thermo off 5 C 2 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 365: ...CON DC12V CN83 RED EXTERNAL CONTROL CN62 BLUE EEV CN91 WHITE DISPLAY CN10 BLACK MICOM DOWNLOAD CN31 RED COMM1 OUTDOOR CN33 BLUE COMM2 REMOCON No CN COLOR FUNCTION 1 CN11 RED TRANS OUT 2 CN71 BLUE AC POWER 3 CN72 WHITE TRANS IN 4 CN81 RED CHECK 5 CN76 YELLOW EXTERNAL OPTION PCB CONNECTER 6 CN77 RED HOT COIL 7 CN74 YELLOW DRAIN PUMP 8 CN75 BLACK VENTILATOR 9 CN73 WHITE FAN MOTOR A B 7 6 3 2 1 9 8 ...

Page 366: ...t use use K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil not use use K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 367: ... DC12V CN83 RED EXTERNAL CONTROL CN62 BLUE EEV CN91 WHITE DISPLAY CN10 BLACK MICOM DOWNLOAD CN31 RED COMM1 OUTDOOR CN33 BLUE COMM2 REMOCON No CN COLOR FUNCTION 1 CN11 RED TRANS OUT 2 CN71 BLUE AC POWER 3 CN72 WHITE TRANS IN 4 CN81 RED CHECK 5 CN76 YELLOW EXTERNAL OPTION PCB CONNECTER 6 CN77 RED HOT COIL 7 CN74 YELLOW DRAIN PUMP 8 CN75 BLACK VENTILATOR 9 CN73 WHITE FAN MOTOR A 7 6 3 2 1 8 9 B ...

Page 368: ...use use K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil not use use K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control not use N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 369: ... EXTERNAL CONTROL CN62 BLUE EEV CN91 WHITE DISPLAY CN10 BLACK MICOM DOWNLOAD CN31 RED COMM1 OUTDOOR CN33 BLUE COMM2 REMOCON No CN COLOR FUNCTION 1 CN11 RED TRANS OUT 2 CN71 BLUE AC POWER 3 CN72 WHITE TRANS IN 4 CN81 RED CHECK 5 CN76 YELLOW EXTERNAL OPTION PCB CONNECTER 6 CN77 RED HOT COIL 7 CN74 YELLOW DRAIN PUMP 8 CN75 BLACK VENTILATOR 9 CN44 BLUE HALL IC 0 CN78 WHITE FAN MOTOR A 7 6 3 0 2 1 8 B ...

Page 370: ...ump N A N A K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping N A N A K11 External Control not use use K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 371: ... CAPACITOR CN71 BLUE AC POWER CN45 WHITE REMOCON RECEIVER CN32 BLUE COMM2 REMOCON CN31 RED COMM1 OUTDOOR CN43 WHITE REMOCON DC12V CN41 WHITE ROOM EVA IN SENSOR No CN COLOR FUNCTION CN42 WHITE EVA OUT SENSOR CN44 BLUE HALL IC 1 CN91 WHITE DISPLAY 2 CN63 WHITE AUTO GRILLE 3 CN61 WHITE LOUVER 4 CN93 WHITE MICOM DOWNLOAD 5 CN62 BLUE EEV A B ...

Page 372: ... ON OFF K1 Wired remote control not use use K2 Centralized control N A N A K3 Heating thermo off 2 C 5 C K4 Min EEV step at heating fix 80step 0 or 80step B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 373: ...Samsung Electronics 10 17 PCB Diagram 10 1 9 Wall mounted type Prestige 1 2 3 5 A B 4 MAIN PCB SUB PCB ...

Page 374: ...0 BLACK DOWNLOAD CONNECTOR 4 CN62 BLUE EEV SUB PCB 5 CN61 BLACK MAIN SUB CONNECTOR No SW Function ON OFF K1 Wired remote control not use use K2 Centralized control not use use K3 RPM up not use use K4 Option drain pump N A N A K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80st...

Page 375: ...ON DC12V CN31 RED COMM1 OUTDOOR CN33 BLUE COMM2 REMOCON CN91 WHITE DISPLAY CN81 RED CHECK CN42 WHITE EVA OUT SENSOR No CN COLOR FUNCTION 1 CN41 WHITE ROOM EVA IN SENSOR 2 CN83 RED EXTERNAL CONTROL 3 CN51 BLACK FLOAT S W 4 CN76 YELLOW EXTERNAL OPTION PCB CONNECTER 5 CN61 BLUE LOUVER 6 CN11 RED TRANS OUT 7 CN72 WHITE TRANS IN 8 CN10 BLACK MICOM DOWNLOAD 9 CN62 BLUE EEV A B 1 2 3 4 5 6 7 ...

Page 376: ...p N A N A K5 Heating thermo off 2 C 5 C K6 Filter signal display 1 000hr 2 000hr K7 Hot water coil N A N A K8 Electrical heater N A N A K9 Min EEV step at heating fix 80step 0 or 80step K10 Transmitter grouping 0 to 15 16 to 31 K11 External Control N A N A K12 Preparation B No SW Function SW01 SW02 SW03 SW04 Main address set 00 99 Centralized control address set 00 FF A ...

Page 377: ...m Temperature SMW250 06 WHT 34 Cond mid Temperature SMW250 06 WHT 56 Cond out Temperature SMW250 06 WHT Download SMW200 10 WHT Interface Module YW396 02 BLU 1 Fan 1 YW396 07AV BLU 2 Fan 2 YW396 07AV YEL 3 4 way Valve YW396 03AV YEL 4 PWM Valve YW396 03AV WHT 5 Compressor YW396 03AV WHT 6 Hot Gas Bypass Valve YW396 05AV BLU 7 Liquid Bypass Valve YW396 03AV BLK 8 CCH YW396 07AV RED 9 Main Power YW39...

Page 378: ...ELLOW 3 PHASE INPUT CN70 BLACK 220V INPUT CN75 WHITE COMP1 CCH CN76 BLACK COMP2 CCH CN77 RED COMP3 CCH CN81 BLACK OIL VALVE 1 CN82 YELLOW OIL VALVE 2 No CN COLOR FUNCTION CN80 RED OIL VALVE 3 CN79 WHITE LIQUID TUBE VALVE CN72 BLUE COMP CONTROL 1 CN74 RED HOTGAS VALVE 2 CN71 WHITE PWM VALVE 3 CN73 YELLOW 4WAY VALVE ...

Page 379: ...ACK MAIN MICOM DOWN OPT1 WHITE CO HP SELECT CN51 YELLOW COMP1 CT INPUT CN52 BLUE COMP2 CT INPUT CN53 RED COMP3 CT INPUT No CN COLOR FUNCTION 1 CN41 BLUE LOW SENSOR 2 CN12 RED HIGH SENSOR 3 CN44 WHITE COMP SUCTION SENSOR 4 CN64 BLUE LIQUID EEV 5 CN63 YELLOW EEV2 6 CN47 WHITE OIL 2TUBE COND SENSOR 7 CN62 BLUE EEV 8 CN49 BLUE OUTAIR SENSOR 9 CN45 YELLOW SUMP SENSOR 0 CN99 WHITE DC SIGNAL TO POWER PCB...

