background image

Table des matières

INSTALLATION

Emplacement

. . . .

 

. . . . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . .

 

2

3

 

Configuration des ports

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

 

Installer la conduite de récupération desfluides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

5

 

Installation des conduits. 

. . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . . . . .

 

. . . . . . . .

.

. . .

 

. . . . . . . . 25

ÉQUILIBRAGE DU DÉBIT D'AIR 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

EXEMPLES D'INSTALLATION

Système entièrement dédié

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

 

Système partiellement dédidé (connexion directe)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

7

 

Système partiellement dédidé (connexion indirecte) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

8

 

Installation simplifié 

. . . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . . . . . . . . . .

.

. . . . .

.

.

 

. . . . . . . . . . .

2

8

MODES D'OPÉRATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

9

 

Configurer la vitesse 

. . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . . . . .

 

. . . . . . . . . . . . .

 

. . . . . . . . . . . . . . . . . 30

SYSTÈMES DE CONTRÔLE À BASSESION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

1

ENTRETIEN

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2

CONNEXIONS ÉLECTRIQUES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

3

TEST DE VÉRIFICATION DE L'INSTALLATION 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

4

24

  AVERTISSEMENT

Эʪθϩ̈ϑϑʪ͔ʪ͝ϩʀͱ͝ʀʪθ͝ɇ͝ϩ̷ɇΧθͱΧͱϑ̈ϩ̈ͱ͝एߠߟʒʪ̷ࣴmϩɇϩʒʪ̷ɇAɇ̷̈˙ͱθ̈͝ʪࣔmϩɇϩϑࣞƸ̈͝ϑЇ̈͝αЇʪ͔ʪ͝ϩࣕ

AʪϩɇΧΧɇθʪ̷̈ʀͱ͝ϩ̈ʪ͝ϩʒʪϑΧθͱʒЇ̈ϩϑʀ˵͔̈̈αЇʪϑʀͱ͝͝Їϑʒʪ̷ࣴmϩɇϩʒʪ̷ɇAɇ̷̈˙ͱθ̈͝ʪΧͱЇθʀɇЇϑʪθ̷ʪʀɇ͝ʀʪθʪϩʒʪϑɇ͝ͱ͔ɇ̷̈ʪϑ

 

ʀͱ͝˝ʭ̈͝ϩɇ̷ʪϑͱЇʒʪϑʪ˙˙ʪϩϑ͝ͱʀ̈˙ϑϑЇθ̷ɇθʪΧθͱʒЇʀϩ̈ͱ͝࢒

Summary of Contents for Fresh Access AN035NSEDAV/AA

Page 1: ...ate provincial requirements or in the absence of such requirements with the current edition of the National Building Code and or ASHRAE s Good Engineering Practices Samsung HVAC reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www Samsung...

Page 2: ...n lack of operation or partial failure may result in the backdrafting or improper functioning of vented combustion equipment Products are designed and manufactured to provide reliable performance but they are not guaranteed to be 100 free of defects Even reliable products will experience occasional failures and this possibility should be recognized by the user If these products are used in a life ...

Page 3: ...ons 8 Partially Dedicated Systems indirect connections 9 Simplified Installation 9 MODES OF OPERATION 10 Speed Setting 11 LOW VOLTAGE CONTROL SYSTEM 12 MAINTENANCE 13 WIRING DIAGRAM 14 INSTALLATION VERIFICATION TEST 18 3 WARNING State of California Proposition 65 Warning US only This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive...

Page 4: ...ntended Unit may need to be protected with an insulated shelter built on site Connecting appliances to the ERV It is not recommended including clothes dryer kitchen exhaust hoods combustion venting central vacuum system These appliances may cause lint dust or grease to collect in the ERV damaging the unit Connecting any of these type of appliances to the ERV will invalidate your warranty A B C D E...

