4. Troubleshooting
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections for the Circulation Motor connector.
•
Reconnect the Circulation Motor connector.
2) Check the connections for the Startup Condenser connector of the
Circulation Motor.
•
Reconnect the Startup Condenser connector of the Circulation
Motor.
3) Check the resistance for the Circulation Motor coil.
(Remove the connector before measuring.)
•
Normal: Approx. 14.2 Ω
•
Faulty: Replace the Circulation Motor.
4) Check the operation of the Circulation Motor Relay.
Check the operating voltage between the white wire of the CN101
connector and the red wire of the CN201 connector.
•
Normal: 120V (while operating)
•
Faulty: Replace the Main PBA assy.
•
Normal: Replace the Circulation Motor. Remove Retainer.
•
Remove Retainer.
•
Check voltage
The nozzle does
not inject water.
None
5) Check whether there is foreign material in the water passages.
•
Remove foreign material from the water passages.
4-13