Page 380: ...N COLOR FUNCTION CN71 BLUE 220V POWER INPUT CN98 WHITE EARTH CONNECT GT2 SILVER 220V TRANS INPUT CN70 BLACK 220V POWER OUTPUT No CN COLOR FUNCTION CN72 WHITE DC310V FAN INPUT CN11 RED AC17V 9V OUTPUT CN73 WHITE FAN IN OUT SIGNAL CN99 WHITE DC SIGNAL TO MAIN PCB ...

Page 381: ...Samsung Electronics 10 25 PCB Diagram 10 3 4 CT PCB No CN COLOR FUNCTION PCB CODE YELLOW COMP1 CT OUTPUT DB93 03531A CN61 RED COMP2 CT OUTPUT DB93 03531B BLUE COMP3 CT OUTPUT DB93 03531C ...

Page 382: ...nd the oil return very well for system operation No electromagnetic interference issue Pressure chamber of the Digital Scroll compressor This cross section shows the top part of the Digital Scroll compressor It is designed for efficiency reliability and durability The Digital Scroll can give a capacity range of 10 to 100 which is the widest in the industry It has very excellent performance and nee...

Page 383: ... if the scrolls are loaded for 10 seconds and unloaded for 10 seconds the time averaged capacity is 50 The to control the cooling heating system automatically The PWM valve is designed specially as a solenoid valve to modulate the pressure forcing on the fixed scroll and finally working on the compressor s loading unloading between the upper part of the fixed scroll and the suction pipe The PWM re...

Page 384: ...nd finally determines the refrigerant flow rates directly linked with EEV steps Unloaded power consumption is 10 of full load power in 6 0HP compressor The graph shows that the unloaded power consumption is 10 of full load power in case of 6 seconds loaded and 6 seconds unloaded In each cycle of modulation the discharge pressure builds up during the cycle is being loaded then the discharge pressur...

Page 385: ...for installing in the narrow area such as the kitchen Common air conditioners Multiple outdoor units Samsung mini DVM Only one outdoor unit The floor space for installation approx 38 reduced 880 638 320 932 1 128 375 2 5HP 2 5HP 5 0HP Easy Installation The refrigerant piping length between the outdoor and indoor unit at one system is short Its short piping enables the installation easier and more ...

Page 386: ...ze and thickness of refrigerant pipe Temper grade of piping material C1220T O Soft C1220T 1 2H Semi hard Minimal thickness mm Pipe size mm inch 0 8 0 8 0 8 1 0 1 0 ø6 35 1 4 ø9 52 3 8 ø12 70 1 2 ø15 88 5 8 ø19 05 3 4 Note The value in brackets indicates the length when the outdoor unit is lower than the indoor unit Outdoor unit The distance between the outdoor unit and the furthest indoor unit Dif...

Page 387: ...it Outdoor unit EEV kit The distance between the outdoor unit and the furthest indoor unit Difference of height between the outdoor and indoor unit m H1 30 25 Difference of height between the indoor units m H2 Maximum allowable length of pipe Maximum allowable height Maximum allowable length after the first Y joint 15 First Y joint Indoor unit less than 30m For example b c d j 30m b c g 30m Allowa...

Page 388: ...apacity 8 0 48 0HP Thus DVM Plus II is unique and ideal solution for your high standards 1 Various Capacity and 21 Combinations with Multi Module System 4 Base models 8 0 48 0HP 21 Combinations New HP 8 0 10 0 12 0 14 0 16 0 18 0 20 0 Outdoor unit Combinations Outdoor unit Combinations Outdoor unit Combinations Compressor HP 8 2 22 0 10 2 24 0 12 3 26 0 14 3 28 0 8 8 4 30 0 8 10 4 32 0 10 10 4 34 ...

Page 389: ...acity outdoor unit in minimal space Reduced 42 1 6m2 0 92m2 DVM Plus DVM Plus II 3 Reduction of Unit Weight DVM Plus 2 only weighs 330kg and its total volume is 1 53m3 based on 14 0HP Therefore it s available for lifting by elevator You don t need to lift up DVM Plus II with heavy machinery like a crane Thus you can reduce costs DVM Plus 2 DVM Plus 10 0HP 14 0HP 28 0HP 26 Reduced 42 Reduced 13 Red...

Page 390: ...hen the outdoor temperature is up to 43 C or down to 20 C 5 Long Piping Long piping allows flexible and convenient installation of DVM Plus 2 Cooling Heating 21 C 15 C 20 C Outdoor temperature DVM Plus 2 Advanced DVM Plus 43 C 5 C DVM Plus 2 DVM Plus 50m Actual piping length 170m Equivalent piping length 190m Total piping length 300m 5m 15m 45m ...

Page 391: ...e high pressure of the refrigerant for smooth operation This system helps PWM compressor maintain itself to operate for a long time with reliability of performance 7 Small Connection Pipe DVM Plus 2 adopts refrigerant R410A As a result you can experience higher energy efficiency and smaller piping diameter 5m difference of height Gas pipe Ø44 45 Liquid pipe Ø19 05 R407C R22 Gas pipe Ø31 75 Liquid ...

Page 392: ...roblem to the main system After the compressor has stopped the other compressors inside the same outdoor unit or different unit continue operating with balance Therefore it is reducing inconvenience while repairs are made Off Off On On Stop Service call Trouble Alarm Back up Running Off On On On On On On On On On Running Broken ...

Page 393: ...the electronics are simple and oil return issues are eliminated No electromagnetic interference 2 Pressure Chamber of the Digital Scroll Compressor This cross section shows the top part of the Digital Scroll compressor It is designed for efficiency reliability and durability The Digital Scroll can give a capacity range of 10 to 100 which is the widest in the industry It has very excellent performa...

Page 394: ...e with capacity demanded Pressure autonomic dispersion control 4 The to Control the Cooling System Automatically The PWM valve is designed specially as a solenoid valve to modulate the pressure forcing on the fixed scroll and controlling the compressor s loading unloading The PWM receives the On Off signal and controls the loading unloading status When the PWM valve is turned off the fixed scroll ...

Page 395: ... used by the Digital Scroll compressor The indoor units senses not only the temperature difference between inlet and outlet of evaporator but also the superheat and room temperature profiles and finally determines the refrigerant flow rates directly linked with EEV steps 1 0 5 0 0 5 1 ΔQ 3 ΔQ 3 ΔQ 0 ΔQ 2 ΔQ 2 Falling room temperature Rising room temperature Open electronic expansion valve Closed e...

Page 396: ... build up the pressure is a fraction of a second The average value is around 0 4 sec ond 2 Efficient Cooling and Heating System Wide capacity ranges providing greater comfort room temperature Precise temperature control Quick response to room demands Low starting energy Efficient and reliable heating performance Room temp 40 C Room temp 20 C Room temp 24 C 20Min 10Min User comfort declines Off On ...

Page 397: ...es the Digital Scroll system save Energy is saved more than 30 when compared to other conventional technologies Digital Scroll delivers exact capacity needed by the room Machine output can go as low as 10 Fewer start stops of compressor saves energy and increases life Very efficient when operating at part load Reduces energy consumption when demand is less Time Room 1 Room 2 Room 3 Multi evaporato...

Page 398: ...DOE Department of Energy investigated operating range of chillers in 29 cities during 25 Years Based on this data weighting of part load point in efficiency calculation for chillers are established Weighting of part load point 1998 ASHRAE Standard AIR 550 590 1998 Standard 1992 Standard 0 Load 100 75 50 20 20 50 75 1 17 42 39 45 33 12 11 100 Weighting of 75 50 part load becomes increased ...

