4. Troubleshooting
Error Type
Error mode
Checking Method
Corrective actions
5) Check whether the coil in Inlet Valve is conductive (Remove the
connector before measuring.)
•
Normal: Approx. 1.2 kΩ
•
Faulty: Replace the Inlet Valve.
6) Check whether the Inlet Valve is operating normally.
•
Check the operation of the Inlet Valve
•
Normal: 120V
•
Check the Inlet Valve Relay.
: Check the voltage between the white wire of the Main PBA CN101
connector and the brown wire of the CN201
•
Normal: 120V (while operating)
•
Faulty: Replace the Main PBA assy.
•
Normal: Replace the Inlet Valve
•
Remove Retainer.
•
Check voltage.
7) Check the Power Relay.
•
See the “Power Relay error”.
8) Check whether the water supply stops after water is supplied for 5
seconds.
•
Replace the Flow Meter.
9) Check whether the water supply stops after water is supplied for 1 or
5 minutes.
•
Check the water supply valve and increase the water pressure.
4-5
Copyright© 1995-2010 SAMSUNG. All rights reserved.