Field setting mode
English
Fiel
d S
etting Mode
Field Setting Value (FSV) 40**
Code 40** : User’s options for heating devices including internal backup heater and external boiler
࡙
The values in the following table are just examples for your understanding.
Main Menu &
Code
Menu
Function
Sub
Code
MODEL CODE :
AE200(260)RNW***
MODEL CODE :
MIM-E03CN / MIM-E03EN
Setting Standard
Setting Standard
Item
Step Unit
Default Min.
Max.
Default Min.
Max.
Heating
Code 40**
Heating
Heat
Pump
Heating / DHW
priority
-
-
4011 0 (DHW)
0
1
(Heating)
0 (DHW) 0
1
(Heating)
Low Outdoor Temp.
for
Heating Priority
1
ઑA
4012
0
-15
20
0
-15
20
Heating Off Temp .
1
ઑA
4013 35/45
1)*
14
35/45
1)*
35/45
1)*
14 35/45
1)*
Backup
Heater
On/Off
-
-
4021
0 (No)
0
2
0 (No)
0
2
BUH/BSH Priority
1
-
4022 2 (BSH) 0 (Both) 2 (BSH) 0 (Both) 0
2 (BSH)
Cold weather
compensation
-
-
4023 1 (Yes) 0 (No)
1
1 (Yes)
0
(No)
1
Threshold Temp.
1
ઑA
4024
0
-25
35
0
-25
35
Defrost Backup
Temp.
5
ઑA
4025
15
10
55
15
10
55
Backup
Boiler
Back-up Boiler On/Off -
-
4031
0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
Boiler Priority
-
-
4032 0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
Threshold Condition 1
ઑA
4033
-15
-20
5
-15
-20
5
Mixing
valve
Application
1
-
4041
0 (No)
0
2
0 (No)
0
2
Ɵɇθ˝ʪϩॳƟ࣍²ʪɇϩ̈͝˝࣎
1
ઑA
4042
10
5
15
10
5
15
Ɵɇθ˝ʪϩॳƟ࣍Aͱͱ̷̈͝˝࣎
1
ઑA
4043
10
5
15
10
5
15
Control factor
1
-
4044
2
1
5
2
1
5
Control interval
1
min 4045
2
1
30
2
1
30
Running Time
3
(x10)
min
4046
9
6
24
9
6
24
Inverter
Pump
Application
-
-
4051
1
0
2
1
0
2
Ɵɇθ˝ʪϩॳƟ
1
ઑA
4052
5
2
ߩ
5
2
ߩ
Control factor
1
-
4053
2
1
3
2
1
3
Addition
Function
Zone controll
1
-
4061
0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
NOTE
࡙
1)*
The value is determined according to the type of outdoor unit.
࡙
MIM-E03CN model does not support this Zone control function.