Page 399: ... Scroll compressor can reduce peak power consumption and save energy in most commercial buildings 12 1kW Samsung DSC Power input at 100 load kW A company s inverter B company s inverter 14 3kW 13 0kW Power input 6 Cooling COP Comparison with Inverter COP efficiency is 40 higher than other systems for DVM 10 0HP It was measured in Samsung multi calorimeter by KSC 9306 at the same condition Test Con...

Page 400: ...er have relatively low heat transfer area The Wide fin solve this problem and increase capacity and EER W slit FP1 3 W slit FP1 5 W slit FP1 7 Slit FP1 3 Slit FP1 5 100 80 60 40 20 0 4 00 3 50 3 00 2 50 2 00 1 50 Pressure drop Pa 0 5 1 1 5 2 2 5 3 Air velocity in 120 110 100 90 80 70 Pressure drop Pa W slit FP1 3 W slit FP1 5 104 9 124 7 107 7 111 Pressure drop Capacity Slit Fin Wide Slit Fin Shap...

Page 401: ...he indoor unit If the outdoor unit is located underneath the indoor unit the level difference would be a maximum of 40meters Equivalent piping length between outdoor and indoor units 190meter DVM Plus2 The distance from the first refnet joint to the indoor unit 45meters DVM Plus2 1 5 m H e ig h t b e tw e e n in d o o r u n it s 5 0 m H e ig h t b e tw e e n in d o o r a n d o u td o o r u n it 1 ...

Page 402: ...agement to prolong system life Outdoor chamber Indoor chamber Test of operation under low temperature and 50meter fall Condition under 20 C indoor and 5 C outdoor Condition under the minimum oil level of Compressor Refrigerant of an accumulator added Measured data Capacity Oil level Liquid back Starting Outdoor air temp etc Digital Scroll Minimum oil level Normal Scroll Compressor 10 12 14 16 18 2...

Page 403: ...cs 11 22 4 Space Saving Compared to the conventional system DVM system saves much more space because one single outdoor unit manages many indoor units resulting in maximizing your space Conventional system DVM System Space can be utilized for other activities ...

Page 404: ...T080GA RVXVHT140GA RVXFHT140GA RVXFHT100GA RVXVHT140GA RVXFHT140GA RVXFHT120GA RVXVHT140GA RVXFHT140GA RVXVHT140GA RVXFHT100GA RVXVHT140GA RVXFHT120GA RVXFHT100GA RVXVHT140GA RVXFHT140GA RVXFHT100GA 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 45 0 50 5 56 0 61 5 68 0 73 5 80 0 84 0 89 5 96 0 102 5 108 0 113 5 120 0 124 0 129 5 136 0 22 5 58 5 25 3 65 7 28 0 72 8 30 8 80 0 34 0 88 4 36 8 95 ...

Page 405: ...r unit Digital Fixed Fixed Connection of the power cable 3 phase 3 wires and 1 phase Distribution board 3 phase 4 wires 380 415V 1 phase 220V Wired remote control Earth Outdoor unit Indoor unit Outdoor communication cable Indoor communication cable ELB Earth ELB Digital Fixed Fixed 220V Connect the communication cable between indoor and outdoor units to the digital outdoor unit RVXVHT If the commu...

Page 406: ... the first Y joint Use the copper pipe of semi hard 1 2H when installing the pipe of ø19 05 If you use Soft O pipe the internal pressure is too low to cause personal injury Use manifold gauge only for R410A to prevent the inflow of foreign substances Use only flare nut supplied with the product Use vacuum pump with check valve to prevent pump oil from flowing backward while the vacuum pump is stop...

Page 407: ...8 indoor units Using only Y joint When installing 1 outdoor unit 8HP 14HP Using Y joint and branch joint When installing 1 outdoor unit 8HP 14HP Outdoor unit Y joint Outdoor unit Y joint Branch joint When installing more than 1 outdoor unit 16HP 48HP Outdoor unit Y joint When installing more than 1 outdoor unit 16HP 48HP Outdoor unit Y joint Branch joint ...

Page 408: ...utdoor unit 8HP 14HP Outdoor unit Branch joint When installing more than 1 outdoor unit 16HP 48HP Outdoor unit Branch joint Cautions for installing outdoor unit pipe The connected pipe should be placed lower than service valve The connected pipe should be connected from the side of the air conditioner Fixed Fixed Digital The digital variable outdoor unit of the system should be placed in the end o...

Page 409: ...nce from the outdoor unit to all indoor units 300m The distance between the outdoor joint and the outdoor unit 10m Equivalent length 13m H1 Difference of height between the outdoor unit and indoor unit 50m When the outdoor unit is lower 40m H2 Difference of height among the indoor units 15m H3 Difference of height among the outdoor units 5m The distance between the first Y joint and the indoor uni...

Page 410: ... mm Liquid side mm Selecting the refrigerant pipe A Between Y joints Select it depending on attached indoor units X 22 4 22 4 X 33 0 33 0 X 47 0 47 0 X 71 0 71 0 X 104 0 104 0 X ø9 52 ø9 52 ø12 70 ø15 88 ø19 05 ø19 05 ø15 88 ø22 23 ø25 40 ø28 58 ø31 75 ø 38 10 Indoor unit total capacity kW Gas side mm Liquid side mm B Among the outdoor units Depend on the total capacity of attached outdoor units X...

Page 411: ...ø6 35x10m i ø12 70x10m j ø6 35x10m k ø6 35 x 9m Liquid side pipe ø19 05 Total pipe length m X 0 27 Liquid side pipe ø15 88 Total pipe length m X 0 18 A A 14 33 30x0 27 10x0 18 10x0 125 40x0 06 39x0 02 Liquid side pipe ø12 70 Total pipe length m X 0 125 Liquid side pipe ø9 52 Total pipe length m X 0 06 Liquid side pipe ø6 35 Total pipe length m X 0 02 Pipe diameter mm ø22 23 ø19 05 ø15 88 ø12 70 ø9...

Page 412: ... Operating flow of outdoor unit E201 error tracking error Yes Yes Power on Tracking completed Yes No Preheating CCH For 2 5 hours Yes Is preheating of CCH completed No E425 error reverse phase open phase error Is 3 phase power OK No Normal operation ...

Page 413: ...nsmitters installed in the same system which is called as Tracking 1 The left side display shows the address of indoor unit with which the outdoor unit is trying to communicate 0 1 2 d E F 2 The right side display shows the address of indoor unit responding to the communication 3 The right side display displays together when the related indoor unit address displays at the left side For example if ...

Page 414: ...n E425 are indicated alternately and the air conditioner is kept to stop 1 Check the L19 R L2 S phase L1 R L3 T phase L2 S L3 T phase voltage 2 If there is any terminal with not having the normal voltage check the external power of the air conditioner and manage it 3 If the 3 phase power is normal check the phase of the power cable using 3 phase tester When reverse phase is displayed change the po...

Page 415: ...eck replace the PCB communication part indoor power power power Compressor indoor power supply line single phase AC230V supply line 3 phase power supply line communication line clamp mini DVM Series communication part power power Compressor OF1 OF2 R S T N 3 phase power supply line indoor communication line outdoor communication line single phase AC230V supply line DVM Plus Series ...

