background image

26

Gas Conversion

■  Be careful, the operations and adjustments to be carried out when converting 

from one gas to another.

■  All work must be carried out by a qualified technician.

■  Before you begin, turn off the gas and electricity supply to the appliance.

Change the injector of the burners.

1

Remove the pan support, Burner lid and Flame spreader.

Unscrew the injector using a 7mm box spanner and replace it with 

the stipulated injector for new gas supply. ( see table 1. Page 27.)
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten the 

injector in place.

Adjusting of the taps of the cooking hob burners for  

reduced consumption

2

 Turn the taps down to minimum.

 Remove the control handles from taps.

  Adjusting the by-pass screw.

    -  For converting G20 into G30 or G31, the screw must 

be screwed down fully tight.

    -  At this stage, light up the burners and turn the 

control handles from max position to minimum 

position to check flame stability.

    -  For converting G30 or G31 into G20, please contact 

“After-Sales Service”.

 Replace the control handles on the taps.

Injector

Control handle

Tap
Sealing ring

Tap

by-pass screw

 

■  Do not dismantle the tap shaft : in the event of a malfunction, change the whole tap.

■  Before placing the burners back on the top place, make sure that the injector is 

not blocked.

■  A full operational test and a test for possible leakages must be carried out after 

gas conversion. (such as soap water or gas detector) 

■  After completing conversion, a qualified technician or installer has to mark “V”  

on the right gas category 

to match with the setting 

in rating plate. 

Remove the previous 

setting “V” mark.

GN642HFGD

S/N: A36579MZ400007A

G20/20mbar

220-240V 50/60Hz, Pmax 1W

∑Qn  Q20: 7.5kW  G30: 521g/h  G31: 503g/h

  G20-20mbar           G30/29mbar           G31/37mbar           

GB Cat.: ll 2H3+

0063

27

Burner Features

Nominal heat input and flow rates see below at 15˚C at 1,013 mbar. 

(Table 1)

COUN-

TRY

TYPE OF 

GAS

BURNER

Triple-Crown

Rapid

Semi-rapid

Auxiliary

Total

POSITION

Max Min Max Min Max Min Max Min

GB,IT

FR,HU

BE,LT

NL,PT

ES,CZ

SK

G-30

BUTANE

29 mbar

Injector make  

(1/100 mm)

88

85

65

50

-

Nominal heat input 

(Kw)

3.0 1.25 3.0

0.74 1,75 0.43

1.0

0.37

7.5

Nominal flow rates  

(g/h)

211.1 35

211

53

120

31

71

25

PL

G-30

BUTANE

37 mbar

Injector make  

(1/100 mm)

80

80

62

47

-

Nominal heat input 

(Kw)

3.0 1.28 3.0

0.81 1,75 0.47

1.0

0.38

7.5

Nominal flow rates  

(g/h)

203.4 35

203

58

125

33

71

25

GB,IT

FR,BE

LT,PT

ES,CZ

SK

G-31

PROPANE

37 mbar

Injector make  

(1/100 mm)

88

85

65

50

-

Nominal heat input 

(Kw)

3.0 1.25 3.0

0.71 1,75 0.41

1.0

0.33

7.5

Nominal flow rates 

(g/h)

199.4 45

199

49

118

28

68

23

GB,IT

FR,BE

LT,PT

PL,ES

CZ,SK

G-20

NATURAL

20 mbar

Injector make  

(1/100 mm)

130

119

97

72

-

Nominal heat rating 

(Kw)

3.0 1.25 3.0

1.14 1,75 0.63

1.0

0.45

7.5

Nominal flow rates  

(L/h)

271 118 271

79

166

54

91

30

HU

G-20

NATURAL

25 mbar

Injector make  

(1/100 mm)

125

110

91

68

-

Nominal heat input 

(Kw)

3.0 1.31 3.0

1.33 1,75 0.57

1.0

0.49

7.5

Nominal flow rates  

(L/h)

271 124 271

79

166

54

91

30

Burner

Calibrated orifice 1/100mm

Auxiliary

31

Semi-rapid

34

Rapid

43

Triple-Crown

60

- Aeration adjustment none

Summary of Contents for GN642FFGD

Page 1: ...GB P N 50551 40110 Installation and User Manual GN642HFGD GN642FFGD Built In Hotplate GB ...

Page 2: ...untries other than those marked on the appliance The manufacturer also reserves the right to make any modifications to the products as may be considered necessary or useful also in the interests of the user without jeopardizing the main functional and safety feafures of the products themselves 3 Contents Preface 2 Safety Warning 4 10 Safety Warning 4 Installation 5 Child and People Safety 6 During ...