Page 5: ...Factory Setting Unit may be easily reversed in field Factory Setting Unit may be easily reversed in field Port configuration The unit has access doors on the front and back Also the main control panel may be moved from front to back allowing for ducting layout AN035NSEDAV AA and AN075NSEDAV AA 5 ...

Page 6: ...n integral single piece of insulated wrap with vapor barrier should be used to connect the ERV to the weatherhoods Insulated flex duct may be used in moderation if sized and installed properly Consult local codes A minimum R value of insulation should be equal to 4 RSI 0 75 consult local codes All ducts should be sealed using a good bead of high quality caulking preferably acoustical sealant and a...

Page 7: ...t and have as few bends or elbows as possible Forty five degree are preferred to 90o elbows Use Y tees instead of mitered tee whenever possible All duct joints must be fastened with screws or duct sealant and wrapped with a quality duct tape to prevent leakage Aluminum foil duct tape is recommended Supply air ducting In buildings without a forced air HVAC systems fresh air should be supplied to al...

Page 8: ... work number of fittings used in duct work duct heater etc Fully Dedicated System Stale air drawn from areas of contamination Fresh air supplied to main areas ERV airflow should be balanced External heating or cooling coil may be needed if air is not able to mix comfortably SUPPLY IN EXHAUST OUT ERV UNIT SUPPLY DUCT RETURN AIR DUCT AIR HANDLER UNIT SUPPLY IN BALANCING DAMPERS SUPPLY IN EXHAUST OUT...

Page 9: ...uct work duct heater etc SUPPLY IN EXHAUST OUT ERV UNIT RETURN AIR DUCT AIR HANDLER UNIT SUPPLY IN BALANCING DAMPERS SUPPLY IN EXHAUST OUT HRV UNIT SUPPLY DUCT EXHAUST AIR TO HRV UNIT 12 BREATHER SPACE CEILING RETURN AIR PLENUM AIR HANDLER UNIT SUPPLY IN BALANCING DAMPERS Simplified Installation Stale air drawn from return of air handler Fresh air supplied to return of air handler further down str...

Page 10: ... mode is recommended since pollutants are slowly but constantly being generated in a building 2 Intermittent Standby Mode The system is always on standby and operates at high speed when activated by an optional remote control required Standby should be selected if the user wishes to stop the unit from continuous exchange 3 Defrost by evacuation A preset defrost sequence is activated at an outdoor ...

Page 11: ...net The voltage selection for low reduced speed of the unit is done via jumpers shown in the illustration below The default setting 75V Setting low speed AN120NSEDAV AA Low 75V Factory Default Low 90V Configurable speed control for low reduced speed CAUTION MAKE SURE THE POWER TO THE UNIT IS DISCONNECTED BEFORE MAKING ANY CHANGES 11 ...

Page 12: ...ht touchscreen LCD ECO mode selects the best operating mode and speed for the season minimizing energy use associated with ventilation Set preferred indoor relative humidity range and ventilation mode for day and night conditions No battery to replace all programmed settings are retained during power outage Maintenance reminder indicator Error code messages reduce troubleshooting time 1 Ensure tha...

Page 13: ... 4 6mm followed by the other side c Mount the top flange of the core guide into the top channel approximately 1 4 6mm d With all four corners in place and the core straight and even push hard in the center of the core until the core stops on the back of the cabinet Maintenance The motor The motors are factory balanced and lubricated for life They require no maintenance The unit The inside of the u...

Page 14: ...SYSTEM RV CTRL 24VAC Standard Furnace Interlock Wiring W R G C Y W R G Y THERMOSTAT TERMINALS FURNACE 24 VOLT TERMINAL BLOCK FOUR WIRE TWO WIRE heating only TWO WIRE COOLING SYSTEM SHUTOFF DAMPER SHUTOFF DAMPER RV CTRL 24VAC Standard Furnace Interlock Wiring w Damper 1 3 COIL CONTROL RELAY TERMINAL LABELING MAY VARY R C ...