Page 416: ...outdoor unit displays and the responding address on the right part 3 If it is not the condition for the compressor operation at the moment Ch is kept flickering on the display part and CCH crank case heater heats the compressor for 2 and half hours The compressor cannot be operated for the time but can be operated if Ch disappears due to the sufficient heating for 2 and half hours 4 The check of o...

Page 417: ...t communication error for more than 2 minutes 2 Indoor unit receiving the communication error from outdoor unit 3 Outdoor unit tracking 3 minute error 4 When sending the communication error from outdoor unit due to the mismatching of the communication numbers and installed numbers after completion of tracking communication error for more than 2 minutes Displayed on appropriate indoor unit which is...

Page 418: ... Refrigerant complete leakage 2nd detection 7 COND high temperature 2nd detection 8 DISCHARGE high temperature 2nd detection 9 Low pressure switch 2nd detection COMP DOWN 10 Reverse phase detection error 11 Freezing 6th detection compressor stop 12 Compression sensor self diagnosis G8 G9 13 Compressor down error by compression ratio control Plot switch detection Peripheral control device option se...

Page 419: ...lay an item that requires more than 2 detections for deciding whether it is an error or not during the 1st detection Display the outdoor unit address that an error is occurred U200 Main Outdoor Unit U201 Sub 1 Outdoor Unit U202 Sub 2 Outdoor Unit U203 Sub 3 Outdoor Unit Display the indoor unit address that an error is occurred Ex A000 An error is occurred at number 0 address indoor unit A047 An er...

Page 420: ...tion when outdoor temperature is over 30 C Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15 C Forbid an operation by low pressure Equal oil valve 1 self diagnosis Communication error between indoor and outdoor unit When not received in every room after completing the tracking Communication error between the indoor unit and outdoor unit Pr...

Page 421: ...or When 1st detection Indoor unit EEV close failure When 2nd detection Indoor unit EEV close failure When 1st detection Indoor unit EEV open failure When 2nd detection Indoor unit EEV open failure When 1st detection Indoor unit EVA IN sensor breakaway Indoor unit EVA OUT sensor breakaway Indoor unit heater sensor error Digital comp1 Sump temperature sensor breakaway Fixed comp1 Sump temperature se...

Page 422: ...ent from the actual outdoor temperature replace the temperature sensor Forbid heat mode operation when outdoor temperature is over 30 C Outdoor unit display Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15 C Indoor unit display No display An error occurs and starting is prohibited right before starting the heat mode of the outdoor unit by...

Page 423: ... unit display Operation Timer Fan Filter Defrost Before the pump down start for 3 consecutive seconds when the low pressure sensor value high pressure sensor does not come under among Main Units is below 3 1kg cm2 G during cooling operation and below 2 6kg cm2 G during heating operation start is prohibited Impossible to restart and error display on the indoor unit Causes Refrigerant leakage low pr...

Page 424: ...ing step during the equal oil operation and open the Hot Gas Bypass if temperature is not changed by over 7 C the error is displayed Causes Oil valve equal oil valve temperature sensor breakaway oil valve equal oil valve 1 defect coil defect or terminal contact badness Is the oil valve 1 temperature sensor separated Insert the sensor correctly Yes No Is the temperature measuring value proper Using...

Page 425: ...lock defect Fan Motor Capacitor defect or Wire short Service Valve closeness Excess amount of refrigerant Is the service valve opened all Test operation Open the service valve No Connect the S net and Manifold Gauge Requisite Yes Is the measuring value of S net same as the value of the Manifold Gauge Replace the high pressure sensor No Yes Are the indoor unit and outdoor unit EEV operated normally...

Page 426: ... outside temperature is below 20 C during heating operation and when outside temperature is below 5 C during cooling operation the relevant error can be occurred Is the service valve opened all Test operation Open the service valve No Connect the S net and Manifold Gauge Requisite Yes Is the measuring value of S net same as the value of the Manifold Gauge Replace the low pressure sensor No Yes Are...

Page 427: ...fect EEV open error Check the indoor unit that freezing is detected Remove the obstacles of corresponding indoor unit and clean the dust filter Error reset Key 3 Operate the corresponding indoor unit only Is the indoor unit fan motor operated normally Operate when every room is cool Is high low pressure normal Completion Is the voltage of PCB fan motor output terminal normal After checking the con...

Page 428: ... of error occurrence Check the compressor that the error is occurred through S net Separate the temperature sensor from the compressor and leave it on the air for approximately 10 minutes Reattach the temperature sensor Complete the check Is the Loading or Unloading of the Digital compressor operated normally Is the temperature sensor attached correctly Is the Sump temperature value similar as the...

Page 429: ...rge Check Valve leakage of the outdoor unit on the stop side Is the compressor emission sensor resistance normal Refer to Is the service valve opened all Are the indoor unit and outdoor unit EEV operated normally Is there any clogged part in a piping Filter etc Is there any leakage on the liquid valve of the outdoor unit on the stop side or the emission Check Valve during some outdoor units are op...

Page 430: ...h is blocked Is the COND OUT sensor and sensor holder correctly attached Is the resistance value of the COND OUT sensor proper Refer to Stop Is there is any change of sensor value during heating operation Reinsert the sensor Reattach the sensor holder Sensor defect Replace the sensor The sensor side s path is blocked Replace the heat exchanger Ass y Completion No No No Yes Yes Yes OK OK OK OK NO O...

Page 431: ...tion No No Yes Yes Suction Temperature Sensor Breakaway 1 Check Method Outdoor unit display Indoor unit display Operation Timer Fan Filter Defrost Suppose the Suction temperature right before Comp start that has high priority of start Tsuc ini and the Suction temperature of current Comp Tsuc real When Tsuc real Tsuc ini 2 C condition maintains for 30 minutes the error is judged Causes Suction temp...

Page 432: ...r is displayed Causes Compressor break CT sensor defect Is the CT sensor connector resistance normal Is the CT value when compressor is stopped all 0 Is the value measured by the separate ampere meter same as CT sensor value Is the CT value measured over 20A during operation Replace the CT sensor Replace the CT sensor Connect the separate ampere meter Optional Replace the CT sensor Complete the ch...

Page 433: ... all Is the measuring value of S net same as the value of the Manifold Gauge Are the indoor unit and outdoor unit EEV operated normally Is there any clogged part in a piping Filter etc Is there any leakage on the liquid valve of the outdoor unit on the stop side or the emission Check Valve during some outdoor units are operated only Open the service valve Connect the S net and Manifold Gauge Requi...

Page 434: ...set the indoor unit power Is the same error occurred again Replace the indoor unit PCB Normally operated Reassemble the plot switch connector and reset the indoor and outdoor unit power Is the indoor unit that the error is occurred cassette type Is the amount of water which is gathered into the drain plate much Is the drain pump operated Is the terminal voltage of the drain pump PCB approximately ...

Page 435: ...each terminal of coils and the open and short on the coil inside 4 After pressing the outdoor unit Reset Key K3 check that same error is occurred In case close error do not operate the indoor unit that the error is occurred In case open error do not operate the indoor unit that the error is occurred 5 If no error is checked for the above check points replace the relevant indoor unit EEV The replac...

