10. Installation
Electric Characteristics
1. Heat Pump / Heat Recovery (208~230V)
2. Heat Pump / Heat Recovery (460V)
•
RLA is based on AHRI 1230 Cooling Standard Condition (Indoor Temp : 26.7℃ / 80℉( DB) / 19.46℃ / 67℉ (WB),
Outdoor Temp : 35℃ / 95℉ (DB))
•
Voltage Tolerance is ± 10%
•
Maximum allowable voltage between phases is 2%
•
Refer to module combination table for independent units information
•
Symbols :
-
RLA : Rated Load Ampere
-
FLA : Full Load Ampere
-
MCA : Minimum Circuit Ampere (A)
-
MOP : Maximum Overcurrent Protective Device (A)
Electrical wiring work
NOTE
6Ton
AM072BXVTF*
60 208~230
18
18
4.2
4.2
50
60
-
-
-
-
-
-
-
-
-
-
-
-
8Ton
AM096BXVTF*
60 208~230
22
22
4.2
4.2
62
70
-
-
-
-
-
-
-
-
-
-
-
-
10Ton
AM120BXVTF*
60 208~230
28
28
4.2
4.2
76
90
-
-
-
-
-
-
-
-
-
-
-
-
12Ton
AM144BXVTF*
60 208~230
18
18
4.2
4.2
50
60
18
18
4.2
4.2
50
60
-
-
-
-
-
-
14Ton
AM168BXVTF*
60 208~230
18
18
4.2
4.2
50
60
22
22
4.2
4.2
62
70
-
-
-
-
-
-
16Ton
AM192BXVTF*
1
60 208~230
22
22
4.2
4.2
62
70
22
22
4.2
4.2
62
70
-
-
-
-
-
-
18Ton
AM216BXVTF*
1
60 208~230
18
18
4.2
4.2
50
60
18
18
4.2
4.2
50
60
18
18
4.2
4.2
50
60
20Ton AM240BXVTF*
1
60 208~230
18
18
4.2
4.2
50
60
18
18
4.2
4.2
50
60
22
22
4.2
4.2
62
70
22Ton AM264BXVTF*
60 208~230
18
18
4.2
4.2
50
60
18
18
4.2
4.2
50
60
28
28
4.2
4.2
76
90
24Ton AM288BXVTF*
60 208~230
18
18
4.2
4.2
50
60
22
22
4.2
4.2
62
70
28
28
4.2
4.2
76
90
Module #1
Module #2
Nom.
Units
RLA
FLA
Power Supply
RLA
FLA
Power Supply
RLA
FLA
Power Supply
Ton
Model
Hz
Volts Comp1Comp2 FAN1 FAN2 MCA MOP Comp1 Comp2 FAN1 FAN2 MCA MOP Comp1Comp2 FAN1 FAN2 MCA MOP
6Ton
AM072BXVTJ*
60
460
9.2
9.2
2.1
2.1
25
30
-
-
-
-
-
-
-
-
-
-
-
-
8Ton
AM096BXVTJ*
60
460
11.0
11.0
2.1
2.1
31
35
-
-
-
-
-
-
-
-
-
-
-
-
10Ton
AM120BXVTJ*
60
460
14.0
14.0
2.1
2.1
38
45
-
-
-
-
-
-
-
-
-
-
-
-
12Ton
AM144BXVTJ*
60
460
9.2
9.2
2.1
2.1
25
30
9.2
2.1
2.1
25
30
-
-
-
-
-
-
14Ton
AM168BXVTJ*
60
460
9.2
9.2
2.1
2.1
25
30
11.0
2.1
2.1
31
35
-
-
-
-
-
-
16Ton
AM192BXVTJ*
1
60
460
11.0
11.0
2.1
2.1
31
35
11.0
2.1
2.1
31
35
-
-
-
-
-
-
18Ton
AM216BXVTJ*
1
60
460
9.2
9.2
2.1
2.1
25
3
0
9.2
2.1
2.1
25
30
9.2
9.2
2.1
2.1
25
30
20Ton
AM240BXVTJ*
1
60
460
9.2
9.2
2.1
2.1
25
30
9.2
2.1
2.1
25
30
11
11
2.1
2.1
31
35
22Ton
AM264BXVTJ*
60
460
9.2
9.2
2.1
2.1
25
30
9.2
2.1
2.1
25
30
14
14
2.1
2.1
38
45
24Ton
AM288BXVTJ*
60
460
9.2
9.2
2.1
2.1
25
30
11.0
2.1
2.1
31
35
14
14
2.1
2.1
38
45
Module #1
Module #2
Nom.
Units
RLA
FLA
Power Supply
RLA
FLA
Power Supply
RLA
FLA
Power Supply
Ton
Model
Hz
Volts Comp1Comp2 FAN1 FAN2 MCA MOP Comp1 Comp2 FAN1 FAN2 MCA MOP Comp1Comp2 FAN1 FAN2 MCA MOP
Module #
3
Module #
3
9.2
11.0
11.0
9.2
9.2
9.2
11.0