4. Troubleshooting
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections for the Low Level Sensor connectors.
•
Faulty: Replace the Low Level Sensor, Remove foreign material
from the floater
•
Normal: Replace the Main PBA assy.
•
Reconnect the Low Level Sensor connectors.
Low Level
Water Error
‘Normal’ +
‘Heavy’ +
‘Quick’ LED
•
Faulty: Replace the Low Level Sensor, Remove foreign material
from the floater
•
Normal: Replace the Main PBA assy.
Button error
‘Normal’ +
‘Delicate’ LED
1) Check whether there is condensation on the Main PBA connector
(CN803)
•
Faulty: Remove any condensation and moisture.
•
Normal: Replace the Control Panel assy.
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections of the Heater connectors.
•
Reconnect the Heater connectors.
2) Check the resistance between both ends of the Heater.
: Check the resistance between both ends of the Heater directly, or check
the resistance between the red wire of the Heater Relay and the amber
and yellow wires of the Power Relay, respectively.
•
Normal: Approx. 13Ω
NOTE
Check after disconnect circuit breaker or power cable.
•
Faulty: Replace the Heater.
Heater error
‘Heavy’ +
‘Delicate’ LED
4-7