Page 436: ...the open and short on the coil inside 4 After pressing the outdoor unit Reset Key K3 check that same error is occurred In case close error do not operate the indoor unit that the error is occurred In case open error do not operate the indoor unit that the error is occurred 5 If no error is checked for the above check points replace the relevant indoor unit EEV The replacement of EEV is inconvenien...

Page 437: ...r Fan Filter Defrost Judgment method Refer to the below judgment method Causes Indoor heat exchanger EVAP IN piping sensor breakaway OK NO OK OK Indoor heat exchanger EVAP IN sensor breakaway Tcond out Tair out 3 C Tair in Teva in 4 C Tair in Teva out 4 C Compressor running indoor unit on and thermo on Error contents OK OK OK NO OK OK Indoor heat exchanger EVAP IN sensor breakaway High pressure av...

Page 438: ...Timer Fan Filter Defrost Judgment method Refer to the below judgment method Causes Indoor heat exchanger EVAP IN sensor breakaway OK OK NO OK Indoor heat exchanger EVAP IN sensor breakaway Tcond out Tair out 3 C Tair in Teva in 4 C Tair in Teva out 4 C Compressor running indoor unit on and thermo on Error contents OK OK NO OK OK OK Indoor heat exchanger EVAP IN sensor breakaway High pressure avera...

Page 439: ...ump real Tsump ini 2 C maintains for 60 minutes after compressor is started the error is judged After 60 minutes after compressor is started do not perform the detection of the Sump temperature sensor breakaway 2 Check Method After checking whether the relevant compressor sensor is broken away by the error code or not assemble and adjust Outdoor unit display Digital compressor or fixed 1 compresso...

Page 440: ...eration Timer Fan Filter Defrost 1 Relevant compressor current value CT sensor value is over 5A 2 Relevant compressor emission temperature High pressure saturation temperature When detect the above 1 and 2 conditions are detected for over 30 minutes continuously Causes Compressor Discharge sensor breakaway error Sensor defect Outdoor unit display Judgment method Are the emission temperature sensor...

Page 441: ...0 Is the compressor not operated even though the Magnetic Contactor is contacted Is the CT value measured below 4A during operation Is the CT value measured below 4A during operation Replace the CT sensor Replace the CT sensor Connect the separate ampere meter Optional Replace the CT sensor Complete the check Check the Magnetic Contactor and whether OLP Trip If the compressor break is judged repla...

Page 442: ...re of the outdoor Fan Motor operated is overheated at over 110 C Causes Indoor unit Fan Motor lock or defect Outdoor Unit Fan Motor RPM Error 1 Check Method 1 The system is programmed that operating by attempting to restart several times to operate the motor if an error signal is generated on the starting defect If the motor is operated there is no error 2 Check whether the outdoor unit Fan Motor ...

Page 443: ...mperature of IPM during the operation of the outdoor Fan Motor is over 150 C Causes Indoor unit Fan Motor lock or starting defect Outdoor Unit Fan Motor Over Current Error 1 Check Method 1 Check whether the outdoor unit Fan Motor is rotated and locked or not 2 When the above error is occurred in case there is no lock the signal by overload and error action is judged The signal is to display the mo...

Page 444: ...o start under reverse rotation condition by checking the moving status when the power of the outdoor unit fan motor is not turned on 2 Check there is outside wind which can rotate the fan by force in the place where the outdoor unit is installed Outdoor unit display Indoor unit display Judgment method When the rotation direction of the outdoor unit Fan Motor is rotated reversely before starting Ca...

Page 445: ...room temperature sensor Is separated the indoor unit room temperature sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor room temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor room temperature sensor because it is...

Page 446: ...the no indoor unit EVAP IN sensor Is separated the indoor EVAP IN sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor EVAP IN connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor EVAP IN sensor because it is defect Yes Yes Yes No No Tem...

Page 447: ...he no indoor unit EVAP OUT sensor Is separated the indoor EVAP OUT sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor EVAP OUT connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor EVAP OUT sensor because it is defect Yes Yes Yes No No ...

Page 448: ... gives feedback of RPM valve 2 In case the fan motor starting Capacitor is PCB separate type check the connection terminal 3 Check the fan motor starting status 4 If no error is checked for the above check points replace the PCB Outdoor unit display A Indoor unit address which an error is occurred Indoor unit display Operation Timer Fan Filter Defrost Judgment method Refer to the below judgment me...

Page 449: ... connected from the outdoor unit to the indoor unit If there is no defect search the indoor unit that interrupts the communication by connecting the indoor unit one by one After pre checking the wire replace the indoor unit PCB Is the voltage between both wires square wave over DC 0 7V Is same the actual indoor unit installation number and the setting switch s setup value for the indoor unit insta...

Page 450: ...n wire connected from the outdoor unit to the indoor unit and then measure 2 wires of the outdoor unit with scope Check the communication wire connected from the outdoor unit to the indoor unit If there is no defect search the indoor unit that interrupts the communication by connecting the indoor unit one by one After pre checking the wire replace the indoor unit PCB Search for the indoor unit dis...

Page 451: ...d the outdoor temperature sensor connector from PCB Is the resistance value far from the temperature table Detach the outdoor temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor temperature sensor because it is defect Yes Yes Yes No No Temperature C 70 60 50 40 ...

Page 452: ...he resistance value far from the temperature table Detach the outdoor discharge temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor heat exchanger temperature sensor because it is defect Yes Yes Yes No No Temperature C 130 120 100 80 60 25 20 10 0 10 Resistance ...

Page 453: ...nt speed compressor Discharge temperature sensor connector from PCB Is the resistance value far from the temperature table Detach outdoor constant speed compressor discharge temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor constant speed compressor discharge ...

Page 454: ...mer Fan Filter Defrost Judgment method Refer to the below judgment method Causes Open or short of the corresponding sensor Low Pressure Sensor Error Open Short Low pressure High pressure sensor open short error detection method 1 During the oil collection operation omit the error detection and start the detection after 5 minutes from the completion of the operation 2 During the safety starting ope...

Page 455: ...Is separated the outdoor oil temperature sensor connector from PCB Is the resistance value far from the temperature table Detach outdoor oil temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor oil temperature sensor because it is defect Yes Yes Yes No No Tempera...

Page 456: ...Is separated the outdoor COND OUT sensor connector from PCB Is the resistance value far from the temperature table Detach outdoor COND OUT sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor COND OUT sensor because it is defect Yes Yes Yes No No Temperature C 70 60 50 40 30...

Page 457: ...ted the dual pipe temperature sensor connector from PCB Is the resistance value far from the temperature table Detach the dual pipe temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the dual pipe temperature sensor because it is defect Yes Yes Yes No No Temperature C 70 6...

Page 458: ...mpare to the 3 phase defect circuit wave If the phase voltage is returned to normal error is automatically released Causes 3 phase power L1 R L2 S L3 T open error or not input 3 phase power Check the main voltage Is error occurred again After switching off the power breaker exchange the 2 lines among the three lines of 3 phase inlet and check it again Is the voltage between red white white black r...

Page 459: ...r Defrost Judgment method Temporary stop of the compressor by instant power off Causes Compressor protecting action status Not an error EEPROM Error Outdoor unit display Indoor unit display Operation Timer Fan Filter Defrost Judgment method Impossible to communicate between EEPROM and MICOM Causes Replace PCB due to EEPROM defection ...