Page 15: ... heating only TWO WIRE COOLING SYSTEM RV CTRL 24VAC Alternate Furnace Interlock Wiring w Damper W R G C Y W R G Y THERMOSTAT TERMINALS FURNACE 24 VOLT TERMINAL BLOCK FOUR WIRE TWO WIRE heating only TWO WIRE COOLING SYSTEM SHUTOFF DAMPER SHUTOFF DAMPER RV CTRL 24VAC NC COIL CONTROL RELAY TERMINAL LABELING MAY VARY R C NO COM ...

Page 16: ...Wiring Diagram AN035NSEDAV AA 14 AN035NSEDAV AA 24VAC field provided ...

Page 17: ...Wiring Diagram AN075NSEDAV AA 15 AN075NSEDAV AA 24VAC field provided ...

Page 18: ...Wiring Diagram AN120NSEDAV AA 16 AN120NSEDAV AA 24VAC field provided ...

Page 19: ...me newer furnaces and older thermostats energizing the R and G terminal at the furnace has the effect of energizing the Y at the thermostat and thereby turning on the cooling system If you identify this type of thermostat you must use the Alternate Furnace Interlock Wiring ATTENTION Do not to connect the ERV unit to a furnace if shutoff dampers are installed as it will cause damage to the furnace ...

Page 20: ...duced speed Supply fan runs in LOW Reduced speed 5 HIGH Normal speed Set fans speed selector switch HIGH Normal speed The following should occur Exhaust fan ramps up to HIGH Normal speed Supply fan ramps up to HIGH Normal speed 6 Test completion Set fan speed selector switch to desired setting Installation Verification test is complete With external control 1 Start up Apply power to unit Unit shou...

Page 21: ...r any other circumstances outside Fresh Access sTM control Inappropriate installation or maintenance may result in the cancellation of the warranty Any unauthorized work will result in the cancellation of the warranty Fresh AccessTM is not responsible for any incidental or consequential damages incurred in the use of the ventilation system Fresh AccessTM is not responsible for providing an authori...

Page 22: ...fective in materials and or factory workmanship under normal application installation use and service conditions This Limited Warranty shall apply to the System sold by SAMSUNG HVAC in the continental United States Alaska Hawaii U S Territories Canada the Provinces of Canada and Bermuda and extend only to the original end use purchaser and owner s of location on which the System is originally inst...

Page 23: ...21 ...

Page 24: ...faut de telles exigences conformément à l édition actuelle du Code national du bâtiment du Canada ou aux méthodes d ingénierie appropriées de l ASHRAE Fresh AccessTM reserves the right to make technical changes For updated documentation please refer to www SamsungHVAC com Fresh AccessTM se réserve le droit de faire des changements techniques Pour de la documentation à jour s il vous plaît se référ...

Page 25: ...n fonctionnement normal le manque de fonctionnement ou une panne partielle pourrait entraîner un refoulement ou un mauvais fonctionnement des appareils de combustion ventilés Les produits sont conçus et fabriqués pour fournir une performance fiable mais ils ne sont pas garantis à 100 sans défaut Même les produis ont des pannes occasionnelles et cette possibilité devrait être reconnue par l utilisa...

Page 26: ...stème partiellement dédidé connexion indirecte 28 Installation simplifié 28 MODES D OPÉRATION 29 Configurer la vitesse 30 SYSTÈMES DE CONTRÔLE À BASSESION 31 ENTRETIEN 32 CONNEXIONS ÉLECTRIQUES 33 TEST DE VÉRIFICATION DE L INSTALLATION 34 24 AVERTISSEMENT Эʪθϩ ϑϑʪ ʪ ϩ ʀͱ ʀʪθ ɇ ϩ ɇ ΧθͱΧͱϑ ϩ ͱ एߠߟ ʒʪ ࣴmϩɇϩ ʒʪ ɇ Aɇ ͱθ ʪ ࣔmϩɇϩϑࣞƸ ϑ Ї αЇʪ ʪ ϩࣕ Aʪϩ ɇΧΧɇθʪ ʀͱ ϩ ʪ ϩ ʒʪϑ ΧθͱʒЇ ϩϑ ʀ αЇʪϑ ʀͱ Їϑ ʒʪ ࣴmϩɇϩ ʒʪ ɇ...

