4.
Troubleshooting
Error type
Error mode
Checking Method
Corrective actions
Main-PBA DC
Voltage Error
None
1) Check the DC voltage of the Main PBA.
•
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 7 (pink) of the CN302 connector.
•
Normal: 4.5V to 5.5V
•
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 9 (white) of the CN302 connector.
•
Normal (Power Key On): 9.5V to 12.5V
•
Normal (Power Key Off): 5.5V to 7.0V
•
Faulty: Replace the Main-PBA Assy.
•
Remove Retainer.
•
Check voltage (4.5V~5.5V)
•
Check voltage (9.5V~12.5V or 5.5V~7.0V)
Copyright© 1995-2010 SAMSUNG. All rights reserved.
4-12