14
PRODUCT SPECIFICATIONS
Items
Specification
Models
RH25H5611* / RH25H 5613*
Components for Fr
eezer
Compressor
Model
MKV190CL2B/SM1
MKV190GL2J/SM1
Starting type
BLDC
Oil Charge
FREOL
α
15
Evaporator
Freezer
SPLIT FIN TYPE
Refrigerator
SPLIT FIN TYPE
Condenser
Forced and natural convection type
Dryer
Molecular sieve XH-9
Capillary tube(Dia×Length)
0.033 ”×130 ”
Refrigerant
R134a
Room T
emperatur
e Sensor
Components
Fr
eezer
Model
Temperature
Selection
ON( ˚F/ ˚C )
OFF( ˚F/ ˚C )
THERMISTOR
(F-SENSOR)
502AT
-8 ˚F (-23˚C)
-5˚F (-21˚C)
-11˚F (-24 ˚C)
0 ˚F (-18˚C)
3˚F (-16˚C)
-3˚F (-19 ˚C)
5 ˚F (-15˚C)
8˚F (-13˚C)
3˚F (-16 ˚C)
Refrigerator
Model
Temperature
Selection
ON( ˚F/ ˚C )
OFF( ˚F/ ˚C)
THERMISTOR
(R-SENSOR)
502AT
34 ˚F (1˚C)
38˚F (3˚C)
30˚F (-1 ˚C)
37 ˚F (3˚C)
41˚F (5˚C)
33˚F (1 ˚C)
44 ˚F (7˚C)
48˚F (9˚C)
40˚F (5 ˚C)
Defr
ost Related Components
Defr
ost Cycle
First Defrost Cycle (Concurrent
defrost of F and R)
6hr ± 10min (Comp on integation)
Defrost Cycle(FRE)
12~48hrs (vary according to the conditions used)
Pause time
10 ± 2 min
Defr
ost Sensor
F Defrost-
Sensor
Model
THERMISTOR (502AT)
SPEC
5.0
㏀
at 25˚C
R Defrost-
Sensor
Model
THERMISTOR (502AT)
SPEC
5.0
㏀
at 25˚C
Bimetal
Rated
250V/60Hz, 10A
Operating temperature
Off : 60± 5˚C, On : 40± 5˚C
Summary of Contents for LS3165H52HR
Page 52: ...54 TROUBLESHOOTING Diode Voltage of IPM ...
Page 69: ...72 PCB DIAGRAM 6 3 Connector Arrangement Main Board ...
Page 71: ...69 5 WIRING DIAGRAM ...
Page 72: ...74 7 1 Block Diagram 7 SCHEMATIC DIAGRAM ...
Page 73: ...75 SCHEMATIC DIAGRAM 7 2 Block Diagram INVERTER PBA DC 13 2V 5V ...
Page 76: ...EXPLODED VIEW 1 FREEZER ...
Page 78: ...15 EXPLODED VIEW 2 FRIDGE 16 ...
Page 83: ...1 7 1 8 4 5 7 3 8 2 8 3 11 10 12 EXPLODED VIEW 4 DOOR FRE 4 6 9 3 13 ...
Page 85: ...3 4 5 1 3 2 2 3 3 3 4 3 4 1 3 1 6 EXPLODED VIEW 5 DOOR REF IN ...
Page 87: ...3 3 1 2 1 1 1 4 1 5 1 6 1 7 4 EXPLODED VIEW 6 DOOR REF OUT 1 ...