Step 1
① Check if the Conv. Fan motor is connected properly.
② Check for any abnormal noise during Conv. Mode operation.
③ Check if Blade is rotating properly during Conv. Mode operation.
④ Check if the Assy Cover Casing Set Screw is tightened properly.
⑤ Check if Wire harness is connected properly without any issues.
Step 2
① Disassemble the Assy casing and check the Blade for deformation and
interference with nearby parts.
② Check the input voltage at Conv. Fan motor (normal : 120VAC).
→ If voltage value isn’t normal, replace the Main PCB.
③ Check the resistance between the Conv. Fan motor terminals.
(normal Resistance = 20~30Ω)
Check Point
“Convection operation and abnormal noise” inspection.
Tip 6-4. Convection Operation Inspection