Page 460: ...nit display Judgment method Refer to the below judgment method Causes Communication inferiority between outdoor units Error reset Key 3 Check the cut cable of the outdoor communication cable Replace the PCB Is the power supply normal 12V 5V Check the outdoor unit having errors U200 U201 U202 and U203 Check the outdoor unit setting option K13 K14 Check the power cut cable changing or connection Cha...

Page 461: ... outdoor unit Breakaway of condenser out temperature sensor in outdoor unit Error of discharge temperature sensor Open or Short Breakaway of discharge temperature sensor in outdoor unit Compressor down due to frozen evaporator of indoor unit High temperature of discharge Protection control Reverse phase error Protection control Over 30 C when heating Below 5 C when cooling Over 15 C when charging ...

Page 462: ...room temperature sensor Is separated the indoor unit room temperature sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor room temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor room temperature sensor because it is...

Page 463: ...the no indoor unit EVAP IN sensor Is separated the indoor EVAP IN sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor EVAP IN connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor EVAP IN sensor because it is defect Yes Yes Yes No No Tem...

Page 464: ...he no indoor unit EVAP OUT sensor Is separated the indoor EVAP OUT sensor connector from PCB Is the resistance value far from the temperature table Detach the indoor EVAP OUT connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the indoor EVAP OUT sensor because it is defect Yes Yes Yes No No ...

Page 465: ...r Fan Filter Defrost Judgment method Refer to the below judgment method Causes Indoor heat exchanger EVAP IN piping sensor breakaway OK NO OK OK Indoor heat exchanger EVAP IN sensor breakaway Tcond out Tair out 3 C Tair in Teva in 4 C Tair in Teva out 4 C Compressor running indoor unit on and thermo on Error contents OK OK OK NO OK OK Indoor heat exchanger EVAP IN sensor breakaway High pressure av...

Page 466: ...Timer Fan Filter Defrost Judgment method Refer to the below judgment method Causes Indoor heat exchanger EVAP IN sensor breakaway OK OK NO OK Indoor heat exchanger EVAP IN sensor breakaway Tcond out Tair out 3 C Tair in Teva in 4 C Tair in Teva out 4 C Compressor running indoor unit on and thermo on Error contents OK OK NO OK OK OK Indoor heat exchanger EVAP IN sensor breakaway High pressure avera...

Page 467: ...the open and short on the coil inside 4 After pressing the outdoor unit Reset Key K3 check that same error is occurred In case close error do not operate the indoor unit that the error is occurred In case open error do not operate the indoor unit that the error is occurred 5 If no error is checked for the above check points replace the relevant indoor unit EEV The replacement of EEV is inconvenien...

Page 468: ...each terminal of coils and the open and short on the coil inside 4 After pressing the outdoor unit Reset Key K3 check that same error is occurred In case close error do not operate the indoor unit that the error is occurred In case open error do not operate the indoor unit that the error is occurred 5 If no error is checked for the above check points replace the relevant indoor unit EEV The replac...

Page 469: ...set the indoor unit power Is the same error occurred again Replace the indoor unit PCB Normally operated Reassemble the plot switch connector and reset the indoor and outdoor unit power Is the indoor unit that the error is occurred cassette type Is the amount of water which is gathered into the drain plate much Is the drain pump operated Is the terminal voltage of the drain pump PCB approximately ...

Page 470: ... connected from the outdoor unit to the indoor unit If there is no defect search the indoor unit that interrupts the communication by connecting the indoor unit one by one After pre checking the wire replace the indoor unit PCB Is the voltage between both wires square wave over DC 0 7V Is same the actual indoor unit installation number and the setting switch s setup value for the indoor unit insta...

Page 471: ...re connected from the outdoor unit to the indoor unit and then measure 2 wires of the outdoor unit with scope Check the communication wire connected from the outdoor unit to the indoor unit If there is no defect search the indoor unit that interrupts the communication by connecting the indoor unit one by one After pre checking the wire replace the indoor unit PCB Search for the indoor unit display...

Page 472: ...d the outdoor temperature sensor connector from PCB Is the resistance value far from the temperature table Detach the outdoor temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor temperature sensor because it is defect Yes Yes Yes No No Temperature C 70 60 50 40 ...

Page 473: ...Is separated the outdoor COND OUT sensor connector from PCB Is the resistance value far from the temperature table Detach outdoor COND OUT sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor COND OUT sensor because it is defect Yes Yes Yes No No Temperature C 70 60 50 40 30...

Page 474: ...g sensor Is separated the outdoor unit COND MID sensor connecter from PCB Is the resistance value far from the temperature table Detach the outdoor heat exchanger temperature sensor connecter from PCB and measure the resistance value between the both terminals Restart after PCB exchange Restart after connecting a connecter to PCB Replace the outdoor heat exchanger temperature sensor because it is ...

Page 475: ...h is blocked Is the COND OUT sensor and sensor holder correctly attached Is the resistance value of the COND OUT sensor proper Refer to Stop Is there is any change of sensor value during heating operation Reinsert the sensor Reattach the sensor holder Sensor defect Replace the sensor The sensor side s path is blocked Replace the heat exchanger Ass y Completion No No No Yes Yes Yes OK OK OK OK NO O...

Page 476: ...Out Sensor is detected in the condition that it is under heating test operation and the capacity of compressor is the maximum ste 20 step 3 Heating operation The following conditions should be satisfied for 20 minutes 2 Check method Check if the corresponding outdoor unit COND OUT sensor is separated according to the error code assemble and adjust it Teva in Tair in 3 C Teva out Tair in 2 C Tcond ...

Page 477: ...he resistance value far from the temperature table Detach the outdoor discharge temperature sensor connector from PCB and measure the resistance value between the both terminals Restart after replacing PCB Restart after connecting a connector to PCB Replace the outdoor heat exchanger temperature sensor because it is defect Yes Yes Yes No No Temperature C 130 120 100 80 60 25 20 10 0 10 Resistance ...

Page 478: ...of 40 C E262 error I Tdisc d Tdisc f1 I In case of 40 C E263 error I Tdisc d Tdisc f1 I In case of 40 C E264 error 2 Check method Check if the corresponding compressor sensor is separated according to the error code assemble and adjust it Display method of the order and number of compressor In case of 4 compressors Front Digital compressor Control Box Control Box Outdoor unit display Indoor unit d...

Page 479: ...d to check the system Test operation for every room KEY 4 Operate a corresponding indoor unit Remove the obstacles of corresponding indoor unit and clean the dust filter Does operate normally the indoor unit fan motor Is the voltage of PCB fan motor output terminal normal Replace the motor after checking the connection wire of fan motor After checking the quantity of refrigerant if needed recharge...

Page 480: ...erature is over 30 C at the right before of compressor start prohibit heating operation Operation prohibit mode according to the limit of outdoor temperature Check method The above error code is not the products error but specification to protect the products by restricting the use temperature ranges Use it by reference to the temperature range of use condition in manual If the above error code is...

Page 481: ...sor or OLP Trip 1 Judge method 1 Cooling operation 2 Heating operation Tcond out Tair out 3 C Tair in Teva in 4 C Tair in Teva out 4 C Compressor running indoor unit on and thermo on Error contents NO NO NO OK Loading failure or OLP Trip High pressure average 15kg cm2 Low pressure average 5kg cm2 Teva out Tair in 3 C Teva in Tair in 2 C Tcond out Tair out 2 C Compressor running indoor unit on and ...