Page 27: ...i fonctionnera comme prévu On pourra protéger l appareil avec un abri isolé bâti sur place On ne recommande pas de brancher d autre appareils au ventilateur récupérateur d énergie y compris les sécheuses les hottes de cuisine les appareils d évacuation des gaz de combustion les systèmes centraux d aspiration Ces appareils peuvent produire de la poussière des peluches ou de la graisse qui peuvent s...

Page 28: ...ère afin de faciliter la configuration du système de gaines AN035NSEDAV AA AN075NSEDAV AA Côté frois Côté frois Côté chaud AN120NSEDAV AA Côté chaud Côté chaud Côté frois Côté frois Côté chaud Réglage en usine L appareil peut être facilement inversé sur les lieux d installation Réglage en usine L appareil peut être facilement inversé sur les lieux d installation 26 ...

Page 29: ...rale l enveloppe isolée pare vapeur pour raccorder le ventilateur récupérateur de chaleur aux capots On peut utiliser des gaines flexibles isolées avec modération si celles ci sont dimensionnées et installées correctement Se référer aux codes locaux Une valeur minimum de calibre R d isolation doit être égale à 4 RSI 0 75 consulter les codes locaux On doit sceller toutes les gaines à l aide d un bo...

Page 30: ...ns le système de gaines on doit tenir ces dernières courtes et exemptes du plus de coudes possible Les coudes à 45 degrés sont préférables à ceux à angle droit Utiliser des raccords en Y plutôt que des T lorsque cela est possible On doit fixer tous les joints de gaines à l aide de vis ou de scellant à gaine et les envelopper d un ruban à conduits pour éviter les fuites On recommande le ruban à con...

Page 31: ...ièrement dédié Air vicié prélevé dans les zones de contamination Air frais fourni aux zones principales Le débit d air du VRE doit être équilibré Un serpentin de chauffage ou de refroidissement externe peut être nécessaire si l air ne peut se mélanger de manière à être confortable APPORT ÉVACUATION VENTILATEUR RÉCUPÉRATEUR D ÉNERGIE GAINE D ALIMENTATION GAINE DE RETOUR D AIR AIR D ÉVACUATION VERS ...

Page 32: ...UATION VENTILATEUR RÉCUPÉRATEUR D ÉNERGIE GAINE D AIR DE REPRISE APPAREIL DE TRAITEMENT DE L AIR APPORT ENTRANT REGISTE D ÉQUILIBRAGE APPORT ÉVACUATION VENTILATEUR RÉCUPÉRATEUR D ÉNERGIE GAINE D ALIMENTATION AIR D ÉVACUATION DU VRE ESPACE DE 12 PO PLÉNUM D AIR DE REPRISE AU PLAFOND APPAREIL DE TRAITEMENT DE L AIR APPORT REGISTRE D ÉQUILIBRAGE Installation simplifiée L air vicié est prélevé à parti...

Page 33: ...mais constamment générés dans un bâtiment 2 Mode intermittent en attente Le système est toujours en mode attente et fonctionne à haute vitesse lorsqu on l actionne à l aide d une commande à distance optionnelle nécessaire on ne doit choisir le mode en attente Standby que si l usager souhaite arrêter l échange en continu sur l appareil 3 Dégivrage par évacuation Une séquence de dégivrage préréglée ...

Page 34: ...a tension pour la basse vitesse réduite de l unité se fait via les cavaliers indiqués dans l illustration ci dessous Le réglage par défaut 75V Configurer la vitesse AN120NSEDAV AA Min 75V Défautde fabrication Min 90V Configurations de vitesse pour la basse vitesse réduite AVERTISSEMENT ASSUREZ VOUS QUE L ALIMENTATION DE L UNITÉ EST DÉCONNECTÉE AVANT DE FAIRE DES CHANGEMENTS 32 ...

Page 35: ...ne le meilleur mode de fonctionnement pour la saison en réduisant les coûts d énergie grâce au mode de ventilation Gamme d humidité relative réglable et le mode de ventilation pour les conditions de jour et de nuit Indicateur rappel d entretient Messages d erreur de code réduit le temps de dépannage 1 Assurez vous que l appareil n est pas branché lors de la connexion des contrôles 2 Le mode de rec...

Page 36: ...ite du rail du noyau à environ 1 4 po 6 mm suivi de celle de l autre côté c Installer la bride supérieure du rail du noyau dans le passage supérieur à environ 1 4 po 6 mm d Une fois les quatre coins en place et le noyau droit et équilibré pousser dans le centre du noyau jusqu à ce que celui ci atteigne l arrière du caisson Entretien Moteur Les moteurs sont équilibrés en usine et lubrifiés à vie Il...

Page 37: ...Connexions électriques AN035NSEDAV AA 35 AN035NSEDAV AA 24VAC field provided ...

Page 38: ...Connexions électriques AN075NSEDAV AA 36 AN075NSEDAV AA 24VAC field provided ...

Page 39: ...Connexions électriques AN120NSEDAV AA 37 AN120NSEDAV AA 24VAC field provided ...

Page 40: ...O WIRE COOLING SYSTEM RV CTRL 24VAC Standard Furnace Interlock Wiring W R G C Y W R G Y THERMOSTAT TERMINALS FURNACE 24 VOLT TERMINAL BLOCK FOUR WIRE TWO WIRE heating only TWO WIRE COOLING SYSTEM SHUTOFF DAMPER SHUTOFF DAMPER RV CTRL 24VAC Standard Furnace Interlock Wiring w Damper 1 3 COIL CONTROL RELAY TERMINAL LABELING MAY VARY R C ...

Page 41: ...eating only TWO WIRE COOLING SYSTEM RV CTRL 24VAC Alternate Furnace Interlock Wiring w Damper W R G C Y W R G Y THERMOSTAT TERMINALS FURNACE 24 VOLT TERMINAL BLOCK FOUR WIRE TWO WIRE heating only TWO WIRE COOLING SYSTEM SHUTOFF DAMPER SHUTOFF DAMPER RV CTRL 24VAC NC COIL CONTROL RELAY TERMINAL LABELING MAY VARY R C NO COM 39 ...

Page 42: ...duit vitesse Ventilateur d approvisionnement fonctionne à Basse Réduit vitesse 5 HAUTE Normale vitesse Réglez le sélecteur de vitesse du ventilateur à Haute vitesse Normal Les éléments suivants devraient se produire Ventilateur d évacuation augmente jusqu à Haute vitesse Normal Ventilateur d approvisionnement augmente jusqu à Haute vitesse Normal 6 Fin du test Réglez le sélecteur de vitesse à la p...

Page 43: ... manutention inadéquate des erreurs d application des cas fortuits ou de toute autre circonstance hors du contrôle de Fresh AccessTM Une mauvaise installation ou un entretien inappropriée pourrait annuler la garantie Tout travail non autorisé réalisé sur l appareil annulera la garantie Fresh AccessTM n est pas responsable des dommages indirects entraînés par l utilisation du système de ventilation...

Page 44: ......

Page 45: ... make technical changes For updated documentation please refer to www SamsungHVAC com Fresh AccessTM se réserve le droit de faire des changements techniques Pour de la documentation à jour s il vous plaît se référer au www SamsungHVAC com ...

Reviews: