04_
safety information
• If the freezer is damaged by water, pull out
the power plug and contact your Samsung
Electronics service center.
CAUTION SIGNS FOR
CLEANING
• Do not directly spray water inside or outside
the freezer.
- There is a risk of fire or electric shock.
• Do not spray inflammable gas near the freezer.
- There is a risk of explosion or fire.
• Remove any foreign matter or dust from
the power plug pins. But do not use a wet or
damp cloth when cleaning the plug, remove any
foreign material or dust from the power plug pins.
- Otherwise there is a risk of fire or electric shock.
• Do not sp
ray cleaning products directly on the
display.
- Printed letters on the display may come off.
• Unplug the freezer before cleaning and
making repairs.
SEVERE WARNING SIGNS
FOR DISPOSAL
• When disposing of this or other freezers,
remove the door/door seals, door
latch so that small children or animals cannot
become trapped inside. Children should be
supervised to ensure that they do not play with the
appliance.
• Please dispose of the packaging material for this
product in an environmentally friendly manner.
• Leave the shelves in place so that children may not
easily climb inside. Ensure that none of the pipes
on the back of the appliance are damaged prior to
disposal.
• R600a or R134a is used as a refrigerant. Check
the compressor label on the rear of the appliance
or the rating label inside the freezer to see which
refrigerant is used for your freezer. When this
product contains flammable gas (Refrigerant
R600a), contact your local authority in regard to
safe disposal of this product. Cyclopentane is used
as a insulation blowing gas. The gases in insulation
material require special disposal procedure.
Please contact your local authorities in regard to
the environmentally safe disposal of this product.
Ensure that none of the pipes on the back of the
appliances are damaged prior to disposal. The
pipes shall be broke in the open space.
• If the appliance contains iso-butane refrigerant
(R600a), a natural gas with high environmental
compatibility that is, however, also combustible.
When transporting and installing the appliance,
care should be taken to ensure that no parts of the
refrigerating circuit are damaged.
• Refrigerant squirting out of the pipes could ignite
or cause an eye injury. If a leak is detected, avoid
any naked flames or potential sources of ignition
and air the room in which the appliance is standing
for several minutes.
• In order to avoid the creation of a flammable
gas-air mixture if a leak in the refrigerating
circuit occurs, the size of the room in which the
appliance may be sited depends on the amount of
refrigerant used.
Never start up an appliance showing any signs of
damage. If in doubt, consult your dealer.
The room must be 1m³ in size for every 8g of
R600a refrigerant inside the appliance. The
amount of refrigerant in your particular appliance
is shown on the identification plate inside the
appliance.
WARNING
CAUTION
DA99-01951G(EN-1)-0.5.indd 4