Page 482: ...n though ON signal is going to compressor but if it is not operated it is the OLP trip due to the overload Wait until the compressor is cooled to restart Error reset KEY 3 Test operation for every room KEY 4 No No Yes Yes Yes No The replacement of PWM valve due to the loading failure is the difficult work to abolish the refrigerant in the system and recharging it and there is little possibility to...

Page 483: ... method Causes Oil collection operation Not error Oil collection operation 1 Check method This is the special operation mode to recollect oil discharged from the compressor and it is entered for 3 minutes in 7 hours interval It returns to the normal operation after oil collection operation for 3 minutes automatically ...

Page 484: ...MEMO 12 73 Samsung Electronics ...

Page 485: ... Capacitor Fan Motor Driver SSR TYPE Extra 1 Display interface 2 Sensor Input room eva in out 3 Program download interface 4 External PBA interface 5 EEV DRIVE 6 BUZZER DRIVE Setting Part 1 Main Rmc Address 2 Operation Condition Power Generation Part 1 SMPS 2 LINEAR Communication Part 1 Wired Remocon 2 Outdoor Unit MPU ...

Page 486: ...red Remocon 2 Outdoor Unit Extra 1 Display interface 2 Sensor Input room eva in out 3 EEV DRIVE External PBA Interface External PBA Interface 1 Main Rmc Address 2 Operation Condition MPU 1 Program download interface 2 BUZZER DRIVE Power Generation Part 1 Rectifier 2 Linear Regulator 13 1 2 2 way cassette type ...

Page 487: ...Setting Part 1 Main Rmc Address 2 Operation Condition BUZZER DRIVE 1 Power Input 2 Noise Filter Communication Part 1 Wired Remocon 2 Outdoor Unit Extra 1 Display interface 2 Sensor Input room eva in out 3 EEV DRIVE MPU Program Download interface Power Generation Part 1 Rectifier 2 Linear Regulator ...

Page 488: ...entilator Indoor FAN SSR Control Address Option Setting Switch 485 Communication Sensor Room Eva in out temp Floating Switch Indoor Louver Control EEV External Control Signal External Status Output Display Micom Program Download Wired Remocon 12V Power Comm Between Wired Remocon units ...

Page 489: ... Fan Motor Driver TAP TYPE Setting Part 1 Main Rmc Address 2 Operation Condition Program Download interface 1 Noise Filter Communication 1 Wired Remocon 2 Outdoor Unit MPU Power Generation 1 Rectifier 2 Linear Regulator Extra 1 Display interface 2 Sensor Input room eva in out 3 EEV DRIVE ...

Page 490: ...n Rmc Address 2 Operation Condition 1 Power Input 2 Noise Filter Communication Part 1 Wired Remocon 2 Outdoor Unit MPU Power Generation 1 Rectifier 2 Linear Regulator Extra 1 Display interface 2 Sensor Input room eva in out 3 EEV DRIVE Program Download interface Fan Motor Driver SSR TYPE ...

Page 491: ...Fan Motor Driver SSR TYPE Setting Part 1 Main Rmc Address 2 Operation Condition BUZZER DRIVE 1 Program download interface 2 EEV DRIVE 3 LOUVER Communication 1 Wired Remocon 2 Outdoor Unit 1 Sensor Input room eva in out 2 Display interface 3 AUTO GRILLE MPU Power Generation Part 1 Rectifier 2 Linear Regulator ...

Page 492: ...ilter 3 Fan Motor Driver SSR TYPE F U S E Buzzer Driver Power Generation 1 Rectifier 2 Linear Regulator Communication Part Wired Remocon Outdoor Unit Extra Sensor Input room eva in out LOUVER IONIZER External PBA Interface 1 Main Rmc Address 2 Operation Condition MPU 1 Program download interface 2 EEV Display interface ...

Page 493: ...tting Part 1 Main Rmc Address 2 Operation Condition Program Download interface BUZZER DRIVE 1 Program Input 2 Noise Filter Communication 1 Wired Remocon 2 Outdoor Unit MPU Power Generation Part 1 Rectifier 2 Linear Regulator Extra 1 Display interface 2 Sensor Input room eva in out 3 EEV DRIVE ...

Page 494: ...mm Control Non polarity Indoor Unit Setting Up Option S W Outdoor Unit Display Key Special Operation Control 3 Phase Detection part Outdoor Unit Temperature Pressure Sensor Low pressure Switch Electronic Expansion Valve Control Outdoor Unit Fan Control Outdoor Unit Load Control Comp Bypass V V Sol V V CCH Download Transmitter Power 12V MAIN PCB ...

Page 495: ...ure High Pressure Out air temp suction temp etc 2 EEV1 EEV2 Liquid EEV 3 phase mis wiring Detection Part 7 segment display Key operation Tact switch COMP CT Sensor Input Valve Drive Part CCH OIL LIQUID TUBE PWM COMP HOTGAS 4WAY Communication Part 1 Wired Indoor unit 2 Wired Outdoor Unit MAIN MPU SUB MPU Setting Part 1 Indoor Number 2 Operation Condition ...

Page 496: ...Power Input Surge Protector Linear Regulator For main PBA Motor Drive Interface Noise Filter AC Power Rect For main PBA SMPS for Motor Driver 15 V DC LINK Charging Part DC LINK RECTIFIER Capacitor AC Power Rectifier Interface with Main PBA Current Transducer ...

Page 497: ...6 000W 24K 7 200W 7 100W 28K 8 300W 9 000W 36K 10 500W 11 200W 44K 12 800W 12 800W 48K 14 000W 14 000W Rating Voltage 115V 60Hz A 220V 60Hz B 208 230V 60Hz C 200 220V 50Hz D 220 240V 50Hz E 127V 50Hz M Products Cassette C Duct D CONVERTIBLE T RAC W PAC P Mode C O C H P H H P Heater E C O Heater G C O Hot Water Heater N O O O C 1 H AVM B 052 1 A model name M R22 X R410A I N D O O R Design 1 way 1 2...

Page 498: ...p T Etc N O O O X C F RVM B 100 1 A model name M R22 X R410A Chassis Variable V Fixed F mini DVM M DVM SLIM S GHP G Twin Multi T Home DVM H WDVM D WPAC P O U T D O O R DVM Plus2 Capa x1 10kW HP 3 Digit Rating Voltage 115V 60Hz A 220V 60Hz B 208 230V 60Hz C 200 220V 50Hz D 220 240V 50Hz E 208 230V 60Hz 3ø F 380 415V 50Hz 3ø G 127V 50Hz M 380V 60Hz 3ø H 460V 60Hz 3ø J 200V 60Hz 3ø K Version A Z Expo...

Page 499: ... setting switch of indoor unit installation number Example If 3 indoor units are installed adjust the arrow of switch to 3 Note The display method of English characters and figures on PCB display part The number of indoor unit installation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 A B C D E F 0 The number of switch 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X ...

Page 500: ... time K1 SEG 3 4 display K2 SEG 3 4 display K3 SEG 3 4 display K4 SEG 3 4 display Heating refrigerant supplement Heating test operation Completion Cooling refrigerant supplement Cooling test operation Refrigerant collection Pump down Completion Reset Data display g SEG1 a f G1 G2 b c e d SEG2 g SEG3 a f G1 G2 b c e d SEG4 K1 K2 K3 K4 Check Mode Reset View Mode Reset View Mode ...

Page 501: ...Target Sum Temp 2 C Normal capacity x115 outlet On Tr 27 C Target Sum Temp 3 C COOL HEAT COOL HEAT COOL HEAT COOL HEAT The number of times Remark Contents Display Example The step of outdoor valve Cond Out Temperature Cond Mid Temperature The temperature of outdoor The outlet temperature of compressor HP of indoor unit The loading tiom of compressor Outdoor unit FAN mode View mode stop Communicati...

Page 502: ...ressor crankcase heater by turning power breaker 3 phases single phase on before 6 hours to test operation Power ON 3 phases first and single phase If the crankcase heater is not heated CH is displayed on the check display part of outdoor unit On CH status the outdoor dose not operate Be sure to not break the compressor by a forced operation The crankcase heater uses single phase power 220V 3 Chec...

Page 503: ...reheated And the connected indoor unit address is displayed at the right of the outdoor unit PCB check display part 5 Check the system pressure by use of manifold gauge Connect the manifold gauge with the high low pressure service valve of outdoor unit Check if the high low pressure service valves are all opened Operate the system by pressing the refrigerant charge key Check the high low pressure ...

Page 504: ...ect S NET measurement instrument before the test operation as following figure Install the S NET program to the computer Connect a RS 485 converter with COM1 or COM2 port of computer Connect the communication wire connected with converter to F1 F2 terminal Connect the communication wire with TX F1 TX F2 on connecting COM1 COM2 Port Power connecter Power Outdoor Communication wire ...

Page 505: ...y 1 Cautions for Pumpdown 1 If the length of pipe is long or the outdoor temperature is high whole refrigerant may not pump down 2 If pumping down the remained refrigerant after putting some of refrigerant of the system into a empty and rechargeable refrigerant case you can perform the pumpdown smoothly If putting refrigerant into a refrigerant case must use a rechargeable case for exclusive use I...

Page 506: ...s operated observe the low pressure by using the view mode of K4 button If the first number of LED is 3 below three numbers are low pressure value Displayed down to one decimal point e g means low pressure value means the low pressure is 12 2kg cm2 g 4 If the low pressure goes down to below 2kg cm2 g lock the SVC valve on the gas side immediately and end the pumpdown operation For ending of the pu...

Page 507: ...ayed on the PCB LED If the compressor on the Main Unit is operated after pressing the button wait approximately 20 30 minutes 3 Lock the valves on the liquid side of the Sub Unit 4 Lock the valves on the liquid side of the Main Unit and observe the low pressure same as the single outdoor unit case 5 If the low pressure is lowered lock the valves on the gas side of the Main Unit and end the pumpdow...

Page 508: ...Reference Information 14 12 Samsung Electronics In case more than 2 units of outdoor unit are installed cont Sub Unit Constant Speed Outdoor Unit Main Unit Variable Outdoor Unit ...

Page 509: ...or unit to PUMP OUT 3 PUMP OUT by the K1 key of the digital outdoor unit 2 The number of pressing Display 2 3 times Main 3 times 2 4 times Sub1 4 times 2 5 times Sub2 5 times 2 6 times Sub3 6 times 4 Convert to the view mode by the K4 key 2 Low pressure part s pressure kgf cm2 2 If the number on the Display is 4020 start to lock the low pressure valve If it reaches 4000 finish it 5 Stop the outdoo...

Page 510: ... pipe or indoor unit after mixing with refrigerant during operation 2 Use the K2 Key 3 Automatic operation by the basic setting time during cooling operation 4 Use the key mode if required The number of pressing Display 7 times 7 times Sub3 Sub2 Sub1 Main Operation setup Key and Display in outdoor unit Display Key K1 K2 K3 K4 14 3 2 Oil Collection Operation ...

Page 511: ...he number of pressing Display 8 times Main unit 8 times 9 times Sub1 unit 9 times 10 times Sub2 unit 10 times 11 times Sub3 unit 11 times 12 times All unit 12 times 4 Operation Method All the EEV of the outdoor unit on the vacuum mode is opened to the maximum degree of openness and all the Solenoid Valve is waited on the open state 1 This is an operation mode to recover compressor oil that moved t...

Page 512: ...s 2 is the air conditioning and heating product must use the Bi Directional Filter Drier Use the Filter Drier specified on the below according to the outdoor unit s capacity Must use the Bi Directional Filter Drier that are stated on the above Table The installation location of the Filter Drier is the liquid pipe in front of the outdoor unit as stated the above illustration Do not install on the g...

Page 513: ...rant oil Mineral oil Suniso Combustibility None None None Toxicity None None None Ozone destruction factor ODP 0 0 0 05 Synthetic oil Ether 1 Non azeotropic mixture refrigerant mixture of two or more refrigerants having different boiling points 2 Quasi azeotropic mixture refrigerant mixture of two or more refrigerants having similar boiling points 3 The design pressure is different at each product...

Page 514: ...14 18 Samsung Electronics Reference Information Thermodynamic characteristic of R410A ...

Page 515: ...x30m b ø15 88x10m c ø9 52x10m d ø9 52x10m e ø9 52x10m f ø9 52x10m g ø6 35x10m h ø6 35x10m i ø12 70x10m j ø6 35x10m k ø6 35 x 9m Liquid side pipe ø19 05 Total pipe length m x0 27 Liquid side pipe ø15 88 Total pipe length m x0 18 A A 14 33 30x0 27 10x0 18 10x0 125 40x0 06 49x0 02 Liquid side pipe ø12 70 Total pipe length m x0 0125 Liquid side pipe ø9 52 Total pipe length m x0 06 Liquid side pipe ø6 ...

Page 516: ...ure gauge 0 1 3 8 MPa Connection port diameter 5 16 flare No oil used Working pressure 5 08 MPa Bursting pressure 25 4 MPa Connection port diameter 5 16 flare The degree of vacuum is 5torr 5 torr from atmospheric pressure Need a check valve to prevent reverse oil flow if using a conventional vacuum pump Adding a proper torque to the pipe using R410A when connect pipes to flare nuts All refrigerant...

Page 517: ...ase select Cooling or set the desired temperature lower Q It floods the floor A Place the drain hose properly When it is not placed properly the drain water would flow back flooding the floor So straighten out the drain hose for the water to be drained well Q Water drips at the drain connection service valve of the outdoor unit A When a glass bottle is taken out of the refrigerator moisture gets c...

Page 518: ... kept without drying up the inside with Ventilation mold would grow inside resulting in must So open the windows and switch on the Ventilation function to get rid of the saturated smell inside Q Whenever the air conditioner is turned on it sends out bad smells such as stale smells A It occurs generally when there are pet animals in the house Their smells stay at the same place But when the air con...

Page 519: ...outdoor unit outside A It is possible to install it at a designated place in the apartment or on the rooftop nearby But it s illegal hanging an angle iron case with the outdoor unit in it outside the apartment Also it is illegal obstructing passers by with the outdoor unit installed outside Q What can be done to install the outdoor unit facing the road because it is a commercial building A The fol...

Page 520: ...MEMO 14 24 Samsung Electronics ...

Page 521: ...MEMO Samsung Electronics 14 25 ...

Page 522: ...e Manual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd Jun 2006 Printed in Korea Code No DB98 25391A 1 ...