Page 3: ...and only used in a well ventilated space Installation Warning Do not install this appliance on any type of marine vessel or Leisure Accommodation Vehicle The gas pipe and electrical cable must be installed in such a way that they do not touch any parts or the appliance Prior to installation ensure that the gas and electrical supply complies with the type stated on the rating plate This appliance s...

Page 4: ...ing Use The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed Ensure that the kitchen is well ventilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor hood The heating and cooking surfaces of the appliance become hot when they are in use take all due precautions Never leave the ap...

Page 5: ...ls off before removing cookware Carefully watch foods being fried at a high flame setting Always heat fat slowly and watch as it heats Foods for frying should be as dry as possible Frost on frozen foods or moisture on fresh foods can cause hot fat to bubble up and over the sides of the pan Never try to move a pan of hot fat especially a deep fat fryer Wait until the fat is cool Perishable food plas...

Page 6: ...brasive or caustic cleaning things Warning Cleaning Service Before attempting to clean the appliance it should be disconnected from the mains and cool You should not use a steam jet or any other high pressure cleaning equipment to clean the appliance This appliance should only be repaired or serviced by an authorised Service Engineer and only genuine approved spare parts should be used Caution Env...

Page 7: ... next to the control handle will indicate which burner it operates If the igniters are dirty this makes the burner harder to light so you should keep them as clean as possible Do this with a small brush and make sure that the ignition device is not hit or knocked violently The flame supervision device shall not be operated for more than 15s If after 15s the burner has not lit stop operating the dev...

Page 8: ... them that they increase the temperature in this area and may cause damage Always place the cookware right over the burners not to one side Never place cookware directly on top of the burner Place the cookware on top of the pan support Do not use excessive weight and do not hit the hob with heavy objects Handle cookware carefully when they are on the burner It is not permitted to use roasting pans...

Page 9: ...tal Brush Acidic Alkali Detergent Thinner Benzene Edible Oil Acidic Alkali Detergent Soft Clothing Sponge Brush neutral Detergent Nylon Brush Edible Oil Abrasive Metal Brush Acidic Alkali Detergent Thinner Benzene Neutral Detergent Soft Clothing Sponge Brush neutral Detergent Nylon Brush Edible Oil Abrasive Metal Brush Acidic Alkali Detergent Thinner Benzene Abrasive Thinner Benzene Nylon Brush Th...

Page 10: ...ng Electronics Magyar Rt Szépvölgyi Business Park 1037 Budapest Szépvölgyi út 35 37 ITALIA 800 SAMSUNG 7267864 www samsung com it 02 92141801 Samsung Electronics Italia S p A Via C Donat Cattin 5 20063 Cernusco Sul Naviglio MI LUXEMBURG 02 261 03 710 www samsung lu N A Samsung Electronics Benelux B V Medialaan 50 1800 Vilvoorde Belgium NETHERLANDS 0900 20 200 88 0 10 Min www samsung nl N A Samsung...

Page 11: ...ammable material Both the strati fied surfacing and the glue used to secure it should be heat resistant to prevent deterioration Turn on appliance tap and light each burners Check for a clear blue flame without yellow tipping If burners shows any abnormalties check the following Burner lid on correctly Flame spreader positioned correctly Burner vertically aligned with injector nipple A full operatio...

Page 12: ...D ABOVE Positioning 40mm 150mm MAX a 23 1 Remove the pan support the burner lid and flame spreader and carefully turn the appliance upside down and place it on a cushioned mat Take care that the Ignition devices and flame supervision devices are not damaged in this operation 2 Apply the sealing strip provided around the edge of the appliance 3 Do not leave a gap in the sealing agent or overlap the t...

Page 13: ...ety you must choose from the three following connection option For the user s safety we advise the connection to be made with a rigid pipe if this is possible using a flexible undulated metal tube with scerw on connectors maximum length 2meters Fig A For an existing installation where it is not possible to fit a reinforced braided flexible gas hose the connection can be made with a flexible gas hose m...

Page 14: ... water or gas detector After completing conversion a qualified technician or installer has to mark V on the right gas category to match with the setting in rating plate Remove the previous setting V mark GN642HFGD S N A36579MZ400007A G20 20mbar 220 240V 50 60Hz Pmax 1W Qn Q20 7 5kW G30 521g h G31 503g h G20 20mbar G30 29mbar G31 37mbar GB Cat ll 2H3 0063 27 Burner Features Nominal heat input and flo...

Reviews: